High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: Comparison of surface coil and volume coil

被引:20
作者
Bittersohl, Bernd
Huang, Thomas
Schneider, Erika
Biazar, Philip
Winalski, Carl
Lang, Philipp
Yoshioka, Hiroshi
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Cleveland Clin Fdn, Div Radiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[4] Harvard Univ, Sch Med, Dept Orthoped Surg, Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
high-resolution; magnetic resonance imaging (MRI); triangular fibrocartilage complex; surface coil; 3; tesla;
D O I
10.1002/jmri.21077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate high-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T using a surface coil (SC) or volume coil (VC). Materials and Methods: MRI was obtained from nine volunteers in the supine position with a 3-inch SC and in prone position with a transmit-receiver wrist VC at 3T. Coronal two-dimensional-gradient echo (2D-GRE) images (TR/TE/FA = 500 msec/15 msec/40 degrees, 1 mm slice-thickness, 60 mm, field of view [FOV], 192 x 256 matrix) and coronal 3D-GRE images (TR/TE/FA = 33 msec/15 msec/10 degrees, 0.8 mm slice-thickness, 80 mm FOV, 256 X 256 matrix) were used. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the TFCC and surrounding structures were measured. For qualitative measurement, visualization of TFCC and intercarpal ligaments was graded. Results: SNR of TFCC, cartilage, and bone marrow on 2D-GRE with SC/VC was as follows: 5.3/5.3 (TFCC), 16.5/14.4 (cartilage), and 3.61/3.96 (bone marrow). 3D-GRE showed similar SNR. Cartilage-TFCC/cartilage-bone marrow CNR were 11.1/12.8 (SC-2D-GRE), 8.8/10.5 (VC-2D-GRE), 14.1/15.5 (SC-3D-GRE), and 11.9/15.0 (VC-3D-GRE). Quantitative values were not significantly different between SC and VC. Visualization of TFCC and intercarpal ligament with SC was superior to that with VC. All structures show higher scores with 3D-GRE imaging compared to 2D-GRE imaging. Conclusion: SC may provide superior qualitative and quantitative results and can be an alternative in case of difficulty in prone position at 3T.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 50 条
  • [31] Intrinsic ligament and triangular fibrocartilage complex tears of the wrist: comparison of MDCT arthrography, conventional 3-T MRI, and MR arthrography
    Ryan K. L. Lee
    Alex W. H. Ng
    Cina S. L. Tong
    James F. Griffith
    W. L. Tse
    C. Wong
    P. C. Ho
    Skeletal Radiology, 2013, 42 : 1277 - 1285
  • [32] HIGH-RESOLUTION MR-IMAGING OF THE ANAL-SPHINCTER USING AN INTRAVAGINAL SURFACE COIL
    MULLERSCHIMPFLE, M
    FRANZ, H
    LOBINGER, B
    CLAUSSEN, CD
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (06): : 478 - 481
  • [33] High-Resolution 3T MR Angiography of the Carotid Arteries: Comparison of Manual and Semiautomated Quantification of Stenosis
    Habibi, R.
    Lell, M. M.
    Steiner, R.
    Ruehm, S. G.
    Sayre, J. W.
    Nael, K.
    Finn, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (01) : 46 - 52
  • [34] Helmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7 T
    Wright, Alexander C.
    Lemdiasov, Rostislav
    Connick, Thomas J.
    Bhagat, Yusuf A.
    Magland, Jeremy F.
    Song, Hee Kwon
    Toddes, Steven P.
    Ludwig, Reinhold
    Wehrli, Felix W.
    JOURNAL OF MAGNETIC RESONANCE, 2011, 210 (01) : 113 - 122
  • [35] A Novel Flexible Electrotextile 3T MRI RF Coil Array for Carotid Artery Imaging: Design, Characterization, and Prototyping
    Zhang, Daisong
    Rahmat-Samu, Yahya
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2019, 67 (08) : 5115 - 5125
  • [36] High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T
    Di Qian
    Paul A Bottomley
    Journal of Cardiovascular Magnetic Resonance, 14
  • [37] High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T
    Qian, Di
    Bottomley, Paul A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [38] Pushing the limits of high-resolution functional MRI using a simple high-density multi-element coil design
    Petridou, N.
    Italiaander, M.
    van de Bank, B. L.
    Siero, J. C. W.
    Luijten, P. R.
    Klomp, D. W. J.
    NMR IN BIOMEDICINE, 2013, 26 (01) : 65 - 73
  • [39] 3T MRI of Peripheral Vascular Malformations: Characteristics and Comparison of Two Fat-Saturated sequences: Short Tau Inversion Recovery Versus Three-Dimensional High-Resolution Volume Interpolated Gradient Recalled Echo
    Hoehn, Florentine
    Hammer, Simone
    Fellner, Claudia
    Zeman, Florian
    Uller, Wibke
    Brill, Richard
    Guntau, Moritz
    Wildgruber, Moritz
    Wohlgemuth, Walter A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 446 - 458
  • [40] Design and Development of a General-Purpose Transmit/Receive (T/R) Switch for 3T MRI, Compatible for a Linear, Quadrature and Double-Tuned RF Coil
    Thapa, Bijaya
    Kaggie, Joshua
    Sapkota, Nabraj
    Frank, Deborah
    Jeong, Eun-Kee
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2016, 46 (02) : 57 - 65