Novel peptidylated surfaces for interference-free electrochemical detection of cardiac troponin I

被引:53
作者
Dhawan, Sameer [1 ]
Sadanandan, Sandhya [1 ]
Haridas, V. [1 ]
Voelcker, Nicolas H. [2 ,3 ]
Prieto-Simon, Beatriz [3 ]
机构
[1] Indian Inst Technol Delhi, Dept Chem, New Delhi 110016, India
[2] Monash Univ, Monash Inst Pharmaceut Sci, Parkville, Vic 3052, Australia
[3] Univ South Australia, Future Ind Inst, Adelaide, SA 5095, Australia
基金
澳大利亚研究理事会;
关键词
Peptides; Self-assembly; Electrochemical immunosensor; Cardiac troponin I; Interference free; LABEL-FREE; CARDIOVASCULAR-DISEASE; PROTEIN ADSORPTION; BIOMARKERS; IMMUNOSENSOR; NANOPARTICLES; BIOSENSORS; ELECTRODE; STORAGE;
D O I
10.1016/j.bios.2017.08.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Novel peptidylated surfaces were designed to minimise interferences when electrochemically detecting cardiac troponin I in complex biological samples. Disulfide-cored peptide dendrons featuring carbomethoxy groups were self-assembled on gold electrodes. The carbomethoxy groups were deprotected to obtain carboxylic groups used to immobilise antibodies for cardiac troponin I marker. The chemisorption of two types of peptides, one containing triazole and the other with native peptide bonds, on a gold substrate was studied by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and X-ray photoelectron spectroscopy (XPS). Peptides formed ordered self-assembled monolayers, contributing to a more efficient display of the subsequently immobilised antibodies towards their binding to the antigen. As a result, electrochemical immunosensors prepared by self-assembly of peptides afforded higher sensitivities for cardiac troponin I than those prepared by the chemisorption of alkane thiolated compounds. Triazolic peptide-modified immunosensors showed extraordinary sensitivity towards cardiac troponin I [1.7 mu A/(ng/mL) in phosphate buffer], but suffered from surface fouling in 10% serum. Modification with non-triazolic peptides gave rise to anti-fouling properties and still enabled the detection of cardiac troponin I at pg/mL concentrations in 10% serum without significant matrix effects.
引用
收藏
页码:486 / 492
页数:7
相关论文
共 29 条
[1]  
Ahammad AJS, 2011, INT J ELECTROCHEM SC, V6, P1906
[2]   Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor [J].
Akter, Rashida ;
Jeong, Bongjin ;
Lee, Yong-Mi ;
Choi, Jong-Soon ;
Rahman, Md. Aminur .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :637-643
[3]   Candidate-based proteomics in the search for biomarkers of cardiovascular disease [J].
Anderson, L .
JOURNAL OF PHYSIOLOGY-LONDON, 2005, 563 (01) :23-60
[4]   Approaches Toward Allowing Electroanalytical Devices to be Used in Biological Fluids [J].
Barfidokht, Abbas ;
Gooding, J. Justin .
ELECTROANALYSIS, 2014, 26 (06) :1182-1196
[5]   The effect of freezing and long-term storage on the stability of cardiac troponin T [J].
Basit, Majid ;
Bakshi, Nasir ;
Hashem, Mustafa ;
Allebban, Zuhair ;
Lawson, Noel ;
Rosman, Howard S. ;
Maciejko, James J. .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 128 (01) :164-167
[6]   Hemocompatible Mixed-Charge Copolymer Brushes of Pseudozwitterionic Surfaces Resistant to Nonspecific Plasma Protein Fouling [J].
Chang, Yung ;
Shu, Shih-Hung ;
Shih, Yu-Ju ;
Chu, Chih-Wei ;
Ruaan, Ruoh-Chyu ;
Chen, Wen-Yih .
LANGMUIR, 2010, 26 (05) :3522-3530
[7]   Cardiac point of care testing: A focused review of current National Academy of Clinical Biochemistry guidelines and measurement platforms [J].
Christenson, Robert H. ;
Azzazy, Hassan M. E. .
CLINICAL BIOCHEMISTRY, 2009, 42 (03) :150-157
[8]  
Damodaran Vinod B, 2016, Biomater Res, V20, P18
[9]   The impact of dendrimer-grafted modifications to model silicon surfaces on protein adsorption and bacterial adhesion [J].
Eichler, Mirjam ;
Katzur, Verena ;
Scheideler, Lutz ;
Haupt, Michael ;
Geis-Gerstorfer, Juergen ;
Schmalz, Gottfried ;
Ruhl, Stefan ;
Mueller, Rainer ;
Rupp, Frank .
BIOMATERIALS, 2011, 32 (35) :9168-9179
[10]   Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers [J].
Fathil, M. F. M. ;
Arshad, M. K. Md ;
Gopinath, Subash C. B. ;
Hashim, U. ;
Adzhri, R. ;
Ayub, R. M. ;
Ruslinda, A. R. ;
Nuzaihan, M. M. N. ;
Azman, A. H. ;
Zaki, M. ;
Tang, Thean-Hock .
BIOSENSORS & BIOELECTRONICS, 2015, 70 :209-220