Evolution of a novel technology for gastroesophageal reflux disease: a safety perspective of magnetic sphincter augmentation

被引:15
作者
DeMarchi, Janet [1 ]
Schwiers, Michael [2 ]
Soberman, Mark [3 ]
Tokarski, Allison [4 ]
机构
[1] Ethicon Inc, Med Affairs, Cincinnati, OH 45242 USA
[2] Ethicon Inc, Biostat, Cincinnati, OH USA
[3] Ethicon Inc, Med Safety, Cincinnati, OH USA
[4] Ethicon Inc, Clin Affairs, Cincinnati, OH USA
关键词
gastroesophageal reflux disease; GERD; LINX; magnetic sphincter augmentation; MSA; MANAGEMENT-SYSTEM; LINX(R) REFLUX; ESOPHAGEAL; EFFICACY;
D O I
10.1093/dote/doab036
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Magnetic sphincter augmentation using the LINX (R) device is a minimally invasive surgical option for patients with gastroesophageal reflux disease. An estimated 30,000 devices have been implanted worldwide. Device removals and erosion are identified risks. The objective of this analysis is to explore the procedure evolution with an emphasis on the removals and associated characteristics that may guide future clinical practice. TheManufacturer and User FacilityDevice Experience and Ethicon's complaint databases were queried for all surgical device explants since January 2013. Device unit sales were used to determine the rates. The endpoint was based upon the time from implant to explant. Explant and erosion rates were calculated at yearly intervals and the Kaplan-Meier estimator was used to measure the time to explant. Chi-square analyses were used to investigate the risk of explant associated with the size, geography and implant year. Overall, 7-year cumulative risk of removal was 4.81% (95% Confidence Interval (CI) CI: 4.31-5.36%). The likelihood of removal was significantly related to the device size (P < 0.0001), with smaller sizes being more likely to be explanted. The primary reasons for device removal and relative percentages were dysphagia/odynophagia (47.9%), persistent gastroesophageal reflux disease (20.5%) and unknown/other (11.2%). Overall, the 7-year cumulative risk of erosion was 0.28% (95% CI: 0.17-0.46%). The average device size increased from 14.2 beads +/- 1.0 in 2013 to 15.3 beads +/- 1.2 in 2019 (P < 0.001). Surgical technique and perioperative management play an important role in the outcomes. Clinical practice changes since magnetic sphincter augmentation has been incorporated into clinical use are associated with improved outcomes and should be further characterized. Smaller device size is associated with increased removal and erosion rates.
引用
收藏
页数:7
相关论文
共 24 条
  • [21] The effect of esophageal and gastric distension on the crural diaphragm
    Shafik, A
    Shafik, I
    El Sibai, O
    Mostafa, RM
    [J]. WORLD JOURNAL OF SURGERY, 2006, 30 (02) : 199 - 204
  • [22] Lower Esophageal Sphincter Augmentation for Gastroesophageal Reflux Disease: The Safety of a Modern Implant
    Smith, C. Daniel
    Ganz, Robert A.
    Lipham, John C.
    Bell, Reginald C.
    Rattner, David W.
    [J]. JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2017, 27 (06): : 586 - 591
  • [23] Removing the magnetic sphincter augmentation device: operative management and outcomes
    Tatum, James M.
    Alicuben, Evan
    Bildzukewicz, Nikolai
    Samakar, Kamran
    Houghton, Caitlin C.
    Lipham, John C.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (08): : 2663 - 2669
  • [24] Torax/Ethicon, 2010, G060172 IDE TOR ETH