Technologies for measuring red blood cell deformability

被引:29
作者
Matthews, Kerryn [1 ,2 ]
Lamoureux, Erik S. [1 ,2 ]
Myrand-Lapierre, Marie-Eve [1 ]
Duffy, Simon P. [2 ,3 ]
Ma, Hongshen [1 ,2 ,4 ,5 ]
机构
[1] Univ British Columbia, Dept Mech Engn, 2054-6250 Appl Sci Lane, Vancouver, BC V6T 1Z4, Canada
[2] Univ British Columbia, Ctr Blood Res, Vancouver, BC, Canada
[3] British Columbia Inst Technol, Vancouver, BC, Canada
[4] Univ British Columbia, Dept Urol Sci, Vancouver, BC, Canada
[5] Vancouver Gen Hosp, Vancouver Prostate Ctr, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院; 瑞典研究理事会;
关键词
DIFFRACTION PHASE MICROSCOPY; ACUTE SPLENIC SEQUESTRATION; ERYTHROCYTE DEFORMABILITY; VISCOELASTIC PROPERTIES; MICROFLUIDIC ANALYSIS; MECHANICAL-PROPERTIES; OPTICAL TWEEZERS; MICROPIPETTE ASPIRATION; THALASSEMIA-INTERMEDIA; TRANSFUSION;
D O I
10.1039/d1lc01058a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Human red blood cells (RBCs) are approximately 8 mu m in diameter, but must repeatedly deform through capillaries as small as 2 mu m in order to deliver oxygen to all parts of the body. The loss of this capability is associated with the pathology of many diseases, and is therefore a potential biomarker for disease status and treatment efficacy. Measuring RBC deformability is a difficult problem because of the minute forces (similar to pN) that must be exerted on these cells, as well as the requirements for throughput and multiplexing. The development of technologies for measuring RBC deformability date back to the 1960s with the development of micropipette aspiration, ektacytometry, and the cell transit analyzer. In the past 10 years, significant progress has been made using microfluidics by leveraging the ability to precisely control fluid flow through microstructures at the size scale of individual RBCs. These technologies have now surpassed traditional methods in terms of sensitivity, throughput, consistency, and ease of use. As a result, these efforts are beginning to move beyond feasibility studies and into applications to enable biomedical discoveries. In this review, we provide an overview of both traditional and microfluidic techniques for measuring RBC deformability. We discuss the capabilities of each technique and compare their sensitivity, throughput, and robustness in measuring bulk and single-cell RBC deformability. Finally, we discuss how these tools could be used to measure changes in RBC deformability in the context of various applications including pathologies caused by malaria and hemoglobinopathies, as well as degradation during storage in blood bags prior to blood transfusions.
引用
收藏
页码:1254 / 1274
页数:21
相关论文
共 215 条
  • [21] Influence of storage on red blood cell rheological properties
    Berezina, TL
    Zaets, SB
    Morgan, C
    Spillert, CR
    Kamiyama, M
    Spolarics, Z
    Deitch, EA
    Machiedo, GW
    [J]. JOURNAL OF SURGICAL RESEARCH, 2002, 102 (01) : 6 - 12
  • [22] Diffraction phase microscopy: principles and applications in materials and life sciences
    Bhaduri, Basanta
    Edwards, Chris
    Hoa Pham
    Zhou, Renjie
    Nguyen, Tan H.
    Goddard, Lynford L.
    Popescu, Gabriel
    [J]. ADVANCES IN OPTICS AND PHOTONICS, 2014, 6 (01): : 57 - 119
  • [23] Bow H, 2011, LAB CHIP, V11, P1065, DOI [10.1039/c0lc00472c, 10.1039/c01c00472c]
  • [24] The transcriptome of the intraerythrocytic developmental cycle of Plasmodium falciparum
    Bozdech, Z
    Llinás, M
    Pulliam, BL
    Wong, ED
    Zhu, JC
    DeRisi, JL
    [J]. PLOS BIOLOGY, 2003, 1 (01) : 85 - 100
  • [25] Optical tweezers for measuring red blood cell elasticity: application to the study of drug response in sickle cell disease
    Brandao, MM
    Fontes, A
    Barjas-Castro, ML
    Barbosa, LC
    Costa, FF
    Cesar, CL
    Saad, STO
    [J]. EUROPEAN JOURNAL OF HAEMATOLOGY, 2003, 70 (04) : 207 - 211
  • [26] Deformation and nano-rheology of red blood cells: An AFM investigation
    Bremmell, Kristen E.
    Evans, Allan
    Prestidge, Clive A.
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2006, 50 (01) : 43 - 48
  • [27] Association of reduced red blood cell deformability and diabetic nephropathy
    Brown, CD
    Ghali, HS
    Zhao, ZH
    Thomas, LL
    Friedman, EA
    [J]. KIDNEY INTERNATIONAL, 2005, 67 (01) : 295 - 300
  • [28] BUCHAN PC, 1980, BRIT J HAEMATOL, V45, P97, DOI 10.1111/j.1365-2141.1980.tb03815.x
  • [29] Bush Michael A, 2010, Am J Manag Care, V16, pS304
  • [30] Transfusion-related acute lung injury (TRALI): a serious adverse event of blood transfusion
    Bux, J