On-line indirect chemiluminescence detection in capillary electrophoresis

被引:58
作者
Zhang, Y [1 ]
Huang, B [1 ]
Cheng, JK [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary electrophoresis; chemiluminescence; indirect detection; amino acids; catecholamines; catechol;
D O I
10.1016/S0003-2670(98)00018-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis with on-line indirect chemiluminescence detection was firstly used in detecting catecholamines and six amino acids neurotransmitters. The high and constant chemiluminescence background was obtained by the chemiluminescence reaction of luminol-H2O2, enhanced by Co(II). The analytes could complex with Co(II) and reduced the free Co(II) concentration, and thus, the chemiluminescence intensity decreased. The degree of chemiluminescence suppression was a measure of the analytes' concentration. The choice of the catalyst ion, the mixing model of analytes with chemiluminescence reagent, the concentration of H2O2 and Co(II) were discussed. Sodium dodecyl sulfate was used in separating catechol, epinephrine, norepinephrine and dopaminde, with the detection limit of 87, 51, 22, and 38 fmol, respectively. The detection limit for six amino acid is 9, 41, 15, 28, 33, and 250 fmol, respectively, which are 2 orders of magnitude lower than that of HPLC. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 17 条
[1]  
BAEUYENS WRG, 1997, ANAL CHEM, V69, pA83
[2]   DETERMINATION OF CATECHOLAMINES IN SINGLE ADRENAL-MEDULLARY CELLS BY CAPILLARY ELECTROPHORESIS AND LASER-INDUCED NATIVE FLUORESCENCE [J].
CHANG, HT ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1079-1083
[3]   END-COLUMN CHEMILUMINESCENCE DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
DADOO, R ;
SETO, AG ;
COLON, LA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :303-306
[4]   CAPILLARY ELECTROPHORESIS [J].
GORDON, MJ ;
HUANG, XH ;
PENTONEY, SL ;
ZARE, RN .
SCIENCE, 1988, 242 (4876) :224-228
[5]   MICELLE-ENHANCED CHEMI-LUMINESCENCE AND APPLICATION TO THE DETERMINATION OF BIOLOGICAL REDUCTANTS USING LUCIGENIN [J].
HINZE, WL ;
RIEHL, TE ;
SINGH, HN ;
BABA, Y .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :2180-2191
[6]  
HOORN FAJ, 1994, J CHROMATOGR, V563, P348
[7]   On-line chemiluminescence detection for capillary lan analysis [J].
Huang, B ;
Li, JJ ;
Zhang, L ;
Cheng, JK .
ANALYTICAL CHEMISTRY, 1996, 68 (14) :2366-2369
[8]  
KOERNEF PJ, 1987, MIKROCHIM ACTA, V11, P79
[9]   PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY [J].
KWAKMAN, PJM ;
BRINKMAN, UAT .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :175-192
[10]  
LIAO SY, 1995, HRC-J HIGH RES CHROM, V18, P667