Comparison of digital tomosynthesis and computed tomography for lung nodule detection in SOS screening program

被引:7
作者
Grosso, Maurizio [1 ]
Priotto, Roberto [1 ]
Ghirardo, Donatella [1 ]
Talenti, Alberto [1 ]
Roberto, Emanuele [2 ]
Bertolaccini, Luca [3 ]
Terzi, Alberto [4 ]
Chauvie, Stephane [2 ]
机构
[1] Santa Croce E Carle Hosp, Radiol Dept, Cuneo, Italy
[2] Santa Croce E Carle Hosp, Med Phys Div, Cuneo, Italy
[3] AUSL Romagna Teaching Hosp, Dept Thorac Surg, Ravenna, Italy
[4] Don Calabria Canc Care Ctr, Thorac Surg Div, Negrar, Italy
来源
RADIOLOGIA MEDICA | 2017年 / 122卷 / 08期
关键词
Digital tomosynthesis; Lung cancer; Lung nodule detection; PULMONARY NODULES; CHEST TOMOSYNTHESIS; CANCER; CT; RADIOGRAPHY; GUIDELINES; SCANS;
D O I
10.1007/s11547-017-0765-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To compare the lung nodules' detection of digital tomosynthesis (DTS) and computed tomography (CT) in the context of the SOS (Studio OSservazionale) prospective screening program for lung cancer detection. Materials and methods One hundred and thirty-two of the 1843 subjects enrolled in the SOS study underwent CT because non-calcified nodules with diameters larger than 5 mm and/or multiple nodules were present in DTS. Two expert radiologists reviewed the exams classifying the nodules based on their radiological appearance and their dimension. LUNG-RADS classification was applied to compare receiver operator characteristics curve between CT and DTS with respect to final diagnosis. CT was used as gold standard. Results DTS and CT detected 208 and 179 nodules in the 132 subjects, respectively. Of these 208 nodules, 189 (91%) were solid, partially solid, and ground glass opacity. CT confirmed 140/189 (74%) of these nodules but found 4 nodules that were not detected by DTS. DTS and CT were concordant in 62% of the cases applying the 5-point LUNG-RADS scale. The concordance rose to 86% on a suspicious/non-suspicious binary scale. The areas under the curve in receiver operator characteristics were 0.89 (95% CI 0.83-0.94) and 0.80 (95% CI 0.72-0.89) for CT and DTS, respectively. The mean effective dose was 0.09 +/- 0.04 mSv for DTS and 4.90 +/- 1.20 mSv for CT. Conclusions The use of a common classification for nodule detection in DTS and CT helps in comparing the two technologies. DTS detected and correctly classified 74% of the nodules seen by CT but lost 4 nodules identified by CT. Concordance between DTS and CT rose to 86% of the nodules when considering LUNG-RADS on a binary scale.
引用
收藏
页码:568 / 574
页数:7
相关论文
共 50 条
[21]   Different Lung Nodule Detection Tasks at Different Dose Levels by Different Computed Tomography Image Reconstruction Strategies [J].
Liang, Zhengrong ;
Zhang, Hao ;
Gao, Yongfeng ;
Yang, Jie ;
Ferretti, John ;
Bilfinger, Thomas ;
Yaddanapudi, Kavitha ;
Schweitzer, Mark ;
Bhattacharji, Priya ;
Moore, William .
2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
[22]   Overview of Computer Aided Detection and Computer Aided Diagnosis Systems for Lung Nodule Detection in Computed Tomography [J].
Ziyad, Shabana Rasheed ;
Radha, Venkatachalam ;
Vayyapuri, Thavavel .
CURRENT MEDICAL IMAGING, 2020, 16 (01) :16-26
[23]   QUANTIFICATION OF PULMONARY PATHOLOGY IN CYSTIC FIBROSIS-COMPARISON BETWEEN DIGITAL CHEST TOMOSYNTHESIS AND COMPUTED TOMOGRAPHY [J].
Meltzer, C. ;
Gilljam, M. ;
Vikgren, J. ;
Norrlund, R. R. ;
von Steyern, K. Vult ;
Bath, M. ;
Johnsson, A. A. .
RADIATION PROTECTION DOSIMETRY, 2021, 195 (3-4) :434-442
[24]   Deep-learning-based model observer for a lung nodule detection task in computed tomography [J].
Gong, Hao ;
Hu, Qiyuan ;
Walther, Andrew ;
Koo, Chi Wan ;
Takahashi, Edwin A. ;
Levin, David L. ;
Johnson, Tucker F. ;
Hora, Megan J. ;
Leng, Shuai ;
Fletcher, Joel G. ;
McCollough, Cynthia H. ;
Yu, Lifeng .
JOURNAL OF MEDICAL IMAGING, 2020, 7 (04)
[25]   Lung Nodule Volume Measurement using Digital Chest Tomosynthesis [J].
Hadhazi, D. ;
Czetenyi, B. ;
Horvath, A. ;
Orban, G. ;
Horvath, G. ;
Horvath, A. .
2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, :2026-2031
[26]   Lung ultrasound nodule sign for detection of pulmonary nodule lesions in dogs: Comparison to thoracic radiography using computed tomography as the criterion standard [J].
Pacholec, C. ;
Lisciandro, G. R. ;
Masseau, I ;
Donnelly, L. ;
DeClue, A. ;
Reinero, C. R. .
VETERINARY JOURNAL, 2021, 275
[27]   Lung cancer detection with digital chest tomosynthesis: first round results from the SOS observational study [J].
Bertolaccini, Luca ;
Viti, Andrea ;
Tavella, Chiara ;
Priotto, Roberto ;
Ghirardo, Donatella ;
Grosso, Maurizio ;
Terzi, Alberto .
ANNALS OF TRANSLATIONAL MEDICINE, 2015, 3 (05)
[28]   GPD-Nodule: A Lightweight Lung Nodule Detection and Segmentation Framework on Computed Tomography Images Using Uniform Superpixel Generation [J].
Modak, Sudipta ;
Abdel-Raheem, Esam ;
Rueda, Luis .
IEEE ACCESS, 2024, 12 :154933-154948
[29]   A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference [J].
Ji Yung Choo ;
Ki Yeol Lee ;
Ami Yu ;
Je-Hyeong Kim ;
Seung Heon Lee ;
Jung Won Choi ;
Eun-Young Kang ;
Yu Whan Oh .
European Radiology, 2016, 26 :3147-3154
[30]   Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening Program [J].
Skaane, Per ;
Bandos, Andriy I. ;
Gullien, Randi ;
Eben, Ellen B. ;
Ekseth, Ulrika ;
Haakenaasen, Unni ;
Izadi, Mina ;
Jebsen, Ingvild N. ;
Jahr, Gunnar ;
Krager, Mona ;
Niklason, Loren T. ;
Hofvind, Solveig ;
Gur, David .
RADIOLOGY, 2013, 267 (01) :47-56