Effects of grid-type shear connector arrangements used for insulated concrete sandwich wall panels with a low aspect ratio

被引:17
作者
Choi, Insub [1 ]
Kim, JunHee [1 ]
Kim, DongWon [1 ]
Park, JongSoo [1 ]
机构
[1] Yonsei Univ, Dept Architecture & Architectural Engn, Seoul 03722, South Korea
基金
新加坡国家研究基金会;
关键词
Unidirectional arrangement; Bidirectional arrangement; Glass-fiber-reinforced polymer (GFRP) shear grid; Composite behavior; Insulated concrete sandwich wall panel; COMPOSITE BEHAVIOR; FLEXURAL RESPONSE; PRECAST; PERFORMANCE;
D O I
10.1016/j.jobe.2021.103754
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Insulated concrete sandwich wall panels (ICSWPs), in which low thermal conductivity insulation is inserted between concrete wythes, can minimize the heat loss of building envelopes, and glass fiber-reinforced polymer (GFRP) grids are used to enhance both the structural and thermal performances of ICSWPs. For ICSWPs with low aspect ratios similar to a two-way slab, while bidirectional arrangements of shear grids may be considered based on two-way load transfers, unidirectional arrangements could be economically advantageous due to easier assembly of insulation and grids. This study aims to investigate the effects of grid-type shear connector arrangements on composite behaviors of ICSWPs. Bending tests were performed on four full-scale specimens to examine crack loads, stiffnesses, and strengths. Test variables consisted of GFRP grid arrangements and quantity of GFRP grids. The GFRP grid arrangements were divided into the unidirectional arrangement-installation of GFRP grids in only shorter span direction-and the bidirectional arrangement-installation of GFRP grids in both shorter and longer span directions. Major and minor axes were investigated by measuring radius of curvatures and slips in two perpendicular axes. The results revealed one-way slab behavior, with about nine times greater radius of curvature in minor axis than in major axis. As the result of quantifying degree of composite actions, the bidirectional arrangement in ICSWP demonstrated enhanced serviceability regarding crack loads and stiffness but had lower strength performance. Since the unidirectional arrangement in ICSWP exhibited acceptable composite actions conforming to the design criteria even with 11.4% less quantity of GFRP grid than the bidirectional arrangement, unidirectional installations of GFRP grid could be efficient design options of ICSWPs with low aspect ratios.
引用
收藏
页数:19
相关论文
共 62 条
[1]   Properties evaluation of fiber reinforced polymers and their constituent materials used in structures - A review [J].
Abbood, Imad Shakir ;
Odaa, Sief Aldeen ;
Hasan, Kamalaldin F. ;
Jasim, Mohammed A. .
MATERIALS TODAY-PROCEEDINGS, 2021, 43 :1003-1008
[2]   Experimental investigation of fire effects on ductility and stiffness of reinforced reactive powder concrete columns under axial compression [J].
Abdulraheem, Mustafa S. ;
Kadhum, Mohammed M. .
JOURNAL OF BUILDING ENGINEERING, 2018, 20 :750-761
[3]  
Abergel T., 2019, GLOBAL STATUS REPORT
[4]  
ACI, 2019, 31819 ACI
[5]  
ACI Committee 533, 2011, 533R11 ACI
[6]  
American Society of Civil Engineers, 2016, Minimum design loads for buildings and other structures, DOI DOI 10.1061/9780784414248
[7]   Response of precast foamed concrete sandwich panels to flexural loading [J].
Amran, Y. H. Mugahed ;
Rashid, Raizal S. M. ;
Hejazi, Farzad ;
Safiee, Nor Azizi ;
Ali, A. A. Abang .
JOURNAL OF BUILDING ENGINEERING, 2016, 7 :143-158
[8]  
[Anonymous], 2015, 4401R15 ACI
[9]  
[Anonymous], 2017, KS F 2277
[10]  
[Anonymous], 2008, 4 INT C FRP COMP CIV