Optimization of the determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography-electron capture negative ionization mass spectrometry

被引:119
|
作者
Covaci, A [1 ]
Voorspoels, S [1 ]
机构
[1] Univ Antwerp, Toxicol Ctr, B-2610 Antwerp, Belgium
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 827卷 / 02期
关键词
polybrominated diphenyl ethers; human serum; solid-phase extraction;
D O I
10.1016/j.jchromb.2005.09.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid, sensitive and reproducible method based on solid-phase extraction (SPE) and acidified silica clean-up was developed for the measurement of 12 polybrominated diphenyl ethers (PBDEs), including BDE 209, and 2,2',4,4,5,5'-hexabromobiphenyl (BB 153) in human serum. Several solid-phase sorbents (Empore (TM) C-18, Isolute Pheny], Isolute ENV+ and OASIS (TM) HLB) were tested and it was found that OASIS (TM) HLB (500 mg) gives the highest absolute recoveries (between 64% and 95%, R.S.D. < 17%, n = 3) for all tested analytes and internal standards. Removal of co-extracted biogenic materials was performed using a 6 ml disposable cartridge containing (from bottom to top) silica impregnated with sulphuric acid, activated silica and anhydrous sodium sulphate. PBDEs and BB 153 were quantified using a gas chromatograph coupled with a mass spectrometer (MS) operated in electron-capture negative ionization mode. The method limits of quantification (LOQ) ranged between 0.2 and 25 pg/ml serum (0. 1 and 4 ng/g lipid weight). LOQs were dependent on the analyte levels in procedural blanks which resulted in the highest LOQs for PBDE congeners found in higher concentrations in blanks (e.g. BDE 47, 99 and 209). The use of OASIS (TM) HLB SPE cartridge allowed a good method repeatability (within- and between-day precision < 12% for all congeners, except for BDE 209 < 17%, n = 3). The method was applied to serum samples from a random Belgian population. The obtained results were within the range of PBDE levels in other non-exposed population from Europe. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 50 条
  • [41] Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography-tandem mass spectrometry
    Fontana, Ariel R.
    Lana, Nerina B.
    Martinez, Luis D.
    Altamirano, Jorgelina C.
    TALANTA, 2010, 82 (01) : 359 - 366
  • [42] Determination of tricyclic antidepressants in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry
    Lee, Xiao-Pen
    Hasegawa, Chika
    Kumazawa, Takeshi
    Shinmen, Natsuko
    Shoji, Yukiko
    Seno, Hiroshi
    Sato, Keizo
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (12) : 2265 - 2271
  • [43] Determination of novel brominated flame retardants and polybrominated diphenyl ethers in serum using gas chromatography–mass spectrometry with two simplified sample preparation procedures
    Le Gao
    Jian Li
    Yandan Wu
    Miaohao Yu
    Tian Chen
    Zhixiong Shi
    Xianqing Zhou
    Zhiwei Sun
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7835 - 7844
  • [44] Determination of Azoxystrobin Residues in Fruits and Vegetables by Gas Chromatography/Mass Spectrometry with Solid-Phase Extraction
    Bo Haibo
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (06) : 898 - 901
  • [45] Fast determination of VOCs in workplace air by solid-phase extraction and gas chromatography - Mass spectrometry
    Mangani, F
    Lattanzi, L
    Maione, M
    CHROMATOGRAPHIA, 1998, 47 (1-2) : 57 - 62
  • [46] Determination of Acidic Herbicide in Water by Derivatization Gas Chromatography-Negative Chemical Ionization Mass Spectrometry with Solid Phase Extraction
    Gui Jian-Ye
    Zhang Li
    Liu Ji-Hua
    Zhang Yong-Tao
    Zuo Hai-Ying
    Li Xiao-Ya
    Zhang Lin
    Li Gui-Xiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (08) : 1177 - 1181
  • [47] Liquid Chromatography-Electron Capture Negative Ionization- Tandem Mass Spectrometry Detection of Pesticides in a Commercial Formulation
    Cappiello, Achille
    Termopoli, Veronica
    Palma, Pierangela
    Famiglini, Giorgio
    Saeed, Mansoor
    Perry, Simon
    Navarro, Pablo
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2022, 33 (01) : 141 - 148
  • [48] Multiwalled carbon nanotubes coated fibers for solid-phase microextraction of polybrominated diphenyl ethers in water and milk samples before gas chromatography with electron-capture detection
    Wang, Jun-Xia
    Jiang, Dong-Qing
    Gu, Zhi-Yuan
    Yan, Xiu-Ping
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1137 (01) : 8 - 14
  • [49] Determining Polybrominated Diphenyl Ethers in Surface Waters of Western Pomerania Using Gas Chromatography with Electron Capture Detection
    Byczkiewicz, Marlena
    Jablonski, Maciej
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2015, 24 (03): : 961 - 968
  • [50] Determination of alkylphenol residues in breast and commercial milk by solid-phase extraction and gas chromatography-mass spectrometry
    Lin, Wei-Chun
    Wang, Shu-Li
    Cheng, Chin-Yuan
    Ding, Wang-Hsien
    FOOD CHEMISTRY, 2009, 114 (02) : 753 - 757