Sensor data fusion for responsive high resolution ultrasonic temperature measurement using piezoelectric transducers

被引:10
作者
Hashmi, Anas [1 ]
Kalashnikov, Alexander N. [2 ]
机构
[1] Univ Jeddah, Dept Elect & Elect Engn, Univ Jeddah Rd, Jeddah, Saudi Arabia
[2] Sheffield Hallam Univ, Dept Engn & Maths, Howard Str, Sheffield S1 1WB, S Yorkshire, England
关键词
Ultrasonic instrumentation; Ultrasonic non-destructive evaluation; Ultrasonic oscillating temperature sensor; Data fusion; Temperature sensing; High resolution temperature measurement;
D O I
10.1016/j.ultras.2019.105969
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasonic temperature measurement allows for responsive measurements across an entire ultrasonic pathway, unlike most conventional temperature sensors that respond to the temperature at the point of their placement only after a notable response time. The high cost of required ultrasonic instrumentation can be reduced substantially by using ultrasonic oscillating temperature sensors (UOTS) consisting of inexpensive narrowband piezo transducers and driving electronics. An UOTS produces sustained oscillations at a frequency that relates to the temperature of the medium between the transducers. The existence of thermal hysteresis in UOTS readings, observed experimentally and apparently related to the fundamental properties of piezoelectric materials, makes conversion of the output frequency readings to the temperature values ambiguous. This makes it complicated to calibrate and use UOTS on their own. In the reported experiment (heating, then naturally cooling of a water vessel equipped with both UOTS and conventional sensors), this hysteresis was solved by fusing UOTS data with conventional temperature sensor readings. As the result, the combination of one UOTS plus one conventional reference sensor allowed improving both the temperature resolution and responsiveness of the latter and ambiguity of the readings of the former. Data fusion effectively led to calibrating the UOTS at every change of the conventional sensor's reading, removing any concerns related to the thermal expansion/contraction of the ultrasonic pathway itself and/or hysteresis of piezoelectric transducers.
引用
收藏
页数:8
相关论文
共 25 条
[1]  
Afaneh A., 2012, THESIS
[2]  
Afaneh A., 2011, Physics Research International, P156396, DOI DOI 10.1155/2011/156396
[3]   Ultrasonic Sensing of Temperature of Liquids Using Inexpensive Narrowband Piezoelectric Transducers [J].
Alzebda, Said ;
Kalashnikov, Alexander N. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (12) :2704-2711
[4]  
FILLER RL, 1990, PROCEEDINGS OF THE 44TH ANNUAL SYMPOSIUM ON FREQUENCY CONTROL 1990, P176, DOI 10.1109/FREQ.1990.177495
[5]  
Hashimoto A, 2015, IEEE POW SYST COMP C, P1
[6]  
Hashmi A, 2016, 2016 INTERNATIONAL CONFERENCE FOR STUDENTS ON APPLIED ENGINEERING (ICSAE), P42, DOI 10.1109/ICSAE.2016.7810158
[7]   Embedded Supervisory Control and Output Reporting for the Oscillating Ultrasonic Temperature Sensors [J].
Hashmi, A. ;
Malakoutikhah, M. ;
Light, R. A. ;
Kalashnikov, A. N. .
INTELLIGENT SYSTEMS IN CYBERNETICS AND AUTOMATION THEORY, VOL 2, 2015, 348 :139-150
[8]  
Hashmi A., 2015, P 8 SAUD STUD C UK W, P525, DOI [10.1142/9781783269150_0044, DOI 10.1142/9781783269150_0044]
[9]  
Hashmi A., 2017, 5 INT C ADV INF SYST, P58
[10]  
Ihara Ikuo, 2009, 2009 IEEE International Ultrasonics Symposium, P1199, DOI 10.1109/ULTSYM.2009.5441882