Scanning Electrochemical Microscopy for the Investigation of Galvanic Corrosion of Iron with Zinc in 0.1 M NaCl Solution

被引:23
|
作者
Raj, X. Joseph [1 ]
Nishimura, T. [1 ]
机构
[1] Natl Inst Mat Sci, Res Ctr Strateg Mat, Mat Recycling Design Grp, 1-2-1 Sengen, Tsukuba, Ibaraki 3050047, Japan
关键词
corrosion; galvanic couple; iron; SECM; zinc; DEGRADATION PROCESSES; COATED METALS; COATINGS; SECM; VISUALIZATION; ELECTRODE; STEEL; MODE;
D O I
10.1007/s11665-015-1861-y
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Scanning electrochemical microscopy was used to monitor microscopic aspects of the electrochemical processes at the iron-zinc couple immersed in 0.1 M NaCl aqueous solution. The SECM measured the concentration of chemical species relevant to the corrosion processes. The electrochemical behavior of galvanic Fe/Zn coupling was investigated as a function of time using SECM microelectrode both as Fe/Zn joined together as well as away from each other. SECM amperometric line scan curves were obtained over the Fe/Zn at a constant distance. In the first case, the chemical species participating in the corrosion reactions at the sample are detected at the SECM tip by applying appropriate potential values to the microelectrode. The release of Zn2+ ionic species into the solution phase from local anodic sites, as well as the consumption of dissolved oxygen at the corresponding cathodic locations, was successfully monitored. The results revealed that the galvanic couple where Fe/Zn is close to each other will show higher corrosion rate of zinc than that of galvanic couple away from each other. The Fe/Zn couple away from each other showed a decrease in current values with time. This is due to the formation of oxide layer of Zn over the Fe followed by the protection of the corrosion products with further exposure times.
引用
收藏
页码:474 / 486
页数:13
相关论文
共 50 条
  • [41] Electrochemical corrosion behaviour of zinc and zinc-reduced graphene oxide coatings on mild steel in 3.5% NaCl solution
    R A Dharanendra
    M Shet Prakash
    S Sreenivasa
    S Shivakumara
    Bulletin of Materials Science, 45
  • [42] Electrochemical Investigation of Galvanic Corrosion of Aircraft Materials Couples.
    Mierke, Guenter
    Deutsche Luft- und Raumfahrt, Forschungsbericht, 1976, (76-61):
  • [43] In-situ electrochemical scanning tunneling microscopy studies on the oxidation of iron in alkaline solution
    Khaselev, O
    Sykes, JM
    ELECTROCHIMICA ACTA, 1997, 42 (15) : 2333 - 2337
  • [44] Effect of Conversion Coatings and Oxalate Ion on Corrosion of Pure Zinc in 1 M NaCl Solution
    Yanardag, Turan
    Aksut, A. Abbas
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (01) : 345 - 349
  • [45] Ultrathin protective films of two-dimensional polymers on passivated iron against corrosion in 0.1 M NaCl
    Aramaki, K
    Shimura, T
    CORROSION SCIENCE, 2005, 47 (12) : 2901 - 2914
  • [46] FORMATION AND STUDY OF PITTING CORROSION BY SCANNING ELECTROCHEMICAL MICROSCOPY
    WIPF, DO
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 202 - COLL
  • [47] INITIATION AND STUDY OF LOCALIZED CORROSION BY SCANNING ELECTROCHEMICAL MICROSCOPY
    WIPF, DO
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1994, 93 : 251 - 261
  • [48] Effect of different organic inhibitors on copper corrosion in 0.1 M NaCl
    Rosca, Iulia Mirza
    Llorente, Maria Luisa
    Gonzalez, S.
    Gonzalez, J.E.G.
    UPB Scientific Bulletin, Series B: Chemistry and Materials Science, 60 (01): : 99 - 105
  • [49] Study on Corrosion of Macroporous Silicon in Sodium Hydroxide Solution by Electrochemical Methods and Scanning Electron Microscopy
    Lai, Chuan
    Xiang, Zhen
    Liu, Changlu
    Zhu, Chaoju
    Wang, Hui
    Zhu, Hui
    INTERNATIONAL JOURNAL OF CORROSION, 2015, 2015
  • [50] Corrosion properties of glassy Mg70Al15Ga15 in 0.1 M NaCl solution
    Uhlenhaut, D. I.
    Furrer, A.
    Uggowitzer, P. J.
    Loeffler, J. F.
    INTERMETALLICS, 2009, 17 (10) : 811 - 817