Ovipositor-inspired steerable needle: design and preliminary experimental evaluation

被引:30
作者
Scali, M. [1 ]
Pusch, T. P. [2 ]
Breedveld, P. [1 ]
Dodou, D. [1 ]
机构
[1] Delft Univ Technol, Biomech Dept, Fac Mech Maritime & Mat Engn, Delft, Netherlands
[2] Fraunhofer Inst Mfg Engn & Automat, Fraunhofer Project Grp Automat Med & Biotechnol, Mannheim, Germany
关键词
medical needles; steerable needles; percutaneous procedures; biologically inspired; solid organs; TORSIONAL DYNAMICS; DEFLECTION; CURVATURE; PROBE; INSERTION; SURFACES;
D O I
10.1088/1748-3190/aa92b9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Flexible steerable needles have the potential to allow surgeons to reach deep targets inside the human body with higher accuracy than rigid needles do. Furthermore, by maneuvering around critical anatomical structures, steerable needles could limit the risk of tissue damage. However, the design of a thin needle (e.g. diameter under 2 mm) with a multi-direction steering mechanism is challenging. The goal of this paper is to outline the design and experimental evaluation of a biologically inspired needle with a diameter under 2 mm that advances through straight and curved trajectories in a soft substrate without being pushed, without buckling, and without the need of axial rotation. The needle design, inspired by the ovipositor of parasitoid wasps, consisted of seven nickel titanium wires and had a total diameter of 1.2 mm. The motion of the needle was tested in gelatin phantoms. Forward motion of the needle was evaluated based on the lag between the actual and the desired insertion depth of the needle. Steering was evaluated based on the radius of curvature of a circle fitted to the needle centerline and on the ratio of the needle deflection from the straight path to the insertion depth. The needle moved forward inside the gelatin with a lag of 0.21 (single wire actuation) and 0.34 (double wire actuation) and achieved a maximum curvature of 0.0184 cm(-1) and a deflection-to-insertion ratio of 0.0778. The proposed biologically inspired needle design is a relevant step towards the development of thin needles for percutaneous interventions.
引用
收藏
页数:17
相关论文
共 81 条
[1]   Minimization of needte deflection in robot-assisted percutaneous therapy [J].
Abolhassani, Niki ;
Patel, Rajni V. ;
Ayazi, Farzam .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (02) :140-148
[2]   Methods for Improving the Curvature of Steerable Needles in Biological Tissue [J].
Adebar, Troy K. ;
Greer, Joseph D. ;
Laeseke, Paul F. ;
Hwang, Gloria L. ;
Okamura, Allison M. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (06) :1167-1177
[3]  
Alterovitz R, 2003, STUD HEALTH TECHNOL, V94, P19
[4]  
Ayvali E, 2014, SPRINGER TRACTS ADV, V79, P115
[5]   A novel curvature-controllable steerable needle for percutaneous intervention [J].
Bui, Van Khuyen ;
Park, Sukho ;
Park, Jong-Oh ;
Ko, Seong Young .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (08) :727-738
[6]   Multi-target Planar Needle Steering with a Bio-inspired Needle Design [J].
Burrows, Christopher ;
Liu, Fangde ;
Leibinger, Alexander ;
Secoli, Riccardo ;
Rodriguez y Baena, Ferdinando .
ADVANCES IN ITALIAN MECHANISM SCIENCE, 2017, 47 :51-60
[7]  
Burrows C, 2013, 2013 13TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2013), P1252, DOI 10.1109/ICCAS.2013.6704141
[8]   Fifty years of brain tissue mechanical testing: From in vitro to in vivo investigations [J].
Chatelin, Simon ;
Constantinesco, Andre ;
Willinger, Remy .
BIORHEOLOGY, 2010, 47 (5-6) :255-276
[9]   DEFLECTION OF SPINAL NEEDLES BY THE BEVEL [J].
DRUMMOND, GB ;
SCOTT, DHT .
ANAESTHESIA, 1980, 35 (09) :854-857
[10]   Development and Validation of a Numerical Model for Cross-section Optimization of a Multi-Part Probe for Soft Tissue Intervention [J].
Frasson, L. ;
Neubert, J. ;
Reina, S. ;
Oldfield, M. ;
Davies, B. L. ;
Rodriguez y Baena, F. .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :3202-3205