High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: Comparison of surface coil and volume coil

被引:20
作者
Bittersohl, Bernd
Huang, Thomas
Schneider, Erika
Biazar, Philip
Winalski, Carl
Lang, Philipp
Yoshioka, Hiroshi
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Cleveland Clin Fdn, Div Radiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[4] Harvard Univ, Sch Med, Dept Orthoped Surg, Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
high-resolution; magnetic resonance imaging (MRI); triangular fibrocartilage complex; surface coil; 3; tesla;
D O I
10.1002/jmri.21077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate high-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T using a surface coil (SC) or volume coil (VC). Materials and Methods: MRI was obtained from nine volunteers in the supine position with a 3-inch SC and in prone position with a transmit-receiver wrist VC at 3T. Coronal two-dimensional-gradient echo (2D-GRE) images (TR/TE/FA = 500 msec/15 msec/40 degrees, 1 mm slice-thickness, 60 mm, field of view [FOV], 192 x 256 matrix) and coronal 3D-GRE images (TR/TE/FA = 33 msec/15 msec/10 degrees, 0.8 mm slice-thickness, 80 mm FOV, 256 X 256 matrix) were used. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the TFCC and surrounding structures were measured. For qualitative measurement, visualization of TFCC and intercarpal ligaments was graded. Results: SNR of TFCC, cartilage, and bone marrow on 2D-GRE with SC/VC was as follows: 5.3/5.3 (TFCC), 16.5/14.4 (cartilage), and 3.61/3.96 (bone marrow). 3D-GRE showed similar SNR. Cartilage-TFCC/cartilage-bone marrow CNR were 11.1/12.8 (SC-2D-GRE), 8.8/10.5 (VC-2D-GRE), 14.1/15.5 (SC-3D-GRE), and 11.9/15.0 (VC-3D-GRE). Quantitative values were not significantly different between SC and VC. Visualization of TFCC and intercarpal ligament with SC was superior to that with VC. All structures show higher scores with 3D-GRE imaging compared to 2D-GRE imaging. Conclusion: SC may provide superior qualitative and quantitative results and can be an alternative in case of difficulty in prone position at 3T.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 50 条
  • [21] High-resolution imaging at 3T and 7T with multiring local volume coils
    Fakhereh Mirrashed
    Jonathan C. Sharp
    Iva Cheung
    Boguslaw Tomanek
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 167 - 173
  • [22] High-resolution MRI of basal cell carcinomas of the face using a microscopy coil
    Gufler, Hubert
    Franke, Folker E.
    Rau, Wigbert S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : W480 - W484
  • [23] High-resolution imaging at 3T and 7T with multiring local volume coils
    Mirrashed, F
    Sharp, JC
    Cheung, I
    Tomanek, B
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (04) : 167 - 173
  • [24] High-resolution magnetic resonance imaging of the triangular fibrocartilage complex using compressed sensing sensitivity encoding (SENSE)
    Fujiwara, Hiroki
    Yabuuchi, Hidetake
    Wada, Tatsuhiro
    Kobayashi, Kouji
    Hoshuyama, Toko
    Kamitani, Takeshi
    Ishigami, Kousei
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149
  • [25] Morphologic Characteristics of Atherosclerotic Middle Cerebral Arteries on 3T High-Resolution MRI
    Zhu, X. J.
    Du, B.
    Lou, X.
    Hui, F. K.
    Ma, L.
    Zheng, B. W.
    Jin, M.
    Wang, C. X.
    Jiang, W. -J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (09) : 1717 - 1722
  • [26] Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI
    Ryu, Yeun Chul
    JOURNAL OF MAGNETICS, 2017, 22 (02) : 238 - 243
  • [27] The value of preoperative high-resolution MRI with microscopy coil for facial nonmelanoma skin cancers
    Sheng, Meiying
    Tang, Mengxiao
    Lin, Wei
    Guo, Lingchuan
    He, Wenjun
    Chen, Weixin
    Li, Ke
    Liu, Jianjiang
    Xiao, Can
    Li, Yonggang
    SKIN RESEARCH AND TECHNOLOGY, 2021, 27 (01) : 62 - 69
  • [28] Design and characterization of receive-only surface coil arrays at 3T with integrated solid high permittivity materials
    Ruytenberg, Thomas
    O'Reilly, Thomas P.
    Webb, Andrew G.
    JOURNAL OF MAGNETIC RESONANCE, 2020, 311 (311)
  • [29] Intrinsic ligament and triangular fibrocartilage complex tears of the wrist: comparison of MDCT arthrography, conventional 3-T MRI, and MR arthrography
    Lee, Ryan K. L.
    Ng, Alex W. H.
    Tong, Cina S. L.
    Griffith, James F.
    Tse, W. L.
    Wong, C.
    Ho, P. C.
    SKELETAL RADIOLOGY, 2013, 42 (09) : 1277 - 1285
  • [30] An improved RF and gradient coil system for high resolution in vivo guinea pig cochlea imaging on a 3T clinical magnet
    Kaggie, Joshua D.
    Goodrich, K. Craig
    Kim, Seong-Eun
    Beck, Michael J.
    Parker, Dennis L.
    Merrill, Robb
    Abele, Travis A.
    Wiggins, Richard
    Oakley, Gretchen M.
    Hadley, J. Rock
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2014, 44 (04) : 89 - 101