In vivo EBT radiochromic film dosimetry of electron beam for Total Skin Electron Therapy (TSET)

被引:34
作者
Bufacchi, A.
Carosi, A.
Adorante, N.
delle Canne, S.
Malatesta, T.
Capparella, R.
Fragomeni, R.
Bonanni, A.
Leone, M.
Marmiroli, L.
Begnozzi, L.
机构
[1] Ospedale S Giovanni Calibita Fatebenefratelli, AFaR UOC, Fis Sanitaria, I-00186 Rome, Italy
[2] Ospedale S Giovanni Calibita Fatebenefratelli, Radioterapia, AFaR UOC, I-00186 Rome, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2007年 / 23卷 / 02期
关键词
EBT film; radiochromic film; scanner; Total Skin Electron Therapy; IRRADIATION;
D O I
10.1016/j.ejmp.2007.03.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
EBT radiochromic films were used to determine skin-dose maps for patients undergone Total Skin Electron Therapy (TSET). Gafchromic EBT radiochromic film is one of the newest radiation-induced auto-developing photon and electron-beam analysis films available for therapeutic radiation dosimetry in radiotherapy applications. EBT films can be particularly useful in TSET; due to patient morphology, underdosed regions typically occur, and the radiochromic film represents a suitable candidate for monitoring them. In this study, TSET was applied to treat cutaneous T-cell lymphoma. The technique for TSET was implemented by using an electron beam with a nominal energy of 6 MeV. The patient was treated in a standing position using dual angled fields in order to obtain the greatest dose uniformity along the patient's Longitudinal axis. The electron beam energy was degraded by a PMMA filter. The in vivo dose distribution was determined through the use of EBT films, as well as of thermoluminescent dosimeters for comparison (TLDs). EBT results showed a reasonable agreement with TLDs data. (c) 2007 Published by Elsevier Ltd on behalf of Associazione Italiana di Fisica Medica.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 23 条
[1]  
*AAPM TASK GROUP, 1988, 23 TOT SKIN EL THER
[2]   Utilization of thermoluminescent dosimetry in total skin electron beam radiotherapy of mycosis fungoides [J].
Antolak, JA ;
Cundiff, JH ;
Ha, CS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (01) :101-108
[3]  
Baker J, 2004, MED PHYS, V31, P1726
[4]   ELECTRON-BEAM THERAPY OF MYCOSIS-FUNGOIDES [J].
BLASKO, J ;
BECKER, L ;
GRIFFIN, TW ;
TONG, DYK ;
GROUDINE, M .
ACTA RADIOLOGICA ONCOLOGY, 1979, 18 (04) :321-325
[5]   Absorption spectra variations of EBT radiochromic film from radiation exposure [J].
Butson, MJ ;
Cheung, T ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) :N135-N140
[6]   Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies [J].
Chiu-Tsao, ST ;
Ho, Y ;
Shankar, R ;
Wang, L ;
Harrison, LB .
MEDICAL PHYSICS, 2005, 32 (11) :3350-3354
[7]   Precise radiochromic film dosimetry using a flat-bed document scanner [J].
Devic, S ;
Seuntjens, J ;
Sham, E ;
Podgorsak, EB ;
Schmidtlein, CR ;
Kirov, AS ;
Soares, CG .
MEDICAL PHYSICS, 2005, 32 (07) :2245-2253
[8]   Clinical use of EBT model Gafchromic™ film in radiotherapy [J].
Fiandra, Christian ;
Ricardi, Umberto ;
Ragona, Riccardo ;
Anglesio, Silvia ;
Giglioli, Francesca Romana ;
Calamia, Elisa ;
Lucio, Francesco .
MEDICAL PHYSICS, 2006, 33 (11) :4314-4319
[9]  
HOPPE RT, 1979, CANCER TREAT REP, V63, P625
[10]  
IAEA, 2000, TECHNICAL REPORT SER, V398