Transcatheter aortic valve implantation with the ACURATE neo valve: indications, procedural aspects and clinical outcomes

被引:22
作者
Kim, Won-Keun [1 ,2 ,3 ]
Hengstenberg, Christian [4 ]
Hilker, Michael [5 ]
Schaefer, Ulrich [6 ]
Rudolph, Tanja K. [7 ]
Toggweiler, Stefan [8 ]
Rueck, Andreas [9 ]
Sondergaard, Lars [10 ]
Conradi, Lenard [11 ]
Hamm, Christian [13 ]
Walther, Thomas [12 ]
Moellmann, Helge [13 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, Benekestr 2-8, D-61231 Bad Nauheim, Germany
[2] Kerckhoff Heart Ctr, Dept Cardiac Surg, Bad Nauheim, Germany
[3] Justus Liebig Univ Giessen, Dept Cardiol, Giessen, Germany
[4] Univ Dept MedUni, Dept Med 2, Vienna, Austria
[5] Univ Med Ctr, Dept Cardiothorac Surg, Regensburg, Germany
[6] Marien Hosp, Dept Cardiol Angiol & Intens Care Med, Hamburg, Germany
[7] Ruhr Univ Bochum, Dept Cardiol, Herz & Diabet Zentrum NRW, Bad Oeynhausen, Germany
[8] Luzerner Kantonsspital, Heart Ctr Lucerne, Luzern, Switzerland
[9] Karolinska Univ Hosp, Stockholm, Sweden
[10] Rigshosp, Heart Ctr, Copenhagen, Denmark
[11] Univ Hosp Hamburg Eppendorf UKE, Univ Heart Ctr, Dept Cardiovasc Surg, Hamburg, Germany
[12] Goethe Univ Frankfurt, Univ Heart Ctr, Dept Cardiovasc Surg, Frankfurt, Germany
[13] St Johannes Hosp, Dept Cardiol, Dortmund, Germany
关键词
aortic stenosis; TAVI; training and education; HEART-VALVE; MULTICENTER;
D O I
10.4244/EIJ-D-19-00908
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The ACURATE neo aortic valve system is a self-expanding transcatheter device that was granted CE mark in 2014 and has since been widely adopted in the treatment of patients with severe aortic stenosis. The ACURATE neo can be used in a wide clinical spectrum, but there are some specific indications and anatomies where this device is particularly suitable. Recently, it was shown that, with appropriate patient screening, size selection, and optimised positioning, results can be improved substantially. This review provides an overview of existing data and compiles a standardised manual of best practice for the implantation of this device based on both evidence and individual experience.
引用
收藏
页码:E1571 / +
页数:16
相关论文
共 15 条
[1]   Outcomes of three different new generation transcatheter aortic valve prostheses [J].
Costa, Giuliano ;
Buccheri, Sergio ;
Barbanti, Marco ;
Picci, Andrea ;
Todaro, Denise ;
Di Simone, Emanuela ;
La Spina, Ketty ;
D'Arrigo, Paolo ;
Criscione, Enrico ;
Nastasi, Marco ;
Sgroi, Carmelo ;
Tamburino, Corrado .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (03) :398-407
[2]   Transcatheter Valve SELECTion in Patients With Right Bundle Branch Block and Impact on Pacemaker Implantations [J].
Husser, Oliver ;
Pellegrini, Costanza ;
Kim, Won-Keun ;
Holzamer, Andreas ;
Pilgrim, Thomas ;
Toggweiler, Stefan ;
Schaefer, Ulrich ;
Blumenstein, Johannes ;
Deuschl, Florian ;
Rheude, Tobias ;
Joner, Michael ;
Hilker, Michael ;
Hengstenberg, Christian ;
Moellmann, Helge .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (18) :1781-1793
[3]   Multicenter Comparison of Novel Self-Expanding Versus Balloon-Expandable Transcatheter Heart Valves [J].
Husser, Oliver ;
Kim, Won-Keun ;
Pellegrini, Costanza ;
Holzamer, Andreas ;
Walther, Thomas ;
Mayr, Patrick N. ;
Joner, Michael ;
Kasel, Albert M. ;
Trenkwalder, Teresa ;
Michel, Jonathan ;
Rheude, Tobias ;
Kastrati, Adnan ;
Schunkert, Heribert ;
Burgdorf, Christof ;
Hilker, Michael ;
Moellmann, Helge ;
Hengstenberg, Christian .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (20) :2078-2087
[4]   Transfemoral implantation of the ACURATE neo prosthesis using a low-profile expandable introducer system: A multicenter registry [J].
Kim, Won-Keun ;
Brinkert, Miriam ;
Mangner, Norman ;
Gatto, Fernando ;
Husser, Oliver ;
Renker, Matthias ;
Liebetrau, Christoph ;
Gasior, Tomasz ;
Doss, Mirko ;
Walther, Thomas ;
Hamm, Christian ;
Linke, Axel ;
Toggweiler, Stefan ;
Moellmann, Helge .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 281 :76-81
[5]   The ACURATE neo Transcatheter Heart Valve A Comprehensive Analysis of Predictors of Procedural Outcome [J].
Kim, Won-Keun ;
Moellmann, Helge ;
Liebetrau, Christoph ;
Renker, Matthias ;
Rolf, Andreas ;
Simon, Philippe ;
Van Linden, Arnaud ;
Arsalan, Mani ;
Doss, Mirko ;
Hamm, Christian W. ;
Walther, Thomas .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (17) :1721-1729
[6]   Transfemoral aortic valve implantation using a self-expanding transcatheter heart valve without pre-dilation [J].
Kim, Won-Keun ;
Liebetrau, Christoph ;
Renker, Matthias ;
Rolf, Andreas ;
Van Linden, Arnaud ;
Arsalan, Mani ;
Husser, Oliver ;
Moellmann, Helge ;
Hamm, Christian ;
Walther, Thomas .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 243 :156-160
[7]   Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial [J].
Lanz, Jonas ;
Kim, Won-Keun ;
Walther, Thomas ;
Burgdorf, Christof ;
Mollmann, Helge ;
Linke, Axel ;
Redwood, Simon ;
Thilo, Christian ;
Hilker, Michael ;
Joner, Michael ;
Thiele, Holger ;
Conzelmann, Lars ;
Conradi, Lenard ;
Kerber, Sebastian ;
Schymik, Gerhard ;
Prendergast, Bernard ;
Husser, Oliver ;
Stortecky, Stefan ;
Heg, Dik ;
Juni, Peter ;
Windecker, Stephan ;
Pilgrim, Thomas .
LANCET, 2019, 394 (10209) :1619-1628
[8]   Transcatheter aortic valve implantation using the ACURATE neo in bicuspid and tricuspid aortic valve stenosis: a propensity-matched analysis of a European experience [J].
Mangieri, Antonio ;
Chieffo, Alaide ;
Won-Keun, Kim ;
Stefanini, Giulio G. ;
Rescigno, Giuseppe ;
Barbanti, Marco ;
Tamburino, Corrado ;
Ruck, Andreas ;
Pagnesi, Matteo ;
Linder, Rickard ;
Toggweiler, Stefan ;
Montorfano, Matteo ;
Colombo, Antonio .
EUROINTERVENTION, 2018, 14 (12) :E1269-E1275
[9]   Short-Term Outcome and Hemodynamic Performance of Next-Generation Self-Expanding Versus BalloonExpandable Transcatheter Aortic Valves in Patients With Small Aortic Annulus A Multicenter Propensity-Matched Comparison [J].
Mauri, Victor ;
Kim, Won K. ;
Abumayyaleh, Mohammad ;
Walther, Thomas ;
Moellmann, Helge ;
Schaefer, Ulrich ;
Conradi, Lenard ;
Hengstenberg, Christian ;
Hilker, Michael ;
Wahlers, Thorsten ;
Baldus, Stephan ;
Rudolph, Volker ;
Madershahian, Navid ;
Rudolph, Tanja K. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (10)
[10]   Real-world experience using the ACURATE neo prosthesis: 30-day outcomes of 1,000 patients enrolled in the SAVI TF registry [J].
Moellmann, Helge ;
Hengstenberg, Christian ;
Hilker, Michael ;
Kerber, Sebastian ;
Schaefer, Ulrich ;
Rudolph, Tanja ;
Linke, Axel ;
Franz, Norbert ;
Kuntze, Thomas ;
Nef, Holger ;
Kappert, Utz ;
Walther, Thomas ;
Zembala, Michael O. ;
Toggweiler, Stefan ;
Kim, Won-Keun .
EUROINTERVENTION, 2018, 13 (15) :1764-1770