Optimization of the determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography-electron capture negative ionization mass spectrometry

被引:119
|
作者
Covaci, A [1 ]
Voorspoels, S [1 ]
机构
[1] Univ Antwerp, Toxicol Ctr, B-2610 Antwerp, Belgium
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 827卷 / 02期
关键词
polybrominated diphenyl ethers; human serum; solid-phase extraction;
D O I
10.1016/j.jchromb.2005.09.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid, sensitive and reproducible method based on solid-phase extraction (SPE) and acidified silica clean-up was developed for the measurement of 12 polybrominated diphenyl ethers (PBDEs), including BDE 209, and 2,2',4,4,5,5'-hexabromobiphenyl (BB 153) in human serum. Several solid-phase sorbents (Empore (TM) C-18, Isolute Pheny], Isolute ENV+ and OASIS (TM) HLB) were tested and it was found that OASIS (TM) HLB (500 mg) gives the highest absolute recoveries (between 64% and 95%, R.S.D. < 17%, n = 3) for all tested analytes and internal standards. Removal of co-extracted biogenic materials was performed using a 6 ml disposable cartridge containing (from bottom to top) silica impregnated with sulphuric acid, activated silica and anhydrous sodium sulphate. PBDEs and BB 153 were quantified using a gas chromatograph coupled with a mass spectrometer (MS) operated in electron-capture negative ionization mode. The method limits of quantification (LOQ) ranged between 0.2 and 25 pg/ml serum (0. 1 and 4 ng/g lipid weight). LOQs were dependent on the analyte levels in procedural blanks which resulted in the highest LOQs for PBDE congeners found in higher concentrations in blanks (e.g. BDE 47, 99 and 209). The use of OASIS (TM) HLB SPE cartridge allowed a good method repeatability (within- and between-day precision < 12% for all congeners, except for BDE 209 < 17%, n = 3). The method was applied to serum samples from a random Belgian population. The obtained results were within the range of PBDE levels in other non-exposed population from Europe. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 50 条
  • [31] Evaluation of gas chromatography-atmospheric pressure chemical ionization tandem mass spectrometry as an alternative to gas chromatography tandem mass spectrometry for the determination of polychlorinated biphenyls and polybrominated diphenyl ethers
    Fang, Jing
    Zhao, Hongzhi
    Zhang, Yanhao
    Wong, Minghung
    He, Yu
    Sun, Qianqian
    Xu, Shunqing
    Cai, Zongwei
    CHEMOSPHERE, 2019, 225 : 288 - 294
  • [32] Optimization of congener-specific analysis of 40 polybrominated diphenyl ethers by gas chromatography/mass spectrometry
    Eljarrat, E
    Lacorte, S
    Barceló, D
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (01): : 76 - 84
  • [33] Micro-solid phase extraction followed by thermal extraction coupled with gas chromatography-mass selective detector for the determination of polybrominated diphenyl ethers in water
    Naing, Nyi Nyi
    Li, Sam Fong Yau
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1458 : 25 - 34
  • [34] Determination of fipronil and its metabolites in edible oil by pollen based solid-phase extraction combined with gas chromatography-electron capture detection
    Zhou, Yi-Lian
    Yue, Shi-Wen
    Cheng, Bing-Wei
    Zhao, Qin
    FOOD CHEMISTRY, 2022, 377
  • [35] Determination of persistent organochlorine pollutants in human serum by combining liquid-liquid extraction and solid-phase extraction with gas chromatography-tandem mass spectrometry
    Qiu, Tian
    Jiang, Weilong
    Bao, Shan
    Qian, Jiankun
    Wang, Chao
    Tang, Song
    Shi, Xiaoming
    Lu, Yifu
    MICROCHEMICAL JOURNAL, 2024, 197
  • [36] Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry
    Hasegawa, Chika
    Kumazawa, Takeshi
    Uchigasaki, Seisaku
    Lee, Xiao-Pen
    Sato, Keizo
    Terada, Masaru
    Kurosaki, Kunihiko
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (07) : 2215 - 2223
  • [37] Determination of novel brominated flame retardants and polybrominated diphenyl ethers in serum using gas chromatography-mass spectrometry with two simplified sample preparation procedures
    Gao, Le
    Li, Jian
    Wu, Yandan
    Yu, Miaohao
    Chen, Tian
    Shi, Zhixiong
    Zhou, Xianqing
    Sun, Zhiwei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (27) : 7835 - 7844
  • [38] Screening and determination of benzodiazepines in whole blood using solid-phase extraction and gas chromatography/mass spectrometry
    Inoue, H
    Maeno, Y
    Iwasa, M
    Matoba, R
    Nagao, M
    FORENSIC SCIENCE INTERNATIONAL, 2000, 113 (1-3) : 367 - 373
  • [39] Simple and fast analysis of tetrabromobisphenol A, hexabromocyclododecane isomers, and polybrominated diphenyl ethers in serum using solid-phase extraction or QuEChERS extraction followed by tandem mass spectrometry coupled to HPLC and GC
    Li, Jian
    Chen, Tian
    Wang, Yuwei
    Shi, Zhixiong
    Zhou, Xianqing
    Sun, Zhiwei
    Wang, Dejun
    Wu, Yongning
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (03) : 709 - 716
  • [40] Solid-phase extraction-electrospray ionization mass spectrometry for the quantification of folate in human plasma or serum
    Nelson, BC
    Pfeiffer, CM
    Margolis, SA
    Nelson, CP
    ANALYTICAL BIOCHEMISTRY, 2004, 325 (01) : 41 - 51