Optimization of the determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography-electron capture negative ionization mass spectrometry

被引:119
|
作者
Covaci, A [1 ]
Voorspoels, S [1 ]
机构
[1] Univ Antwerp, Toxicol Ctr, B-2610 Antwerp, Belgium
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 827卷 / 02期
关键词
polybrominated diphenyl ethers; human serum; solid-phase extraction;
D O I
10.1016/j.jchromb.2005.09.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid, sensitive and reproducible method based on solid-phase extraction (SPE) and acidified silica clean-up was developed for the measurement of 12 polybrominated diphenyl ethers (PBDEs), including BDE 209, and 2,2',4,4,5,5'-hexabromobiphenyl (BB 153) in human serum. Several solid-phase sorbents (Empore (TM) C-18, Isolute Pheny], Isolute ENV+ and OASIS (TM) HLB) were tested and it was found that OASIS (TM) HLB (500 mg) gives the highest absolute recoveries (between 64% and 95%, R.S.D. < 17%, n = 3) for all tested analytes and internal standards. Removal of co-extracted biogenic materials was performed using a 6 ml disposable cartridge containing (from bottom to top) silica impregnated with sulphuric acid, activated silica and anhydrous sodium sulphate. PBDEs and BB 153 were quantified using a gas chromatograph coupled with a mass spectrometer (MS) operated in electron-capture negative ionization mode. The method limits of quantification (LOQ) ranged between 0.2 and 25 pg/ml serum (0. 1 and 4 ng/g lipid weight). LOQs were dependent on the analyte levels in procedural blanks which resulted in the highest LOQs for PBDE congeners found in higher concentrations in blanks (e.g. BDE 47, 99 and 209). The use of OASIS (TM) HLB SPE cartridge allowed a good method repeatability (within- and between-day precision < 12% for all congeners, except for BDE 209 < 17%, n = 3). The method was applied to serum samples from a random Belgian population. The obtained results were within the range of PBDE levels in other non-exposed population from Europe. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 50 条
  • [1] Simultaneous determination of bisphenol A, triclosan, and tetrabromobisphenol A in human serum using solid-phase extraction and gas chromatography-electron capture negative-ionization mass spectrometry
    Alin C. Dirtu
    Laurence Roosens
    Tinne Geens
    Adriana Gheorghe
    Hugo Neels
    Adrian Covaci
    Analytical and Bioanalytical Chemistry, 2008, 391 : 1175 - 1181
  • [2] Simultaneous determination of bisphenol A, triclosan, and tetrabromobisphenol A in human serum using solid-phase extraction and gas chromatography-electron capture negative-ionization mass spectrometry
    Dirtu, Alin C.
    Roosens, Laurence
    Geens, Tinne
    Gheorghe, Adriana
    Neels, Hugo
    Covaci, Adrian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (04) : 1175 - 1181
  • [3] Optimized determination of polybrominated diphenyl ethers and polychlorinated biphenyls in sheep serum by solid-phase extraction-gas chromatography-mass spectrometry
    Zhang, Zulin
    Rhind, Stewart M.
    TALANTA, 2011, 84 (02) : 487 - 493
  • [4] Determination of polybrominated diphenyl ethers in human serum by gas chromatography - inductively coupled plasma mass spectrometry
    Bergant, Matic
    Milacic, Radmila
    Scancar, Janez
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1572 : 112 - 118
  • [5] Determination of polybrominated diphenyl ethers in human blood by gas chromatography-negative chemical ionization-mass spectrometry
    Qu Wei-Yue
    Bi Xin-Hui
    Sheng Guo-Ying
    Lu Shao-You
    Fu Jia-Mo
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 1015 - 1017
  • [6] Human Biomonitoring of Serum Polybrominated Diphenyl Ethers by Supported Liquid Extraction and Gas Chromatography Coupled With Tandem Mass Spectrometry
    Liu, Miao
    Jia, Xiangyu
    Peng, Rongfei
    Bai, Zhijun
    Yuan, Jun
    Tan, Lei
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (21)
  • [7] Simultaneous determination of trace polybrominated diphenyl ethers in serum using gas chromatography-negative chemical ionization mass spectrometry with simplified sample preparation
    Miao, Wenbin
    Wu, Chunhua
    Yang, Jieling
    Lou, Dan
    Jiang, Wei
    Zhou, Zhijun
    ANALYTICAL METHODS, 2015, 7 (14) : 5907 - 5912
  • [8] Simultaneous determination of phthalates and adipates in human serum using gas chromatography-mass spectrometry with solid-phase extraction
    Guo, Zhi-Yong
    Gai, Pan-Pan
    Duan, Jing
    Zhai, Jin-Xia
    Zhao, Sha-Sha
    Wang, Sui
    Wei, Dan-Yi
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (10) : 1094 - 1099
  • [9] Simultaneous determination of polybrominated diphenyl ethers and polychlorinated biphenyls by gas chromatography-tandem mass spectrometry in human serum and plasma
    Lin, Yan-ping
    Pessah, Isaac N.
    Puschner, Birgit
    TALANTA, 2013, 113 : 41 - 48
  • [10] Determination of organochlorine pesticides and polychlorinated biphenyls in human serum using headspace solid-phase microextraction and gas chromatography-electron capture detection
    Lopez, Raul
    Goni, Fernando
    Etxandia, Arsenio
    Millan, Esmeralda
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2): : 298 - 305