Magnetic Coil Design for Evaluating the Response of the Spinal Cord during Magnetic Stimulation

被引:0
|
作者
Cretu, Mihaela [1 ]
Ciupa, Radu V. [1 ]
机构
[1] Tech Univ Cluj Napoca, Electrotech & Measurements Dept, G Baritiu St 26-28, Cluj Napoca 400027, Romania
来源
2014 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE) | 2014年
关键词
magnetic stimulation; figure-of-eight coil; spinal cord stimulation; induced electric field; ELECTRIC-FIELD;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The purpose of this paper is to evaluate the response of the spinal cord and nearby area during lumbar magnetic stimulation. One of the most important issues about magnetic stimulation of nervous tissue is the lack of precision in the stimulated region. Based on the experimental measurements performed in cooperation with the Medical University of Vienna, the figure-of-eight coil configuration was proved to be not so efficient in spinal cord stimulation (its inability to specifically stimulate the target tissue, without activating the surrounding areas). In order to obtain the best results in stimulation, the electric circuit of the magnetic stimulator must be optimized (LRC series circuit). The most important is to establish an adequate design of the inductive coil in accordance with the medical application that is used. So, starting from these considerations, the present work aims to find a suitable design of magnetic coil capable to trigger stimulation of the spinal cord.
引用
收藏
页码:237 / 240
页数:4
相关论文
共 50 条
  • [21] Effect of coil positioning and orientation of the quadruple butterfly coil during transcranial magnetic stimulation
    Afuwape, Oluwaponmile Faith
    Rastogi, Priyam
    Jiles, David
    AIP ADVANCES, 2021, 11 (01)
  • [22] Coil optimization for magnetic brain stimulation
    Jarmo Ruohonen
    Juha Virtanen
    Risto J. Ilmoniemi
    Annals of Biomedical Engineering, 1997, 25 : 840 - 849
  • [23] Theoretical Analysis and Design of an Innovative Coil Structure for Transcranial Magnetic Stimulation
    Zhang, Naming
    Wang, Ziang
    Shi, Jinhua
    Ning, Shuya
    Zhang, Yukuo
    Wang, Shuhong
    Qiu, Hao
    APPLIED SCIENCES-BASEL, 2021, 11 (04): : 1 - 13
  • [24] Circuit and Coil Design for In-Vitro Magnetic Neural Stimulation Systems
    Basham, Eric
    Yang, Zhi
    Liu, Wentai
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2009, 3 (05) : 321 - 331
  • [25] Simulation design and experimental study of magnetic stimulation coil for robot pigeon
    Xu M.
    Pu X.
    Chang M.
    Song Y.
    Ma F.
    Huai R.
    Yang J.
    Chang H.
    Shao F.
    Wang H.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2023, 40 (01): : 141 - 148
  • [26] Coil optimization for magnetic brain stimulation
    Ruohonen, J
    Virtanen, J
    Ilmoniemi, RJ
    ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (05) : 840 - 849
  • [27] A 3-D differential coil design for localized magnetic stimulation
    Hsu, KH
    Durand, DM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (10) : 1162 - 1168
  • [28] EFFECTS OF COIL DESIGN ON DELIVERY OF FOCAL MAGNETIC STIMULATION - TECHNICAL CONSIDERATIONS
    COHEN, LG
    ROTH, BJ
    NILSSON, J
    DANG, N
    PANIZZA, M
    BANDINELLI, S
    FRIAUF, W
    HALLETT, M
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1990, 75 (04): : 350 - 357
  • [29] A 3D differential coil design for localized magnetic stimulation
    Hsu, KH
    Durand, DM
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 645 - 648
  • [30] Mapping location of excitation during magnetic stimulation: Effects of coil position
    Srikantan S. Nagarajan
    Dominique M. Durand
    Kai Hsuing-Hsu
    Annals of Biomedical Engineering, 1997, 25 : 112 - 125