Linear polarization optimized Stokes polarimeter based on four-quadrant detector

被引:29
作者
He, Chao [1 ,2 ]
Chang, Jintao [1 ,3 ]
Wang, Yong [1 ,3 ]
Liao, Ran [1 ]
He, Honghui [1 ]
Zeng, Nan [1 ]
Ma, Hui [1 ,3 ]
机构
[1] Tsinghua Univ, Grad Sch Shenzhen, Inst Opt Imaging & Sensing, Shenzhen Key Lab Minimal Invas Med Technol, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Phys, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
MUELLER MATRIX; LIGHT; ARRAY; TOOL;
D O I
10.1364/AO.54.004458
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A four-quadrant detector (4QD) consists of four well-balanced detectors. We report on a Stokes polarimeter with optimal linear polarization measurements based on a 4QD. We turned the four intensity-detection channels into four polarization-analyzing channels by placing four polarizers and one quarter-wave plate in front of the individual detectors. An optimization method for the four polarization-analyzing channels is proposed to improve measurement accuracy. Considering applications in favor of linear polarization measurements instead of global optimization for all the possible states of polarization (SOP), we optimize the polarimeter first for the linear polarization components and then for the circular polarization component. The polarimeter is capable of simultaneous measurements of fast varying SOP with improved performance for the linear polarizations. (C) 2015 Optical Society of America
引用
收藏
页码:4458 / 4463
页数:6
相关论文
共 22 条
[1]  
AMBIRAJAN A, 1995, OPT ENG, V34, P1651, DOI 10.1117/12.202093
[2]  
Azzam R. M. A., 1982, INT J OPT, V29, P685
[3]   ARRANGEMENT OF 4 PHOTODETECTORS FOR MEASURING THE STATE OF POLARIZATION OF LIGHT [J].
AZZAM, RMA .
OPTICS LETTERS, 1985, 10 (07) :309-311
[4]   Single-shot spatially modulated Stokes polarimeter based on a GRIN lens [J].
Chang, Jintao ;
Zeng, Nan ;
He, Honghui ;
He, Yonghong ;
Ma, Hui .
OPTICS LETTERS, 2014, 39 (09) :2656-2659
[5]  
Chipman R.A., 2009, Handbook of Optics, V1, p15.1
[6]   Mueller matrix polarimetry for differentiating characteristic features of cancerous tissues [J].
Du, E. ;
He, Honghui ;
Zeng, Nan ;
Sun, Minghao ;
Guo, Yihong ;
Wu, Jian ;
Liu, Shaoxiong ;
Ma, Hui .
JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (07)
[7]   Tissue polarimetry: concepts, challenges, applications, and outlook [J].
Ghosh, Nirmalya ;
Vitkin, I. Alex .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (11)
[8]   Fabrication of a dual-tier thin film micropolarization array [J].
Gruev, Viktor ;
Ortu, Alessandro ;
Lazarus, Nathan ;
Van der Spiegel, Jan ;
Engheta, Nader .
OPTICS EXPRESS, 2007, 15 (08) :4994-5007
[9]   Imaging human epithelial properties with polarized light-scattering spectroscopy [J].
Gurjar, RS ;
Backman, V ;
Perelman, LT ;
Georgakoudi, I ;
Badizadegan, K ;
Itzkan, I ;
Dasari, RR ;
Feld, MS .
NATURE MEDICINE, 2001, 7 (11) :1245-1248
[10]   Application of sphere-cylinder scattering model to skeletal muscle [J].
He, Honghui ;
Zeng, Nan ;
Liao, Ran ;
Yun, Tianliang ;
Li, Wei ;
He, Yonghong ;
Ma, Hui .
OPTICS EXPRESS, 2010, 18 (14) :15104-15112