3D-T2W-TSE radiotherapy treatment planning MRI using compressed sensing acceleration for prostate cancer: Image quality and delineation value

被引:7
作者
Wong, Oi Lei [1 ]
Poon, Darren M. C. [2 ]
Kam, Miachael K. M. [2 ]
Lo, Gladys G. [3 ]
Fung, Winky W. K. [4 ]
Man, Shei Yee [4 ]
Xue, Cindy [1 ]
Yu, Siu Ki [5 ]
Cheung, Kin Yin [5 ]
Yuan, Jing [1 ]
机构
[1] Hong Kong Sanat & Hosp, Res Dept, 8-F Li Shi Fan Block,2 Village Rd, Hong Kong, Peoples R China
[2] Hong Kong Sanat & Hosp, Comprehens Oncol Ctr, Hong Kong, Peoples R China
[3] Hong Kong Sanat & Hosp, Dept Diagnost & Intervent Radiol, Hong Kong, Peoples R China
[4] Hong Kong Sanat & Hosp, Dept Radiotherapy, Hong Kong, Peoples R China
[5] Hong Kong Sanat & Hosp, Med Phys Dept, Hong Kong, Peoples R China
关键词
compressed sensing (CS); planning MRI; prostate cancer; radiotherapy treatment planning; SPIN-ECHO SEQUENCE; RADIATION-THERAPY; CT; BRACHYTHERAPY; ACQUISITION; ANATOMY; TUMOR;
D O I
10.1111/ajco.13752
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To assess the image quality and delineation value of compressed sensing (CS)-accelerated 3D T2W turbo-spin-echo (TSE) sequence for radiotherapy treatment planning (RTP) of prostate cancer. Methods An optimized CS-accelerated 3D-T2W-TSE was determined by volunteer imaging and applied for clinical RTP-MRI. This optimized CS-accelerated planning MRI and the standardized adaptive MRI acquired at 1.5T were retrospectively analyzed in 26 prostate cancer patients who were to receive MR-guided radiotherapy. Signal-to-noise ratio (SNR) and relative contrast ratio (CR) were quantitatively assessed. Image quality and artifacts were qualitatively assessed using a five-point scale rating. Delineation value in the prostate and organs-at-risk (OARs) was also rated and compared. Wilcoxon signed-rank test was used for SNR, relative CR, and rating comparisons. The interobserver rating agreement was evaluated by percent agreement. Results Significantly better SNR and relative CR in the prostate, rectum, bowel, penis, and penile bulb, while significantly worse in the cauda equina, were observed on the planning MRI. Significantly better ratings of image quality and artifacts were given to the planning MRI, with much less Gibbs ringing and reconstruction artifacts. Significantly better delineation value rating was achieved on the planning MRI in the prostate, seminal vesicle, rectum, penis, penile bulb, and testes, while significantly worse in the cauda equina. A strong to almost perfect interobserver rating agreement was obtained. Conclusion This study suggested that CS acceleration is applicable and valuable in prostate RTP-MRI. CS-accelerated 3D-T2W-TSE images should benefit the delineation of prostate and many OARs.
引用
收藏
页码:E369 / E377
页数:9
相关论文
共 39 条
[1]  
Böckelmann F, 2019, STRAHLENTHER ONKOL, V195, P153, DOI 10.1007/s00066-018-1377-0
[2]   Accelerated MRI of the Lumbar Spine Using Compressed Sensing: Quality and Efficiency [J].
Bratke, Grischa ;
Rau, Robert ;
Weiss, Kilian ;
Kabbasch, Christoph ;
Sircar, Krishnan ;
Morelli, John N. ;
Persigehl, Thorsten ;
Maintz, David ;
Giese, Daniel ;
Haneder, Stefan .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (07) :E164-E175
[3]   Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo [J].
Busse, Reed F. ;
Brau, Anja C. S. ;
Vu, Anthony ;
Michelich, Charles R. ;
Bayram, Ersin ;
Kijowski, Richard ;
Reeder, Scott B. ;
Rowley, Howard A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :640-649
[4]   Analysis of intraprostatic failures in patients treated with hormonal therapy and radiotherapy: Implications for conformal therapy planning [J].
Cellini, N ;
Morganti, AG ;
Mattiucci, GC ;
Valentini, V ;
Leone, M ;
Luzi, S ;
Manfredi, R ;
Dinapoli, N ;
Digesu', C ;
Smaniotto, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (03) :595-599
[5]   The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer [J].
Debois, M ;
Oyen, R ;
Maes, F ;
Verswijvel, G ;
Gatti, G ;
Bosmans, H ;
Feron, M ;
Bellon, E ;
Kutcher, G ;
Van Poppel, H ;
Vanuytsel, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04) :857-865
[6]   Compressed sensing MRI of different organs: ready for clinical daily practice? [J].
Delattre, Benedicte Marie Anne ;
Boudabbous, Sana ;
Hansen, Catrina ;
Neroladaki, Angeliki ;
Hachulla, Anne-Lise ;
Vargas, Maria Isabel .
EUROPEAN RADIOLOGY, 2020, 30 (01) :308-319
[7]   Magnetic resonance imaging for prostate cancer radiotherapy [J].
Dinh, Cuong V. ;
Steenbergen, Peter ;
Ghobadi, Ghazaleh ;
Heijmink, Stijn W. T. J. P. ;
Pos, Floris J. ;
Haustermans, Karin ;
van der Heide, Uulke A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (03) :446-451
[8]   A brief review of parallel magnetic resonance imaging [J].
Heidemann, RM ;
Özsarlak, Ö ;
Parizel, PM ;
Michiels, J ;
Kiefer, B ;
Jellus, V ;
Müller, M ;
Breuer, F ;
Blaimer, M ;
Griswold, MA ;
Jakob, PM .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2323-2337
[9]   Vessel-sparing radiation and functional anatomy-based preservation for erectile function after prostate radiotherapy [J].
Lee, Jae Y. ;
Spratt, Daniel E. ;
Liss, Adam L. ;
McLaughlin, Patrick W. .
LANCET ONCOLOGY, 2016, 17 (05) :E198-E208
[10]   Accelerating knee MR imaging: Compressed sensing in isotropic three-dimensional fast spin-echo sequence [J].
Lee, Seung Hyun ;
Lee, Young Han ;
Suh, Jin-Suck .
MAGNETIC RESONANCE IMAGING, 2018, 46 :90-97