Organic and inorganic selenium speciation in environmental and biological samples by nanometer-sized materials packed dual-column separation/preconcentration on-line coupled with ICP-MS

被引:39
作者
Huang, Chaozhang [1 ]
Hu, Bin [1 ]
He, Man [1 ]
Duan, Jiankun [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
来源
JOURNAL OF MASS SPECTROMETRY | 2008年 / 43卷 / 03期
关键词
nanometer-sized Al2O3; DMSA modified mesoporous TiO2; on-line dual-column separation/preconcentration; speciation of selenium; ICP-MS;
D O I
10.1002/jms.1321
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel, fast, and cheap nonchromatographic method for direct speciation of dissolved inorganic and organic selenium species in environmental and biological samples was developed by flow injection (FI) dual-column preconcentration/separation on-line coupled with ICP-MS determination. In the developed technique, the first column packed with nanometer-sized Al2O3 could selectively adsorb the inorganic selenium [Se(IV), Se(VI)], and the retained inorganic selenium could be eluted by 0.2 mol l(-1) NaOH, while the organic Se [selenocystine (SeCys(2)) and selenomethionine (Se-Met)] was not retained. On the other hand, the second column packed with mesoporous TiO2 chemically modified by dimercaptosuccinic acid (DMSA) could selectively adsorb Se(IV) and SeCys(2) and barely adsorb Se(VI) and Se-Met. When the sample solution was passed through the column 1, separation of inorganic selenium and organic selenium could be achieved first. Then, the effluent from column I was successively introduced into the column 2 and the speciation of organic selenium could be attained due to the different adsorption behaviors of Se-Met and SeCys(2) on DMSA modified TiO2. After that, the eluent from column 1 contained Se(IV), and Se(VI) was adjusted to desired pH and injected into column 2, and the speciation of Se(IV) and Se(VI) could also be realized thanks to their different retention on column 2. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. The detection limits obtained for Se(IV), Se(VI), Se-Met and SeCys(2) were 45-210 ng l(-1) with precisions of 3.6-9.7%. The proposed method has been successfully applied for the speciation of dissolved inorganic and organic selenium in environmental and biological samples. In order to validate the methodology, the developed method was also applied to the speciation of selenium in certified reference material of SELM-1 yeast, and the determined values were in good agreement with the certified values. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:336 / 345
页数:10
相关论文
共 47 条
  • [1] Preconcentration of selenium compounds on a porous graphitic carbon column in view of HPLC-ICP-AES speciation analysis
    Abbas-Ghaleb, K
    Gilon, N
    Crétier, G
    Mermet, JM
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (06) : 1026 - 1031
  • [2] Selenium and cancer: Some nutritional aspects
    Alaejos, MS
    Romero, FJD
    Romero, CD
    [J]. NUTRITION, 2000, 16 (05) : 376 - 383
  • [3] Selenium and interleukins in persons infected with human immunodeficiency virus type 1
    Baum, MK
    Miguez-Burbano, MJ
    Campa, A
    Shor-Posner, G
    [J]. JOURNAL OF INFECTIOUS DISEASES, 2000, 182 : S69 - S73
  • [4] BERTOLINO FA, 2006, ANAL CHIMICA AC, V14, P32
  • [5] Speciation of selenium and tellurium in milk by hydride generation atomic fluorescence spectrometry
    Cava-Montesinos, P
    de la Guardia, A
    Teutsch, C
    Cervera, ML
    de la Guardia, M
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (05) : 696 - 699
  • [6] Cloud point extraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the speciation of inorganic selenium in environmental water samples
    Chen, Beibei
    Hu, Bin
    He, Man
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (19) : 2894 - 2900
  • [7] An analysis of cancer prevention by selenium
    Combs, GF
    Clark, LC
    Turnbull, BW
    [J]. BIOFACTORS, 2001, 14 (1-4) : 153 - 159
  • [8] Development of a new liquid chromatography method for the separation and speciation of organic and inorganic selenium compounds via particle beam-hollow cathode glow discharge-optical emission spectroscopy
    Davis, WC
    Jin, FX
    Dempster, MA
    Robichaud, JL
    Marcus, RK
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (02) : 99 - 103
  • [9] Separation and detection of Se-compounds by ion pairing liquid chromatography-microwave assisted hydride generation-atomic fluorescence spectrometry
    Dumont, E
    De Cremer, K
    Van Hulle, M
    Chéry, CC
    Vanhaecke, F
    Cornelis, R
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) : 167 - 171
  • [10] An ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique combined with a sol-gel process for selective solid-phase extraction of cadmium(II)
    Fang, GZ
    Tan, J
    Yan, XP
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (06) : 1734 - 1739