Adherence to the bowel cleansing regimen for pan-enteric capsule endoscopy in patients with suspected Crohn's disease and factors affecting the image quality

被引:3
作者
Brodersen, Jacob Broder [1 ,2 ]
Andersen, Karina Winther [3 ]
Jensen, Michael Dam [3 ]
机构
[1] Hosp South West Jutland, Dept Internal Med, Sect Gastroenterol, Esbjerg, Denmark
[2] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
[3] Lillebaelt Hosp, Dept Internal Med, Sect Gastroenterol, Vejle, Denmark
关键词
Crohn's disease; capsule endoscopy; bowel cleansing; PILLCAM COLON CAPSULE; EUROPEAN-SOCIETY; SAFETY;
D O I
10.1080/00365521.2021.2016945
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective Pan-enteric capsule endoscopy (CE) is an attractive diagnostic approach in patients examined for Crohn's disease (CD). The aim of this study was to examine the adherence to the recommended bowel cleansing regimen and determine clinical factors affecting the image quality. Methods In a prospective blinded trial, patients with suspected CD were examined with the PillCam Crohn's capsule after bowel preparation with 2 + 2 L of polyethylene glycol (PEG) and sodium phosphate booster. The image quality was graded on a four-point scale. A good or excellent image quality defined a diagnostic procedure. Results Fifty-nine patients participated. The mean volume of PEG was 2.5 L (CI 2.3-2.8). Ten patients (17%) were able to drink all 4 L of PEG, and 44 patients (75%) ingested >= 2 L. The image quality was poor, fair, good or excellent in 0%, 29.3%, 29.3% and 41.4%, respectively. The mean volume of PEG was 1.9 L (CI 1.4-2.4), 2.2 L (CI 1.8-2.7) and 3.2 L (CI 2.8-3.5) in patients with a fair, good or excellent image quality (p < .001). In a regression analysis, only the volume of PEG was associated with the obtained image quality (r(s)=0.52; p < .001). The diagnostic yield was equal in patients with a diagnostic or non-diagnostic procedure (43.9% and 47.1%, respectively). Conclusions In patients examined with pan-enteric CE for suspected CD, the volume of PEG is the major factor affecting the image quality. Although few patients are able to ingest the recommended volume, the diagnostic yield is not affected.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 22 条
[1]   European evidence based consensus for endoscopy in inflammatory bowel disease [J].
Annese, Vito ;
Daperno, Marco ;
Rutter, Matthew D. ;
Amiot, Aurelien ;
Bossuyt, Peter ;
East, James ;
Ferrante, Marc ;
Goetz, Martin ;
Katsanos, Konstantinos H. ;
Kiesslich, Ralf ;
Ordas, Ingrid ;
Repici, Alessandro ;
Rosa, Bruno ;
Sebastian, Shaji ;
Kucharzik, Torsten ;
Eliakim, Rami .
JOURNAL OF CROHNS & COLITIS, 2013, 7 (12) :982-1018
[2]   Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn's disease: a multicentre, prospective study [J].
Bruining, David Henry ;
Oliva, Salvatore ;
Fleisher, Mark R. ;
Fischer, Monika ;
Fletcher, Joel G. .
BMJ OPEN GASTROENTEROLOGY, 2020, 7 (01)
[3]   Safety and Feasibility of Using the Second-Generation Pillcam Colon Capsule to Assess Active Colonic Crohn's Disease [J].
D'Haens, Geert ;
Lowenberg, Mark ;
Samaan, Mark A. ;
Franchimont, Denis ;
Ponsioen, Cyriel ;
van den Brink, Gijs R. ;
Fockens, Paul ;
Bossuyt, Peter ;
Amininejad, Leila ;
Rajamannar, Gopalan ;
Lensink, Elsemieke M. ;
Van Gossum, Andre M. .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (08) :1480-+
[4]   Guidelines for sedation and anesthesia in GI endoscopy [J].
Early, Dayna S. ;
Lightdale, Jenifer R. ;
Vargo, John J., II ;
Acosta, Ruben D. ;
Chandrasekhara, Vinay ;
Chathadi, Krishnavel V. ;
Evans, John A. ;
Fisher, Deborah A. ;
Fonkalsrud, Lisa ;
Hwang, Joo Ha ;
Khashab, Mouen A. ;
Muthusamy, V. Raman ;
Pasha, Shabana F. ;
Saltzman, John R. ;
Shergill, Amandeep K. ;
Cash, Brooks D. ;
DeWitt, John M. .
GASTROINTESTINAL ENDOSCOPY, 2018, 87 (02) :327-337
[5]   Clinical Benefit of Capsule Endoscopy in Crohn's Disease: Impact on Patient Management and Prevalence of Proximal Small Bowel Involvement [J].
Hansel, Stephanie L. ;
McCurdy, Jeffrey D. ;
Barlow, John M. ;
Fidler, Jeff ;
Fletcher, Joel G. ;
Becker, Brenda ;
Prabhu, Nayantara Coelho ;
Faubion, William A. ;
Hanson, Karen A. ;
Kane, Sunanda V. ;
Kisiel, John B. ;
Loftus, Edward V., Jr. ;
Papadakis, Konstantinos A. ;
Pardi, Darrell S. ;
Raffals, Laura E. ;
Schoenoff, Shayla ;
Tremaine, William J. ;
Bruining, David H. .
INFLAMMATORY BOWEL DISEASES, 2018, 24 (07) :1582-1588
[6]   A pilot study evaluating a new low-volume colon cleansing procedure for capsule colonoscopy [J].
Hartmann, D. ;
Keuchel, M. ;
Philipper, M. ;
Gralnek, I. M. ;
Jakobs, R. ;
Hagenmueller, F. ;
Neuhaus, H. ;
Riemann, J. F. .
ENDOSCOPY, 2012, 44 (05) :482-486
[7]   Diagnostic Accuracy of Capsule Endoscopy for Small Bowel Crohn's Disease Is Superior to That of MR Enterography or CT Enterography [J].
Jensen, Michael Dam ;
Nathan, Torben ;
Rafaelsen, Soren Rafael ;
Kjeldsen, Jens .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2011, 9 (02) :124-129
[8]   New reduced volume preparation regimen in colon capsule endoscopy [J].
Kakugawa, Yasuo ;
Saito, Yutaka ;
Saito, Shoichi ;
Watanabe, Kenji ;
Ohmiya, Naoki ;
Murano, Mitsuyuki ;
Oka, Shiro ;
Arakawa, Tetsuo ;
Goto, Hidemi ;
Higuchi, Kazuhide ;
Tanaka, Shinji ;
Ishikawa, Hideki ;
Tajiri, Hisao .
WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (17) :2092-2098
[9]   Small Bowel Capsule Endoscopy in the Management of Established Crohn's Disease: Clinical Impact, Safety, and Correlation with Inflammatory Biomarkers [J].
Kopylov, Uri ;
Nemeth, Artur ;
Koulaouzidis, Anastasios ;
Makins, Richard ;
Wild, Gary ;
Afif, Waqqas ;
Bitton, Alain ;
Johansson, Gabriele Wurm ;
Bessissow, Talat ;
Eliakim, Rami ;
Toth, Ervin ;
Seidman, Ernest G. .
INFLAMMATORY BOWEL DISEASES, 2015, 21 (01) :93-100
[10]   Capsule Endoscopy Structured Terminology (CEST): Proposal of a standardized and structured terminology for reporting capsule endoscopy procedures [J].
Korman, LY ;
Delvaux, M ;
Gay, G ;
Hagenmuller, F ;
Keuchel, M ;
Friedman, S ;
Weinstein, M ;
Shetzline, M ;
Cave, D ;
de Franchis, R .
ENDOSCOPY, 2005, 37 (10) :951-959