Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety

被引:25
作者
Choi, M. J. [1 ]
Kim, Y. [1 ]
Hong, Y. S. [2 ]
Shim, S. S. [1 ]
Lim, S. M. [1 ]
Lee, J. K. [1 ]
机构
[1] Ewha Womans Univ, Dept Radiol, Sch Med, Seoul 158710, South Korea
[2] Ewha Womans Univ, Dept Internal Med, Sch Med, Seoul 158710, South Korea
关键词
FLUOROSCOPY-GUIDED BIOPSY; SOLITARY PULMONARY NODULES; ASPIRATION BIOPSY; LUNG NODULES; RISK-FACTORS; LESIONS; PNEUMOTHORAX; EXPERIENCE; GUIDANCE;
D O I
10.1259/bjr/95413532
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The purpose of this study was to evaluate the diagnostic accuracy and safety of performing transthoracic needle biopsy (TNB) under combined fluoroscopy and CT guidance using a C-arm cone-beam CT (CBCT) system. Methods: We evaluated the diagnostic accuracy and safety of performing TNB using a C-arm CBCT system. We retrospectively evaluated 99 TNB cases performed in 98 patients using a C-arm CBCT system with an 18-gauge automated cutting needle. We reviewed the diagnostic accuracy according to the size and depth of the lesion, incidence of complications, additional treatment for complications, procedure time, number of needle passes per biopsy and radiation dose. Results: The final diagnoses revealed 72 malignant and 27 benign lesions. The overall malignancy sensitivity, malignancy specificity and diagnostic accuracy were 95.8%, 100% and 97.0%, respectively, and those for small pulmonary nodules <20mm in size were 94.1%, 100% and 96.6%, respectively. There was no significant difference in the correct diagnosis of malignancy according to lesion size (p=0.634) or depth (p=0.542). For benign lesions, a specific diagnosis was obtained in 14 cases (51.9%). TNB induced complications in 19 out of 99 procedures (19.2%), including pneumothorax (16.2%), immediate haemoptysis (2.0%) and subcutaneous emphysema (1.0%). Among these, four patients with pneumothorax required chest tube insertion (2.0%) or pig-tail catheter drainage (2.0%). The mean procedure time, number of needle passes and radiation doses were 11.9+/-4.0 min, 1.2+/-0.5 times and 170.0+/-67.2 mGy, respectively. Conclusion: TNB using a C-arm CBCT system provides high diagnostic accuracy with a low complication rate and a short procedure time, particularly for small pulmonary nodules.
引用
收藏
页码:E182 / E187
页数:6
相关论文
共 21 条
[1]   CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: A prospective randomized controlled clinical trial [J].
Carlson, SK ;
Felmlee, JP ;
Bender, CE ;
Ehman, RL ;
Classic, KL ;
Hoskin, TL ;
Harmsen, WS ;
Hu, HH .
RADIOLOGY, 2005, 237 (02) :701-708
[2]   Benefits and safety of CT fluoroscopy in interventional radiologic procedures [J].
Carlson, SK ;
Bender, CE ;
Classic, KL ;
Zink, FE ;
Quam, JP ;
Ward, EM ;
Oberg, AL .
RADIOLOGY, 2001, 219 (02) :515-520
[3]   Guidance of percutaneous pulmonary biopsies with real-time CT fluoroscopy [J].
Froelich, JJ ;
Ishaque, N ;
Regn, J ;
Saar, B ;
Walthers, EM ;
Klose, KJ .
EUROPEAN JOURNAL OF RADIOLOGY, 2002, 42 (01) :74-79
[4]   CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate [J].
Geraghty, PR ;
Kee, ST ;
McFarlane, G ;
Razavi, MK ;
Sze, DY ;
Dake, MD .
RADIOLOGY, 2003, 229 (02) :475-481
[5]   Flat-Panel Volume CT: Fundamental Principles, Technology, and Applications [J].
Gupta, Rajiv ;
Cheung, Arnold C. ;
Bartling, Soenke H. ;
Lisauskas, Jennifer ;
Grasruck, Michael ;
Leidecker, Christianne ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Brady, Thomas J. .
RADIOGRAPHICS, 2008, 28 (07) :2009-2022
[6]   CT GUIDED BIOPSY [J].
HAAGA, JR ;
REICH, NE ;
HAVRILLA, TR ;
ALFIDI, RJ ;
MEANEY, TF .
CLEVELAND CLINIC QUARTERLY, 1977, 44 (01) :27-33
[7]   Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses [J].
Heck, SL ;
Blom, P ;
Berstad, A .
EUROPEAN RADIOLOGY, 2006, 16 (06) :1387-1392
[8]   CT Fluoroscopy-Guided Biopsy of 1,000 Pulmonary Lesions Performed With 20-Gauge Coaxial Cutting Needles: Diagnostic Yield and Risk Factors for Diagnostic Failure [J].
Hiraki, Takao ;
Mimura, Hidefumi ;
Gobara, Hideo ;
Iguchi, Toshihiro ;
Fujiwara, Hiroyasu ;
Sakurai, Jun ;
Matsui, Yusuke ;
Inoue, Daisaku ;
Toyooka, Shinichi ;
Sano, Yoshifumi ;
Kanazawa, Susumu .
CHEST, 2009, 136 (06) :1612-1617
[9]   Biopsy of lung nodules with use of I-I device under intermittent CT fluoroscopic guidance: Preliminary clinical study [J].
Irie, T ;
Kajitani, M ;
Matsueda, K ;
Arai, Y ;
Inaba, Y ;
Kujiraoka, Y ;
Itai, Y .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (02) :215-219
[10]   Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems [J].
Jin, Kwang Nam ;
Park, Chang Min ;
Goo, Jin Mo ;
Lee, Hyun Ju ;
Lee, Youkyung ;
Kim, Jung Im ;
Choi, So Young ;
Kim, Hyo-Cheol .
EUROPEAN RADIOLOGY, 2010, 20 (09) :2108-2115