High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell

被引:2
|
作者
Chen Jia-jin [1 ,2 ]
Wang Gui-shi [1 ]
Liu Kun [1 ]
Tan Tu [1 ]
Cheng Gang [1 ]
Tian Xing [1 ]
Gao Xiao-ming [1 ,2 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
关键词
Tunable laser; Direct absorption spectroscopy; Optical multi-pass absorption cell; Carbon dioxide; Detection; DIODE-LASER; CO2; SPECTROSCOPY;
D O I
10.3964/j.issn.1000-0593(2019)01-0292-05
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Carbon dioxide is one of the most important greenhouse gases playing an important role in climate change and human activities, so the detection of carbon dioxide concentration has an important significance. Highly sensitive detection of carbon dioxide gas was achieved by using near infrared tunable diode laser absorption spectroscopy combined with self-designed portable miniaturized cylindrical mirror multi-pass absorption cell. The cylindrical mirrors multi-pass absorption cell was optimized and designed by using a light transmission matrix programmed with Matlab software, compared with traditional Herriott multipass cell, which has the advantages of high mirror utilization and longer optical path length in the same volume. An effective optical path length of 14 m was achieved with 15 cm physical length. In present work, a DFB diode laser emission at 1. 57 mu m was used as a light source. Direct absorption spectroscopy method was used to detect the CO2, and the Allan variance was used to analyze the system performance. The results showed that the detection sensitivity of the system can be achieved 5. 3 mu L.L-1 with the average time of 5 s, and a detection sensitivity of 33. 1 mu L.L-1 can be achieved by averaging in 235 s. In addition, CO2 in the atmosphere was measured by the developed CO2 sensor, the measured results showed that the concentration of CO2 in the atmosphere is about 383. 4 mu L.L-1 The tunable diode laser absorption spectroscopy (IDLAS) system based on cylindrical mirrors multi-pass absorption cell, combined with the cylindrical mirrors multi pass cell can achieve long optical path in a small volume and tunable diode laser absorption spectroscopy technology has the advantages of high sensitivity, high resolution and fast response, greatly reduces volume and improves detection sensitivity of the system, which has a broad application in the field of gas detection.
引用
收藏
页码:292 / 296
页数:5
相关论文
共 16 条
  • [1] SPECTRUM LINE PROFILES - VOIGT FUNCTION
    ARMSTRONG, BH
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1967, 7 (01): : 61 - +
  • [2] Simultaneous Measurements of CO2 and CO Using a Single Distributed-Feedback (DFB) Diode Laser Near 1.57 μm at Elevated Temperatures
    Cai, Tingdong
    Gao, Guangzhen
    Chen, Weidong
    Liu, Gang
    Gao, Xiaoming
    [J]. APPLIED SPECTROSCOPY, 2011, 65 (01) : 108 - 112
  • [3] Activation of TLR2 and TLR6 by Dengue NS1 Protein and Its Implications in the Immunopathogenesis of Dengue Virus Infection
    Chen, Jincheng
    Ng, Mary Mah-Lee
    Chu, Justin Jang Hann
    [J]. PLOS PATHOGENS, 2015, 11 (07)
  • [4] H2S trace concentration measurements using off-axis integrated cavity output spectroscopy in the near-infrared
    Chen, W.
    Kosterev, A. A.
    Tittel, F. K.
    Gao, X.
    Zhao, W.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (02): : 311 - 315
  • [5] Laser spectroscopic monitoring of gas emission and measurements of the 13C/12C isotope ratio in CO2 from a wood-based combustion
    Cousin, Julien
    Chen, Weidong
    Fourmentin, Marc
    Fertein, Eric
    Boucher, Daniel
    Cazier, Fabrice
    Nouali, Habiba
    Dewaele, Dorothee
    Douay, Marc
    Rothman, Laurence S.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2008, 109 (01): : 151 - 167
  • [6] OFF-AXIS PATHS IN SPHERICAL MIRROR INTERFEROMETERS
    HERRIOTT, D
    KOMPFNER, R
    KOGELNIK, H
    [J]. APPLIED OPTICS, 1964, 3 (04): : 523 - &
  • [7] Multipass optical cell based upon two cylindrical mirrors for tunable diode laser absorption spectroscopy
    Kasyutich, V. L.
    Martin, P. A.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 88 (01): : 125 - 130
  • [8] A Review of Signal Enhancement and Noise Reduction Techniques for Tunable Diode Laser Absorption Spectroscopy
    Li, Jingsong
    Yu, Benli
    Zhao, Weixiong
    Chen, Weidong
    [J]. APPLIED SPECTROSCOPY REVIEWS, 2014, 49 (08) : 666 - 691
  • [9] Laser-spectrometric gas analysis: CO2-TDLAS at 2 μm
    Nwaboh, Javis A.
    Werhahn, Olav
    Ortwein, Pascal
    Schiel, Detlef
    Ebert, Volker
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (01)
  • [10] The HITRAN2012 molecular spectroscopic database
    Rothman, L. S.
    Gordon, I. E.
    Babikov, Y.
    Barbe, A.
    Benner, D. Chris
    Bernath, P. F.
    Birk, M.
    Bizzocchi, L.
    Boudon, V.
    Brown, L. R.
    Campargue, A.
    Chance, K.
    Cohen, E. A.
    Coudert, L. H.
    Devi, V. M.
    Drouin, B. J.
    Fayt, A.
    Flaud, J. -M.
    Gamache, R. R.
    Harrison, J. J.
    Hartmann, J. -M.
    Hill, C.
    Hodges, J. T.
    Jacquemart, D.
    Jolly, A.
    Lamouroux, J.
    Le Roy, R. J.
    Li, G.
    Long, D. A.
    Lyulin, O. M.
    Mackie, C. J.
    Massie, S. T.
    Mikhailenko, S.
    Mueller, H. S. P.
    Naumenko, O. V.
    Nikitin, A. V.
    Orphal, J.
    Perevalov, V.
    Perrin, A.
    Polovtseva, E. R.
    Richard, C.
    Smith, M. A. H.
    Starikova, E.
    Sung, K.
    Tashkun, S.
    Tennyson, J.
    Toon, G. C.
    Tyuterev, Vl. G.
    Wagner, G.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 130 : 4 - 50