A Novel Method for γ-photons Depth-of-Interaction Detection in Monolithic Scintillation Crystals

被引:18
作者
Pani, Roberto [1 ]
Bettiol, Marco [2 ]
Preziosi, Enrico [2 ,3 ]
Borrazzo, Cristian [2 ]
Pellegrini, Rosanna [2 ]
Gonzalez, Antonio J. [4 ]
Conde, Pablo [4 ]
Cinti, Maria Nerina [2 ]
Fabbri, Andrea [2 ]
Di Castro, Elisabetta [5 ]
Majewski, Stan [6 ]
机构
[1] Sapienza Univ Rome, Dept Med Surg Sci & Biotechnol, I-00185 Rome, Italy
[2] Sapienza Univ Rome, Dept Mol Med, I-00161 Rome, Italy
[3] Sapienza Univ Rome, SAIMLAL Dept, Doctorate Sch Biol & Mol Med, Morphofunct Sci Biophys, I-00161 Rome, Italy
[4] CSIC, I3M, Valencia 46022, Spain
[5] Sapienza Univ Rome, Dept Radiol Sci Oncol & Pathol, I-00185 Rome, Italy
[6] Univ Virginia, Charlottesville, VA 22903 USA
关键词
Brain imaging; depth-of-interaction; monolithic scintillation crystal; PET; PET/MRI scanner; POSITION-RESOLUTION; PET SCANNER; DOI;
D O I
10.1109/TNS.2016.2539287
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Achieved spatial resolution of the PET systems is often limited by the parallax error due to the lack of information about the Depth of Interaction (DoI) inside the crystal of the incoming 511 keV annihilation photons. The smaller the diameter of the PET ring and the thicker the scintillator are, the more this error affects imaging performance. In this work, a DoI calculator suitable for monolithic scintillation crystals and based on the shape of the scintillation light distribution at the photodetector surface has been proposed. To test the estimator performance, a test PET module with a 50 x 50 x 20 mm monolithic LYSO crystal coupled to a 12 x 12 SiPM array has been employed. In addition, for calibration and validation of the method, Geant4 simulations have been also used. The key result of the application of the proposed DoI estimator is obtaining a continuous DoI estimation with an average DoI resolution of about 5 mm in the 20 mm-thick crystal. Benefiting from the DoI estimation capabilities of the method, it has been also possible to achieve additional important goals, first of all reducing the parallax error. First, because the scintillation light collection varies as a function of the 3D position of the interaction of the annihilation photon inside the crystal, a method to correct this response variation via a proper 3D look-up-table is proposed. This has led to an improvement of about 35% in energy resolution. Moreover, a DoI-dependent position algorithm has been proposed, allowing an improvement of both planar (X-Y) position linearity and planar spatial resolution. This algorithm is specifically developed for the rows/columns multi-channel readout logic, that reduces the number of independent channels from N x N to N + N, where N is the number of SiPM photodetection elements (12 in our case) in each row and column. This development was performed in the framework of the MindView PET/MRI brain imaging project.
引用
收藏
页码:2487 / 2495
页数:9
相关论文
共 21 条
  • [1] Maximum-Likelihood Methods for Processing Signals From Gamma-Ray Detectors
    Barrett, Harrison H.
    Hunter, William C. J.
    Miller, Brian William
    Moore, Stephen K.
    Chen, Yichun
    Furenlid, Lars R.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 725 - 735
  • [2] A depth of interaction detector for PET with GSO crystals doped with different amounts of Ce
    Inadama, N
    Murayama, H
    Omura, T
    Yamashita, T
    Yamamoto, S
    Ishibashi, H
    Kawai, H
    Omi, K
    Umehara, T
    Kasahara, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 629 - 633
  • [3] Positron emission tomography (PET) detectors with depth-of- interaction (DOI) capability
    Ito M.
    Hong S.J.
    Lee J.S.
    [J]. Biomedical Engineering Letters, 2011, 1 (2) : 70 - 81
  • [4] A Four-Layer DOI Detector With a Relative Offset for Use in an Animal PET System
    Ito, Mikiko
    Lee, Jae Sung
    Kwon, Sun Il
    Lee, Geon Song
    Hong, Byungsik
    Lee, Kyong Sei
    Sim, Kwang-Souk
    Lee, Seok Jae
    Rhee, June Tak
    Hong, Seong Jong
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 976 - 981
  • [5] Optimization of LSO LuYAP phoswich detector for small animal PET
    Jung, Jin Ho
    Choi, Yong
    Chung, Yong Hyun
    Devroede, Olivier
    Krieguer, Magalie
    Bruyndonckx, Peter
    Tavernier, Stefaan
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (03) : 669 - 675
  • [6] Multi-scale algorithm for improved scintillation detection in a CCD-based gamma camera
    Korevaar, Marc A. N.
    Heemskerk, Jan W. T.
    Goorden, Marlies C.
    Beekman, Freek J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (04) : 831 - 842
  • [7] Dependency of energy-, position- and depth of interaction resolution on scintillation crystal coating and geometry
    Lerche, Christoph W.
    Ros, Ana
    Herrero, Vicente
    Esteve, Raul
    Monzo, Jose M.
    Sebastia, Angel
    Sanchez, Filomeno
    Munar, Antoni
    Benlloch, Jose M.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1344 - 1351
  • [8] DOI measurement with monolithic scintillation crystals:: a primary performance evaluation
    Lerche, Christoph W.
    Ros, Ana
    Gadea, Rafael
    Colom, Ricardo J.
    Toledo, Francisco J.
    Herrero, Vicente
    Monzo, Jose M.
    Sebastia, Angel
    Abellan, Dori
    Sanchez, Filomeno
    Correcher, Carlos
    Gonzalez, Antonio J.
    Munar, Antoni
    Benlloch, Jose M.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2594 - +
  • [9] Levin A, 1997, IEEE NUCL SCI CONF R, P702
  • [10] Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction
    Maas, Marnix C.
    Schaart, Dennis R.
    van der Laan, D. J.
    Bruyndonckx, Peter
    Lemaitre, Cedric
    Beekman, Freek J.
    van Eijk, Carel W. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) : 1893 - 1908