BR38, a New Ultrasound Blood Pool Agent

被引:44
作者
Schneider, Michel [1 ]
Anantharam, Brijesh [2 ]
Arditi, Marcel [1 ]
Bokor, Daniela [3 ]
Broillet, Anne [1 ]
Bussat, Philippe [1 ]
Fouillet, Xavier [1 ]
Frinking, Peter [1 ]
Tardy, Isabelle [1 ]
Terrettaz, Jacques [1 ]
Senior, Roxy [2 ,4 ]
Tranquart, Francois [1 ]
机构
[1] Bracco Suisse SA, CH-1228 Geneva, Switzerland
[2] Northwick Pk Hosp & Clin Res Ctr, Dept Clin Cardiol, Harrow HA1 3UJ, Middx, England
[3] Bracco Imaging SpA, Milan, Italy
[4] Royal Brompton Hosp, Dept Clin Cardiol, London SW3 6LY, England
关键词
BR38; ultrasound contrast agent; safety; myocardial perfusion imaging; liver imaging; phase I; CONTRAST-ENHANCED ULTRASOUND; INTRAVENOUS-INJECTION; CANCER;
D O I
10.1097/RLI.0b013e318217b821
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate BR38, a new microbubble-based blood pool agent for contrast-enhanced ultrasound imaging. Materials and Methods: The size characteristics of BR38 microbubbles were measured by Coulter counting. The backscatter and attenuation coefficients were determined as a function of frequency. Additional measurements included the surface charge, osmolality, viscosity, and resistance to hydrostatic pressure. Extensive pharmacological and toxicological studies were conducted on the final formulation in rats and dogs. The blood levels and elimination of the gaseous component C 4 F 10 were determined in the rabbit. Contrast-enhanced echographic examinations were performed in pigs focusing on the myocardium and the liver. Finally, safety testing and preliminary imaging experiments were performed in a Phase I clinical study in human volunteers. Results: BR38 suspensions are isotonic, nonviscous, and show a high resistance to hydrostatic pressure. Their backscatter coefficient is high at >= 2 MHz and attenuation shows a maximum at 4 MHz, slowly decreasing at higher frequencies. The no adverse effect levels of 1 mu L/kg (rats) and 5 mu L/kg (dogs) expressed as microbubble gas volume, observed in repeated toxicology studies, correspond to 50 and 250 times the expected imaging dose in human beings (0.02 mu L/kg), respectively. No effects on cardiovascular and respiratory parameters were observed in rats and dogs. C 4 F 10 is eliminated within minutes from blood and excreted in expired air. Imaging experiments showed strong and persistent enhancement of the myocardium and the liver. A late phase was observed in the liver, in animals and in human volunteers. No serious adverse events and no significant changes in vital signs, electrocardiographs, and laboratory tests were observed in Phase I human volunteers. Conclusions: BR38 shows a very good safety profile. It is characterized by a long persistence and low shadowing. BR38 is a promising ultrasound blood pool agent for noncardiac and cardiac applications including myocardial perfusion imaging.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 31 条
[1]   Guidelines for the use of contrast agents in ultrasound [J].
Albrecht, T ;
Blomley, M ;
Bolondi, L ;
Claudon, M ;
Correas, JM ;
Cosgrove, D ;
Greiner, L ;
Jäger, K ;
de Jong, N ;
Leen, E ;
Lencioni, R ;
Lindsell, D ;
Martegani, A ;
Solbiati, L ;
Thorelius, L ;
Tranquart, F ;
Weskott, HP ;
Whittingham, T .
ULTRASCHALL IN DER MEDIZIN, 2004, 25 (04) :249-256
[2]  
*AM PHARM ASS, 1986, HDB PHARM EXC, P209
[3]   scVEGF Microbubble Ultrasound Contrast Agents A Novel Probe for Ultrasound Molecular Imaging of Tumor Angiogenesis [J].
Anderson, Christopher R. ;
Rychak, Joshua J. ;
Backer, Marina ;
Backer, Joseph ;
Ley, Klaus ;
Klibanov, Alexander L. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (10) :579-585
[4]  
BZYL J, 2011, EUROPEAN J RADI 0512
[5]   Ultrasonic characterization of ultrasound contrast agents [J].
de Jong, Nico ;
Emmer, Marcia ;
van Wamel, Annemieke ;
Versluis, Michel .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (08) :861-873
[6]   Contrast enhanced ultrasound imaging [J].
Feinstein, Steven B. ;
Coll, Blai ;
Staub, Daniel ;
Adam, Dan ;
Schinkel, Arend F. L. ;
ten Cate, Folkert J. ;
Thomenius, Kai .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (01) :106-115
[7]   Vascular Endothelial Growth Factor Receptor 2-Specific Microbubbles for Molecular Ultrasound Detection of Prostate Cancer in a Rat Model [J].
Fischer, Thomas ;
Thomas, Anke ;
Tardy, Isabell ;
Schneider, Michel ;
Huenigen, Hana ;
Custodis, Pia ;
Beyersdorff, Dirk ;
Plendl, Johanna ;
Schnorr, Joerg ;
Diekmann, Felix ;
Gemeinhardt, Ole .
INVESTIGATIVE RADIOLOGY, 2010, 45 (10) :675-684
[8]   Influence of microbubble surface charge on capillary transit and myocardial contrast enhancement [J].
Fisher, NG ;
Christiansen, JP ;
Klibanov, A ;
Taylor, RP ;
Kaul, S ;
Lindner, JR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (04) :811-819
[9]   Influence of bubble size distribution on the echogenicity of ultrasound contrast agents -: A study of SonoVue™ [J].
Gorce, JM ;
Arditi, M ;
Schneider, M .
INVESTIGATIVE RADIOLOGY, 2000, 35 (11) :661-671
[10]   Myocardial imaging with a new transpulmonary lipid-fluorocarbon echo contrast agent: Experimental studies in pigs [J].
Grauer, SE ;
Pantely, GA ;
Xu, JP ;
Ge, SP ;
Giraud, GD ;
Shiota, T ;
Sahn, DJ .
AMERICAN HEART JOURNAL, 1996, 132 (05) :938-945