Echocardiographic Evaluation of Patent Foramen Ovale Prior to Device Closure

被引:94
作者
Rana, Bushra S. [1 ]
Thomas, Martyn R. [3 ]
Calvert, Patrick A. [1 ,2 ]
Monaghan, Mark J. [4 ]
Hildick-Smith, David [5 ]
机构
[1] Natl Hlth Serv Fdn Trust, Papworth Hosp, Cambridge CB23 3RE, England
[2] Univ Cambridge, Cambridge CB2 1TN, England
[3] St Thomas Hosp, London, England
[4] Kings Coll Hosp London, London, England
[5] Royal Sussex Cty Hosp, Brighton BN2 5BE, E Sussex, England
关键词
transesophageal echocardiography; patent foramen ovale closure; contrast; three dimensions; TO-LEFT SHUNT; CONTRAST ECHOCARDIOGRAPHY; TRANSCATHETER CLOSURE; ISCHEMIC-STROKE; OUTCOMES;
D O I
10.1016/j.jcmg.2010.01.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High-quality imaging of the atrial septum has never been so relevant to the adult cardiologist. This article focuses on the role of echocardiography in the evaluation of patent foramen ovale for closure. It provides a systematic and comprehensive approach to transesophageal echocardiographic study in such a patient. The salient information required for planning the device and equipment needed for the closure procedure are discussed. (J Am Coll Cardiol Img 2010;3:749-60) (c) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:749 / 760
页数:12
相关论文
共 27 条
[1]   CLASSIFICATION OF SUBTYPE OF ACUTE ISCHEMIC STROKE - DEFINITIONS FOR USE IN A MULTICENTER CLINICAL-TRIAL [J].
ADAMS, HP ;
BENDIXEN, BH ;
KAPPELLE, LJ ;
BILLER, J ;
LOVE, BB ;
GORDON, DL ;
MARSH, EE ;
KASE, CS ;
WOLF, PA ;
BABIKIAN, VL ;
LICATAGEHR, EE ;
ALLEN, N ;
BRASS, LM ;
FAYAD, PB ;
PAVALKIS, FJ ;
WEINBERGER, JM ;
TUHRIM, S ;
RUDOLPH, SH ;
HOROWITZ, DR ;
BITTON, A ;
MOHR, JP ;
SACCO, RL ;
CLAVIJO, M ;
ROSENBAUM, DM ;
SPARR, SA ;
KATZ, P ;
KLONOWSKI, E ;
CULEBRAS, A ;
CAREY, G ;
MARTIR, NI ;
FICARRA, C ;
HOGAN, EL ;
CARTER, T ;
GURECKI, P ;
MUNTZ, BK ;
RAMIREZLASSEPAS, M ;
TULLOCH, JW ;
QUINONES, MR ;
MENDEZ, M ;
ZHANG, SM ;
ALA, T ;
JOHNSTON, KC ;
ANDERSON, DC ;
TARREL, RM ;
NANCE, MA ;
BUDLIE, SR ;
DIERICH, M ;
HELGASON, CM ;
HIER, DB ;
SHAPIRO, RA .
STROKE, 1993, 24 (01) :35-41
[2]   Antithrombotic and thrombolytic therapy for ischemic stroke [J].
Albers, GW ;
Amarenco, P ;
Easton, JD ;
Sacco, RL ;
Teal, P .
CHEST, 2004, 126 (03) :483S-512S
[3]  
Anderson RH, 1999, CLIN ANAT, V12, P362, DOI 10.1002/(SICI)1098-2353(1999)12:5<362::AID-CA6>3.0.CO
[4]  
2-F
[5]   Development and structure of the atrial septum [J].
Anderson, RH ;
Brown, NA ;
Webb, S .
HEART, 2002, 88 (01) :104-110
[6]   Potential source of cerebral embolism in migraine with aura - A transcranial Doppler study [J].
Anzola, GP ;
Magoni, M ;
Guindani, M ;
Rozzini, L ;
Dalla Volta, G .
NEUROLOGY, 1999, 52 (08) :1622-1625
[7]   Real-time three-dimensional transoesophageal echocardiography for guidance of non-coronary interventions in the catheter laboratory [J].
Balzer, Jan ;
Kelm, Malte ;
Kuehl, Harald P. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (03) :341-349
[8]   Transcatheter closure of patent foramen ovale in patients with cerebral ischemia [J].
Braun, MU ;
Fassbender, D ;
Schoen, SP ;
Haass, M ;
Schraeder, R ;
Scholtz, W ;
Strasser, RH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (12) :2019-2025
[9]   Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder [J].
Divekar, A ;
Gaamangwe, T ;
Shaikh, N ;
Raabe, M ;
Ducas, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) :1213-1218
[10]   Use of Saline Contrast Echo Timing to Distinguish Intracardiac and Extracardiac Shunts: Failure of the 3- to 5-Beat Rule [J].
Freeman, Jonathan A. ;
Woods, Timothy D. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (10) :1127-1130