A Low-Power and Wide-Range MEMS Capacitive Sensors Interface IC Using Pulse-Width Modulation for Biomedical Applications

被引:16
作者
Arefin, Md Shamsul [1 ]
Redoute, Jean-Michel [1 ]
Yuce, Mehmet Rasit [1 ]
机构
[1] Monash Univ, Dept Elect & Comp Syst Engn, Melbourne, Vic 3800, Australia
关键词
Interface circuit; pulsewidth modulation (PWM); time-based sensing; capacitive sensor; capacitive pressure sensor; TO-VOLTAGE CONVERTER; PRESSURE SENSOR; DESIGN; CHIP; CIRCUIT; OUTPUT; SLOPE;
D O I
10.1109/JSEN.2016.2587668
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a low power, compact, and low-complexity pulse-width modulation-based interface circuit for capacitive MEMS sensors. The circuit is designed using a ring oscillator, an RC controlled pulse generator with high-pass filter, and a self-tuning inverter comparator to produce pulse width, which is proportional to differential capacitance and independent of parasitic capacitance. The high-pass filter is utilized to reduce the bandwidth of noise sources. The circuit provides control over sensitivity, dynamic range, and nominal point for the capacitance measurement by selecting controlling parameters, such as resistance of the RC pulse generator, biasing voltage of the self-tuning inverter comparator, and a reference capacitor using digital control signals. The circuit provides high linearity with higher sensitivity and lower power consumption. The sensitivity of the circuit is 0.56 to 3.62 mu s/pF depending on the controlling parameters. The maximum dynamic sensing range is 22 to 270 pF depending on the controlling parameters. The interface circuit is designed and fabricated using the United Microelectronics Corporation (UMC) 0.18-mu m CMOS technology. It occupies an active area of 0.17 mm(2) and consumes 98 mu W. A capacitive MEMS-based pressure sensor is also connected with the interface circuit to measure pressure throughout the digestive tract. The sensitivity for pressure from 101 to 200 kPa is 60 ns/kPa and from 50 to 101 kPa is 23 ns/kPa.
引用
收藏
页码:6745 / 6754
页数:10
相关论文
共 43 条
[1]   A MEMS Interface IC With Low-Power and Wide-Range Frequency-to-Voltage Converter for Biomedical Applications [J].
Arefin, Md Shamsul ;
Redoute, Jean-Michel ;
Yuce, Mehmet Rasit .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (02) :455-466
[2]  
Arefin MS, 2014, IEEE SENSOR, P1792, DOI 10.1109/ICSENS.2014.6985373
[3]   A microfabricated fringing field capacitive pH sensor with an integrated readout circuit [J].
Arefin, Md Shamsul ;
Coskun, M. Bulut ;
Alan, Tuncay ;
Redoute, Jean-Michel ;
Neild, Adrian ;
Yuce, Mehmet Rasit .
APPLIED PHYSICS LETTERS, 2014, 104 (22)
[4]   Review of the potential of a wireless MEMS and TFT microsystems for the measurement of pressure in the GI tract [J].
Arshak, A ;
Arshak, K ;
Waldron, D ;
Morris, D ;
Korostynska, O ;
Jafer, E ;
Lyons, G .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (05) :347-356
[5]   High-Sensitivity Inductive Pressure Sensor [J].
Bakhoum, Ezzat G. ;
Cheng, Marvin H. M. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (08) :2960-2966
[6]  
Bracke W, 2007, ANALOG CIRC SIG PROC, P1, DOI 10.1007/978-1-4020-6232-2
[7]   Non-lithographically microfabricated capacitive pressure sensor for biomedical applications [J].
Brox, D. ;
Mohammadi, A. R. ;
Takahata, K. .
ELECTRONICS LETTERS, 2011, 47 (18) :1015-U1546
[8]   A current-mode, dual slope, integrated capacitance-to-pulse duration converter [J].
Bruschi, Paolo ;
Nizza, Nicolo ;
Piotto, Massimo .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2007, 42 (09) :1884-1891
[9]   Design of a high-speed differential frequency-to-voltage converter and its application in a 5-GHz frequency-locked loop [J].
Bui, Hung Tien ;
Savaria, Yvon .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2008, 55 (03) :766-774
[10]   Design of Chopper-Stabilized Amplifiers With Reduced Offset for Sensor Applications [J].
Chan, P. K. ;
Cui, J. .
IEEE SENSORS JOURNAL, 2008, 8 (11-12) :1968-1980