A label-free electrochemical immunosensor for direct, signal-on and sensitive pesticide detection

被引:41
作者
Tran, H. V. [1 ]
Yougnia, R. [1 ]
Reisberg, S. [1 ]
Piro, B. [1 ]
Serradji, N. [1 ]
Nguyen, T. D. [2 ]
Tran, L. D. [3 ]
Dong, C. Z. [1 ]
Pham, M. C. [1 ]
机构
[1] Univ Paris Diderot, ITODYS, UMR CNRS 7086, F-75205 Paris 13, France
[2] Vietnamese Acad Sci & Technol, ITT, Hanoi, Vietnam
[3] Vientamese Acad Sci & Technol, IMS, Hanoi, Vietnam
关键词
Conjugated polymer; Electrochemical immunosensor; Square wave voltammetry; Label-free detection; Cross-reactivity; Atrazine; Pesticide; IMPEDIMETRIC IMMUNOSENSOR; TRIAZINE HERBICIDES; ENVIRONMENTAL WATERS; OPTICAL IMMUNOSENSOR; ATRAZINE DETECTION; DNA SENSOR; BIOSENSORS; RESIDUES; FILMS; TRANSDUCTION;
D O I
10.1016/j.bios.2011.09.035
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new electropolymerizable monomer, [N-(6-(4-hydroxy-6-isopropylamino-1,3,5-triazin-2-ylamino)hexyl) 5-hydroxy-1,4-naphthoquinone-3-propionamide], has been designed for use in a label-free electrochemical immunosensor when polymerized on an electrode and coupled with a monoclonal anti-atrazine antibody. This monomer contains three functional groups: hydroxyl group for electropolymerization, quinone group for its transduction capability, and hydroxyatrazine as bioreceptor element. Square wave voltammetry shows that the polymer film, poly[N-(6-(4-hydroxy-6-isopropylamino-1,3,5-triazin-2-ylamino)hexyl) 5-hydroxy-1,4-naphthoquinone-3-propionamide], presents negative current change following anti-atrazine antibody complexation and positive current change after atrazine addition in solution. This constitutes a direct, label-free and signal-on electrochemical immunosensor, with a very low detection limit of ca. 1 pM, i.e. 0.2 ng L-1, one of the lowest reported for such immunosensors. This is far lower than the detection limit required by the European Union directives for drinkable water and food samples (0.1 mu g L-1). The strategy described has great promise for the development of simple, cost-effective and reagentless on-site environmental monitors. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 38 条
[1]   THE CONCEPTS OF CROSSREACTIVITY AND SPECIFICITY IN IMMUNOLOGY [J].
BERZOFSKY, JA ;
SCHECHTER, AN .
MOLECULAR IMMUNOLOGY, 1981, 18 (08) :751-763
[2]   A BIOSENSOR AS WARNING DEVICE FOR THE DETECTION OF CYANIDE, CHLOROPHENOLS, ATRAZINE AND CARBAMATE PESTICIDES [J].
BESOMBES, JL ;
COSNIER, S ;
LABBE, P ;
REVERDY, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :255-263
[3]   REAL-TIME ANALYSIS OF COMPETITIVE-BINDING USING GRATING COUPLER IMMUNOSENSORS FOR PESTICIDE DETECTION [J].
BIER, FF ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (02) :125-130
[4]   A DIRECT OPTICAL IMMUNOSENSOR FOR ATRAZINE DETECTION [J].
BRECHT, A ;
PIEHLER, J ;
LANG, G ;
GAUGLITZ, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :289-299
[5]   Gas chromatography/ion trap mass spectrometry applied for the anal sis of triazine herbicides in environmental waters by an isotope dilution technique [J].
Cai, ZW ;
Wang, DL ;
Ma, WT .
ANALYTICA CHIMICA ACTA, 2004, 503 (02) :263-270
[6]   The isolation of super-sensitive anti-hapten antibodies from combinatorial antibody libraries derived from sheep [J].
Charlton, K ;
Harris, WJ ;
Porter, AJ .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :639-646
[7]   Surface plasmon resonance sensor for pesticide detection [J].
Chegel, VI ;
Shirshov, YM ;
Piletskaya, EV ;
Piletsky, SA .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 48 (1-3) :456-460
[8]   Biosensors based on electropolymerized films: new trends [J].
Cosnier, S .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) :507-520
[9]   Poly(amphiphilic pyrrole)-tyrosinase-peroxidase electrode for amplified flow injection-amperometric detection of phenol [J].
Cosnier, S ;
Popescu, IC .
ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) :145-151
[10]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456