Prediction of peak shape as a function of retention in reversed-phase liquid chromatography

被引:28
|
作者
Baeza-Baeza, JJ [1 ]
García-Alvarez-Coque, MC [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Spain
关键词
non-gaussian peak model; parabolic variance; peak shape; efficiency; diuretics;
D O I
10.1016/j.chroma.2003.09.059
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optimisation of the resolution of multicomponent samples in HPLC is usually carried out by changing the elution conditions and considering the variation in retention of the analytes, to which a standard peak shape is assigned. However, the change in peak shape with the composition of the mobile phase can ruin the optimisation process, yielding unexpected overlaps in the experimental chromatograms for the predicted optimum, especially for complex mixtures. The possibility of modelling peak shape, in addition to peak position, is therefore attractive. A simple modified-Gaussian model with a parabolic variance, which is a function of conventional experimental parameters: retention time (t(R)), peak height (H-0), standard deviation at the peak maximum (sigma(0)), and left (A) and right (B) halfwidths, is proposed. The model is a simplification of a previous equation proposed in our laboratory. Linear and parabolic relationships were found between the peak shape parameters (go, A and B) and t(R), with a mean relative error of 1-5% in most cases. This error was partially due to variations in peak position and shape among injections, which in some cases were above 2%. Correlations between (sigma(0), A and B) and the retention time, which is easily modelled as a function of mobile phase composition, allowed a simple and reliable prediction of chromatographic peaks. A parameter that depends on the slopes of the linear relationships for A and B versus tR is also proposed to evaluate column efficiency. The modified-Gaussian model was used to describe the peaks of six diuretics of diverse acid-base behaviour and polarity, which were eluted with 15 mobile phases where the composition was varied between 30 and 50% (v/v) acetonitrile and the pH between 3 and 7. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [1] INTERACTION INDEXES FOR PREDICTION OF RETENTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    JANDERA, P
    COLIN, H
    GUIOCHON, G
    ANALYTICAL CHEMISTRY, 1982, 54 (03) : 435 - 441
  • [2] RETENTION PREDICTION OF SMALL PEPTIDES IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    JINNO, K
    TANIGAWA, E
    CHROMATOGRAPHIA, 1988, 25 (07) : 613 - 617
  • [3] Deep learning for retention time prediction in reversed-phase liquid chromatography
    Fedorova, Elizaveta S.
    Matyushin, Dmitriy D.
    Plyushchenko, Ivan, V
    Stavrianidi, Andrey N.
    Buryak, Aleksey K.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1664
  • [4] RETENTION PREDICTION FOR POLYMER ADDITIVES IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    JINNO, K
    YOKOYAMA, Y
    JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2): : 325 - 334
  • [5] Simulating retention in reversed-phase liquid chromatography
    Siepmann, J. Ilja
    Rafferty, Jake L.
    Sun, Li
    Schure, Mark R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233
  • [6] EFFECTS OF AMINE MODIFIERS ON RETENTION AND PEAK SHAPE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KIEL, JS
    MORGAN, SL
    ABRAMSON, RK
    JOURNAL OF CHROMATOGRAPHY, 1985, 320 (02): : 313 - 323
  • [7] Influence of stationary phase solvation on shape selectivity and retention in reversed-phase liquid chromatography
    Limsavarn, L
    Dorsey, JG
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) : 143 - 153
  • [8] Shape Selectivity in Reversed-Phase Liquid Chromatography
    Lippa, Katrice A.
    Rimmer, Catherine A.
    Sander, Lane C.
    ADVANCES IN CHROMATOGRAPHY, VOL 46, 2008, 46 : 235 - 303
  • [9] Simultaneous Prediction of Retention Times and Peak Shapes of Sulfonamides in Reversed-Phase High-Performance Liquid Chromatography
    Wei X.
    Pang Z.
    Fan G.
    Xu X.
    Wang L.
    Transactions of Tianjin University, 2018, 24 (3) : 256 - 262
  • [10] Simultaneous Prediction of Retention Times and Peak Shapes of Sulfonamides in Reversed-Phase High-Performance Liquid Chromatography
    Xiaobing Wei
    Zhengji Pang
    Guoliang Fan
    Xinhua Xu
    Lihong Wang
    Transactions of Tianjin University, 2018, 24 (03) : 256 - 262