Small fetal abdominal circumference in the second trimester and subsequent low maternal plasma glucose after a glucose challenge test is associated with the delivery of a small-for-gestational age neonate

被引:16
|
作者
Bienstock, J. L. [1 ]
Holcroft, C. J. [1 ]
Althaus, J. [1 ]
机构
[1] Johns Hopkins Med Inst, Dept Obstet & Gynecol, Div Maternal Fetal Med, Baltimore, MD 21205 USA
关键词
low glucose screen; small abdominal circumference; small for gestational age;
D O I
10.1002/uog.5316
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To evaluate the predictive value of a combination of the 1 h 50-g glucose challenge test (GCT) and second-trimester ultrasound measurement of fetal abdominal circumference (AC) in identifying patients who will go on to deliver small-for-gestational age (SGA) neonates. The individual predictive power Of these tests has been indicated by previous studies, but this study examines the combined use of these indicators in predicting SGA. Methods This retrospective cohort study included 576 consecutive patients with singleton gestations examined over a 3-year period. Patients' electronic medical records were abstracted to obtain the result of the GCT, the fetal AC measured by ultrasound examination between 18 and 22 weeks' gestation, and the birth weight. SGA and small AC were defined as birth weight or AC < 10(th) percentile for gestational age, according to published nomograms. A low GCT was defined as < 100 mg/dL. P < 0.05 was considered significant. Results The prevalence of SGA in the study population was 8.7% (50/576). The frequency of SGA neonates was significantly higher in patients with a low GCT (27/207) in the second trimester than in those with a normal GCT (231369) (13% vs. 6.2%, P = 0.005). Similarly, the frequency of SGA neonates was higher among patients with fetal A C < 10(th) percentile than among those with a normal fetal AC on second-trimester ultrasound examination (17% vs. 8%, P = 0.08), although this difference did not reach statistical significance. Of interest, among patients with both a small feral A C and a low GCT the incidence of SGA neonates was 32% (6/19), but there were no SGA neonates among those with a small A C and normal GCT (0/17) (P = 0.014). Among patients with a small fetal AC the sensitivity of using low GCT to predict subsequent delivery of a SGA neonate was 100%, with a specificity of 57%, positive predictive value 32% and negative predictive value 100%. Conclusions Small AC on routine second-trimester anomaly sonogram should trigger a closer evaluation of maternal GCT. If the GCT is also low, more intensive surveillance for the possible development of a SGA infant is warranted. Copyright (C) 2008 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:517 / 519
页数:3
相关论文
共 17 条
  • [1] Fetal abdominal circumference in the second trimester and prediction of small for gestational age at birth
    Doulaveris, Georgios
    Gallagher, Patience
    Romney, Elizabeth
    Richley, Michael
    Gebb, Juliana
    Rosner, Mara
    Dar, Pe'er
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2020, 33 (14) : 2415 - 2421
  • [2] Fetal growth restriction with abnormal individual biometric parameters at second trimester ultrasound is associated with small for gestational age neonate at delivery
    DeBolt, Chelsea A.
    Sarker, Minhazur
    Cohen, Natalie
    Kaplowitz, Elianna
    Buckley, Ayisha
    Stone, Joanne
    Bianco, Angela
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2022, 272 : 1 - 5
  • [3] Low maternal PAPP-A is associated with small-for-gestational age newborns and stillbirths
    Marttala, Jaana
    Peuhkurinen, Sini
    Laitinen, Paivi
    Gissler, Mika
    Nieminen, Pentti
    Ryynanen, Markku
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2010, 89 (09) : 1226 - 1228
  • [4] First-trimester prediction of small-for-gestational age neonates incorporating fetal Doppler parameters and maternal characteristics
    Seravalli, Viola
    Block-Abraham, Dana M.
    Turan, Ozhan M.
    Doyle, Lauren E.
    Kopelman, Jerome N.
    Atlas, Robert O.
    Jenkins, Chuka B.
    Blitzer, Miriam G.
    Baschat, Ahmet A.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 211 (03) : 261.e1 - 261.e8
  • [5] Low maternal awareness of fetal movement is associated with small for gestational age infants
    Saastad, Eli
    Ahlborg, Tone
    Froen, J. Frederik
    JOURNAL OF MIDWIFERY & WOMENS HEALTH, 2008, 53 (04) : 345 - 352
  • [6] Second- to third-trimester longitudinal growth assessment for prediction of small-for-gestational age and late fetal growth restriction
    Caradeux, J.
    Eixarch, E.
    Mazarico, E.
    Basuki, T. R.
    Gratacos, E.
    Figueras, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2018, 51 (02) : 219 - 224
  • [7] Relation between low 50-g glucose challenge test results and small-for-gestational-age infants
    Shinohara, Satoshi
    Hirai, Mitsuo
    Hirata, Shuji
    Suzuki, Kohta
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2015, 41 (11) : 1752 - 1756
  • [8] Use of the 50-g glucose challenge test to predict small-for-gestational-age neonates
    Tanacan, Atakan
    Eyupoglu, Mert
    Fadiloglu, Erdem
    Zengin, Hatice Yagmur
    Karaagaoglu, Ergun
    Beksac, Mehmet Sinan
    JOURNAL OF DIABETES, 2020, 12 (11) : 791 - 797
  • [9] Third trimester ultrasound estimated fetal weight for increasing prenatal prediction of small-for-gestational age newborns in low-risk pregnant women
    Martin-Palumbo, Giovanna
    Atanasova, Vangeliya Blagoeva
    Rego Tejeda, Maria Teresa
    Antolin Alvarado, Eugenia
    Bartha, Jose Luis
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (25) : 6721 - 6726
  • [10] Maternal PlGF and sFlt-1 are Associated with Low Birth Weight and/or Small-for-Gestational Age Neonates in Pregnancy with or without Preeclampsia
    Luo, Wenbo
    Tang, Pingping
    Lv, Yan
    Song, Yijun
    Hu, Huiying
    Gao, Jinsong
    Liu, Juntao
    AJP REPORTS, 2025, 15 (01): : e36 - e42