In vitro and in vivo evaluation of a novel polymer-free everolimus-eluting stent by nitrogen-doped titanium dioxide film deposition

被引:14
作者
Park, Dae Sung [1 ,2 ,5 ]
Bae, In-Ho [1 ,2 ]
Jeon, Myung Ho [1 ,2 ,3 ]
Lim, Kyung Seob [6 ]
Sim, Doo Sun [1 ,3 ]
Hong, Young Joon [3 ]
Lee, So-Youn [1 ,2 ]
Jang, Eun Jae [1 ,2 ]
Shim, Jae-Won [2 ]
Park, Jun-Kyu [4 ]
Lim, Han Chul [3 ]
Kim, Han Byul [3 ]
机构
[1] Chonnam Natl Univ Hosp, Korea Minist Hlth & Welf, Cardiovasc Convergence Res Ctr, Gwangju 61469, South Korea
[2] Korea Cardiovasc Stent Res Inst, Jangsung 57248, South Korea
[3] Chonnam Natl Univ Hosp, Dept Cardiol, Gwangju 61469, South Korea
[4] Sunchon Natl Univ, Dept Polymer Sci & Engn, Suncheon 57922, Peoples R China
[5] Chonnam Natl Univ, Res Inst Med Sci, Gwangju, South Korea
[6] Korea Res Inst Biosci & Biotechnol, Futurist Anim Resource & Res Ctr, Ochang 28116, Chungbuk, South Korea
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2018年 / 91卷
基金
新加坡国家研究基金会;
关键词
Drug-eluting stent; Polymer-free stent; Nitrogen-doped titanium dioxide film; Plasma-enhanced chemical vapor deposition; Everolimus-eluting stent; SURFACE CHARACTERIZATION; PLATELET-ADHESION; CORONARY STENTS; RESTENOSIS; VIVO; METAANALYSIS; ABCIXIMAB;
D O I
10.1016/j.msec.2018.05.064
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Inflammation and thrombosis are linked to the use of polymer-based drug-eluting stents (DES). The aim of this study was to develop a polymer-free everolimus (EVL)-eluting stent using nitrogen-doped titanium dioxide (N-TiO2) and verify its efficacy by in vitro and in vivo assessment in a porcine coronary model. Various analytical approaches such as scanning electron microscopy and atomic force microscopy, electron spectroscopy, Fourier transform infrared spectrometry and contact angle measurement were employed for the characterization. As a part of biocompatibility assessment, platelet adhesion and smooth muscle cell (SMC) proliferation were examined. Bare metal stent (BMS), N-TiO2 stent, everolimus-eluting N-TiO2 (N-TiO2-EVL) stent, and commercialized EVL-eluting stent (EES) were randomly placed in forty coronary arteries in twenty pigs. After four weeks of implantation, the stents were subjected to histological and quantitative analysis. The N-TiO2 film used in this study was well coated without any cracks or peeling. Surface hydrophilicity (88.8% of angle decrement) could be associated with the decrease in surface roughness post N-TiO2 deposition (37.0%). The platelet adhesion on the N-TiO2 surfaces was less than that on the BMS surface. The proliferation of SMC was suppressed in the N-TiO2-EVL group (30.2%) but not in the BMS group. In the animal study, the percent area restenosis was significantly decreased in the N-TiO2-EVL group compared to that in the BMS group. The results (BMS; 47.0 +/- 11.00%, N-TiO2-EVL; 31.7 +/- 10.50%, and EES; 29.1 +/- 11.21%, n = 10, p < 0.05) were almost at par with those of the commercialized EVL-eluting stent. The introduction of N-TiO2 deposition during fabrication of polymer-free DES may be an efficient accessorial process for preventing in-stent restenosis and thrombosis.
引用
收藏
页码:615 / 623
页数:9
相关论文
共 40 条
[1]  
Abizaid Alexandre C, 2007, EuroIntervention, V3, P154
[2]   Clinical performance of drug-eluting stents with biodegradable polymeric coating: a meta-analysis and systematic review [J].
Ahmed, Tarek A. N. ;
Bergheanu, Sandrin C. ;
Stijnen, Theo ;
Plevier, Josepha W. M. ;
Quax, Paul H. A. ;
Jukema, J. Wouter .
EUROINTERVENTION, 2011, 7 (04) :505-516
[3]   Mechanical behavior and in vivo properties of newly designed bare metal stent for enhanced flexibility [J].
Bae, In-Ho ;
Lim, Kyung-Seob ;
Park, Jun-Kyu ;
Park, Dae-Sung ;
Lee, So-Youn ;
Jang, Eun-Jae ;
Ji, Mi Seon ;
Sim, Doo Sun ;
Hong, Young Joon ;
Ahn, Youngkeun ;
Park, Jong Chun ;
Cho, Jeong Gwan ;
Kang, Jung Chaee ;
Kim, In-Su ;
Nah, Jae-Woon ;
Jeong, Myung-Ho .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 21 :1295-1300
[4]   Thromboresistant and endothelialization effects of dopamine-mediated heparin coating on a stent material surface [J].
Bae, In-Ho ;
Park, In-Kyu ;
Park, Dae Sung ;
Lee, Haeshin ;
Jeong, Myung Ho .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (05) :1259-1269
[5]   Free radical functionalization of surfaces to prevent adverse responses to biomedical devices [J].
Bilek, Marcela M. M. ;
Bax, Daniel V. ;
Kondyurin, Alexey ;
Yin, Yongbai ;
Nosworthy, Neil J. ;
Fisher, Keith ;
Waterhouse, Anna ;
Weiss, Anthony S. ;
dos Remedios, Cristobal G. ;
McKenzie, David R. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (35) :14405-14410
[6]   Effectiveness of drug-eluting stents in patients with bare-metal in-stent restenosis -: Meta-analysis of randomized trials [J].
Dibra, Alban ;
Kastrati, Adrian ;
Alfonso, Fernando ;
Seyfarth, Melchior ;
Perez-Vizcayno, Maria-Jose ;
Mehilli, Julinda ;
Schomig, Albert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (05) :616-623
[7]   TIN COATING - SURFACE CHARACTERIZATION AND HEMOCOMPATIBILITY [J].
DION, I ;
ROUAIS, F ;
TRUT, L ;
BAQUEY, C ;
MONTIES, JR ;
HAVLIK, P .
BIOMATERIALS, 1993, 14 (03) :169-176
[8]   Morphological predictors of restenosis after coronary stenting in humans [J].
Farb, A ;
Weber, DK ;
Kolodgie, FD ;
Burke, AP ;
Virmani, R .
CIRCULATION, 2002, 105 (25) :2974-2980
[9]   Differences of Platelet Adhesion and Thrombus Activation on Amorphous Silicon Carbide, Magnesium Alloy, Stainless Steel, and Cobalt Chromium Stent Surfaces [J].
Hansi, Christopher ;
Arab, Amina ;
Rzany, Alexander ;
Ahrens, Ingo ;
Bode, Christoph ;
Hehrlein, Christoph .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (04) :488-496
[10]   Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk [J].
Joner, Michael ;
Finn, Aloke V. ;
Farb, Andrew ;
Mont, Erik K. ;
Kolodgie, Frank D. ;
Ladich, Elena ;
Kutys, Robert ;
Skorija, Kristi ;
Gold, Herman K. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :193-202