Prospective contralateral eye study to compare conventional and wavefront-guided laser in situ keratomileusis

被引:10
|
作者
D'Arcy, Fiona [1 ]
Kirwan, Caitriona [1 ]
Qasem, Qasim [1 ]
O'Keefe, Michael [1 ,2 ]
机构
[1] Mater Private Hosp, Dublin 7, Ireland
[2] Univ Coll Dublin, Dublin 4, Ireland
关键词
customized; LASIK; myopia;
D O I
10.1111/j.1755-3768.2009.01845.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare outcomes of customized/wavefront guided with conventional ablation in myopic patients with or without astigmatism undergoing laser in situ keratomileusis. Methods: A prospective, comparative, contralateral eye study was performed. Sixty-eight eyes of 34 myopic patients with similar refractive error in both eyes were included. One eye was randomly selected to undergo conventional and the fellow eye customized ablation. Surgery was performed using the Technolas 217z laser (Bausch & Lomb, Surrey, UK). Uncorrected visual acuity, manifest refractive spherical equivalent (MRSE), astigmatism, aberrometry and contrast sensitivity were recorded pre and 3 months postoperatively. Results: Mean MRSE treated in the conventional and customized groups were 3.77 +/- 1.61 dioptres and -3.83 +/- 1.59 dioptres respectively. Three months postoperatively there was no significant difference between the groups in mean MRSE (p = 0.99) or cylinder (p = 0.56). The factor increase in postoperative total higher order aberrations (HOAs) was less in the customized (1.32) compared with the conventional (1.54) treatment group but did not reach statistical significance (p = 0.08). Scotopic contrast sensitivity decreased significantly postoperatively in the conventional but not in the customized treatment group. Conclusion: Visual acuity and refractive error outcomes were similar in both treatment group and no patient preference was observed. Customized ablation was associated with a smaller but not statistically significant postoperative increase in HOAs, better preservation of scotopic contrast sensitivity, quicker treatment time and removal of less corneal tissue.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [1] Quality of vision after wavefront-guided laser in situ keratomileusis or photorefractive keratectomy: Contralateral eye evaluation
    Lee, Michele D.
    Manche, Edward E.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (01) : 54 - 59
  • [2] Visual outcomes after wavefront-guided photorefractive keratectomy and wavefront-guided laser in situ keratomileusis: Prospective comparison
    Moshirfar, Majid
    Schliesser, Joshua A.
    Chang, Joann C.
    Oberg, Thomas J.
    Mifflin, Mark D.
    Townley, Richard
    Livingston, Myrna K.
    Kurz, Christopher J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) : 1336 - 1343
  • [3] Outcomes of wavefront-guided laser in situ keratomileusis for hyperopia
    Keir, Nancy J.
    Simpson, Trefford
    Hutchings, Natalie
    Jones, Lyndon
    Fonn, Desmond
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) : 886 - 893
  • [4] Wavefront-Guided Versus Wavefront-Optimized Laser in situ Keratomileusis for Patients With Myopia: A Prospective Randomized Contra lateral Eye Study
    He, Lingmin
    Liu, Anthony
    Manche, Edward E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (06) : 1170 - 1178
  • [5] Corneal wavefront-guided customized laser in situ keratomileusis after penetrating keratoplasty
    Imamoglu, Serhat
    Kaya, Vedat
    Oral, Deniz
    Perente, Irfan
    Basarir, Berna
    Yilmaz, Omer Faruk
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (05) : 785 - 792
  • [6] Comparison of optical quality parameters and ocular aberrations after wavefront-guided laser in-situ keratomileusis versus wavefront-guided laser epithelial keratomileusis for myopia
    Lee, Kwanghyun
    Ahn, Ji Min
    Kim, Eung Kweon
    Kim, Tae-im
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (09) : 2163 - 2169
  • [7] One-year eye-to-eye comparison of wavefront-guided versus wavefront-optimized laser in situ keratomileusis in hyperopes
    Sales, Christopher S.
    Manche, Edward E.
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 2229 - 2238
  • [8] Objective and subjective preoperative refraction techniques for wavefront-optimized and wavefront-guided laser in situ keratomileusis
    Perez-Straziota, Claudia E.
    Randleman, J. Bradley
    Stulting, R. Doyle
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) : 256 - 259
  • [9] Astigmatic outcomes in myopic wavefront-guided laser in situ keratomileusis versus wavefront-guided photorefractive keratectomy using vector analysis
    Lee, Michele D.
    Toy, Brian C.
    Manche, Edward E.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (11) : 1350 - 1354
  • [10] Visual acuity and higher-order aberrations with wavefront-guided and wavefront-optimized laser in situ keratomileusis
    Perez-Straziota, Claudia E.
    Randleman, J. Bradley
    Stulting, R. Doyle
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03) : 437 - 441