Bayesian optimization to design a novel x-ray shaping device

被引:5
作者
Whelan, Brendan [1 ,2 ]
Trovati, Stefania [2 ,3 ]
Wang, Jinghui [2 ,5 ]
Fahrig, Rebecca [6 ,7 ]
Maxim, Peter G. [8 ]
Hanuka, Adi [4 ]
Shumail, Muhammad [4 ]
Tantawi, Sami [4 ,9 ]
Merrick, Julian [4 ]
Perl, Joseph [4 ]
Keall, Paul [1 ]
Loo, Billy W., Jr. [2 ,9 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Sch Hlth Sci, ACRF Image X Inst, Sydney, NSW 2015, Australia
[2] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[3] Lawrence Berkeley Natl Lab, Berkeley, CA USA
[4] SLAC Natl Accelerator Lab, Menlo Pk, CA USA
[5] Varian Med Syst, Palo Alto, CA USA
[6] Siemens Healthineers, Innovat Adv Therapies, Forchheim, Germany
[7] Friedrich Alexander Univ, Dept Comp Sci 5, Erlangen, Germany
[8] Univ Calif Irvine, Dept Radiat Oncol, Irvine, CA USA
[9] Stanford Univ, Sch Med, Stanford Canc Inst, Stanford, CA 94305 USA
基金
澳大利亚国家健康与医学研究理事会;
关键词
collimation; Monte Carlo; optimization; RADIOTHERAPY; PERFORMANCE; MLC;
D O I
10.1002/mp.15887
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC)-a complex mechatronic device comprising over one hundred individually powered tungsten 'leaves' that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed "SPHINX": Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray "beamlets." Methods A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm(2) were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. Results The optimized 5-, 7-, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm(2) and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 +/- 1.9 mm to 0.01 +/- 0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm(2) field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Conclusions Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.
引用
收藏
页码:7623 / 7637
页数:15
相关论文
共 23 条
  • [1] Reducing treatment machine downtime with a preventative MLC maintenance procedure
    Agnew, Christina Elizabeth
    Esteve, Sergio
    Whitten, Glenn
    Little, William
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 85 : 1 - 7
  • [2] A proposal for a Geant4 physics list for radiotherapy optimized in physics performance and CPU time
    Arce, Pedro
    Ignacio Lagares, Juan
    Diego Azcona, Juan
    Aguilar-Redondo, Pedro-Borja
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 964
  • [3] Arnfield M R, 2001, Med Dosim, V26, P179, DOI 10.1016/S0958-3947(01)00058-9
  • [4] Estimating the demand for radiotherapy from the evidence: A review of changes from 2003 to 2012
    Barton, Michael B.
    Jacob, Susannah
    Shafiq, Jesmin
    Wong, Karen
    Thompson, Stephen R.
    Hanna, Timothy P.
    Delaney, Geoff P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 140 - 144
  • [5] Monte Carlo modeling and simulations of the High Definition (HD120) micro MLC and validation against measurements for a 6 MV beam
    Borges, C.
    Zarza-Moreno, M.
    Heath, E.
    Teixeira, N.
    Vaz, P.
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 415 - 423
  • [6] A 3D printed superconducting aluminium microwave cavity
    Creedon, Daniel L.
    Goryachev, Maxim
    Kostylev, Nikita
    Sercombe, Timothy B.
    Tobar, Michael E.
    [J]. APPLIED PHYSICS LETTERS, 2016, 109 (03)
  • [7] Physics and biology of ultrahigh dose-rate (FLASH) radiotherapy: a topical review
    Esplen, Nolan
    Mendonca, Marc S.
    Bazalova-Carter, Magdalena
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [8] Performance of the NIRS fast scanning system for heavy-ion radiotherapy
    Furukawa, Takuji
    Inaniwa, Taku
    Sato, Shinji
    Shirai, Toshiyuki
    Takei, Yuka
    Takeshita, Eri
    Mizushima, Kota
    Iwata, Yoshiyuki
    Himukai, Takeshi
    Mori, Shinichiro
    Fukuda, Shigekazu
    Minohara, Shinichi
    Takada, Eiichi
    Murakami, Takeshi
    Noda, Koji
    [J]. MEDICAL PHYSICS, 2010, 37 (11) : 5672 - 5682
  • [9] Gamzina D., 2019, COPPER RECONSIDERED, P1, DOI [10.1109/IVEC.2019.8744750, DOI 10.1109/IVEC.2019.8744750]
  • [10] Understanding High-Dose, Ultra-High Dose Rate, and Spatially Fractionated Radiation Therapy
    Griffin, Robert J.
    Ahmed, Mansoor M.
    Amendola, Beatriz
    Belyakov, Oleg
    Bentzen, Soren M.
    Butterworth, Karl T.
    Chang, Sha
    Coleman, C. Norman
    Djonov, Valentin
    Formenti, Sylvia C.
    Glatstein, Eli
    Guha, Chandan
    Kalnicki, Shalom
    Le, Quynh-Thu
    Loo, Billy W., Jr.
    Mahadevan, Anand
    Massaccesi, Mariangela
    Maxim, Peter G.
    Mohiuddin, Majid
    Mohiuddin, Mohammed
    Mayr, Nina A.
    Obcemea, Ceferino
    Petersson, Kristoffer
    Regine, William
    Roach, Mack
    Romanelli, Pantaleo
    Simone, Charles B., II
    Snider, James W.
    Spitz, Douglas R.
    Vikram, Bhadrasain
    Vozenin, Marie-Catherine
    Abdel-Wahab, May
    Welsh, James
    Wu, Xiaodong
    Limoli, Charles L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 107 (04): : 766 - 778