LOW-INTENSITY/HIGH-DENSITY SUBTHRESHOLD MICROPULSE DIODE LASER FOR CHRONIC CENTRAL SEROUS CHORIORETINOPATHY

被引:56
|
作者
Malik, Khurram J. [1 ]
Sampat, Kapil M. [1 ]
Mansouri, Azad [1 ]
Steiner, Joshua N. [1 ]
Glaser, Bert M. [1 ]
机构
[1] Natl Retina Inst, Towson, MD 21204 USA
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2015年 / 35卷 / 03期
关键词
MicroPulse; subthreshold; laser; central serous chorioretinopathy; INTRAVITREAL BEVACIZUMAB; PHOTOCOAGULATION;
D O I
10.1097/IAE.0000000000000285
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the visual outcomes and macular thickness change in patients with symptomatic chronic central serous chorioretinopathy after treatment with a subthreshold MicroPulse diode laser. Methods: In this retrospective, interventional case series, 10 patients were treated with the subthreshold 810-nm diode MicroPulse laser. Selected patients had symptomatic disease that may or may not have involved the foveal center. The MicroPulse laser was applied to the areas of leakage seen on fluorescein angiogram, over the areas of clinical neurosensory detachment, and/or pigment epithelial detachments. Pretreatment and posttreatment vision, change in maximum macular thickness, number of treatment sessions, and number of laser spot applications were recorded. Patients were excluded if they did not attend follow-up, had other confounding macular diseases, were using steroid medications, or application of another treatment modality had been used (i.e., photodynamic therapy or anti-vascular endothelial growth factor medication). Results: Ten patients met the inclusion criteria, with 1 patient treated in both eyes. Three patients were excluded for lack of follow-up, one for the use of systemic steroids, and one for treatment with anti-vascular endothelial growth factor injection. Maximum macular thickness decreased after subthreshold MicroPulse laser treatment between 20 mu m and 338 mu m (mean = 97 mu m decrease, P = 0.0046) in 11 treated eyes. Conclusion: Subthreshold diode MicroPulse laser is a potential treatment option for patients with symptomatic chronic central serous chorioretinopathy.
引用
收藏
页码:532 / 536
页数:5
相关论文
共 50 条
  • [21] Morphological parameters predicting subthreshold micropulse laser effectiveness in central serous chorioretinopathy
    Peter Kiraly
    Jaka Smrekar
    Polona Jaki Mekjavić
    Lasers in Medical Science, 2022, 37 : 3129 - 3136
  • [22] Evaluation of changes in macular structures after subthreshold micropulse laser therapy on chronic central serous chorioretinopathy
    Liu, Lijun
    Xu, Qian
    Song, Xian
    Zhao, Yuqing
    Zhang, Yu
    Qu, Yi
    LASERS IN MEDICAL SCIENCE, 2024, 39 (01)
  • [23] Low-Fluence Photodynamic Therapy versus Subthreshold Micropulse Yellow Wavelength Laser in the Treatment of Chronic Central Serous Chorioretinopathy
    Ozmert, Emin
    Demirel, Sibel
    Yanik, Ozge
    Batioglu, Figen
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [24] OCT biomarkers related to subthreshold micropulse laser treatment effect in central serous chorioretinopathy
    Fang Zheng
    Jingliang He
    Zhitao Su
    Ye Liu
    Yufeng Xu
    Lei Liu
    Panpan Ye
    BMC Ophthalmology, 22
  • [25] OCT biomarkers related to subthreshold micropulse laser treatment effect in central serous chorioretinopathy
    Zheng, Fang
    He, Jingliang
    Su, Zhitao
    Liu, Ye
    Xu, Yufeng
    Liu, Lei
    Ye, Panpan
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [26] Crossover to 689 nm laser therapy after poor responsiveness to subthreshold micropulse laser for chronic central serous chorioretinopathy
    Zhang, Yue
    Wang, Jianing
    Zhang, Jinrong
    Song, Shuang
    Gu, Xiaoya
    Yu, Xiaobing
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2024, 50
  • [27] Subthreshold micropulse yellow laser (577 nm) in chronic central serous chorioretinopathy: safety profile and treatment outcome
    Yadav, N. K.
    Jayadev, C.
    Mohan, A.
    Vijayan, P.
    Battu, R.
    Dabir, S.
    Shetty, B.
    Shetty, R.
    EYE, 2015, 29 (02) : 258 - 264
  • [28] Subthreshold Micropulse Laser vs. Conventional Laser for Central Serous Chorioretinopathy: A Randomized Controlled Clinical Trial
    Zhou, Lijun
    Lai, Kunbei
    Jin, Ling
    Huang, Chuangxin
    Xu, Fabao
    Gong, Yajun
    Li, Longhui
    Zhu, Zhe
    Lu, Lin
    Jin, Chenjin
    FRONTIERS IN MEDICINE, 2021, 8
  • [29] Short-term efficacy of subthreshold micropulse yellow laser (577-nm) photocoagulation for chronic central serous chorioretinopathy
    Kim, Ju Young
    Park, Han Sang
    Kim, Si Yeol
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (12) : 2129 - 2135
  • [30] 577 nm subthreshold micropulse laser treatment for acute central serous chorioretinopathy: a comparative study
    Long, He
    Liu, Maoxiong
    Hu, Qinghua
    Li, Xin
    BMC OPHTHALMOLOGY, 2022, 22 (01)