Variation of peak inspiratory flow through dry powder inhalers in children with stable and unstable asthma

被引:21
作者
Kamps, AWA [1 ]
Brand, PLP [1 ]
Roorda, RJ [1 ]
机构
[1] Isala Klin, Dept Pediat, Div Pediat Pulmonol, Zwolle, Netherlands
关键词
childhood asthma; dry powder inhalers; peak inspiratory flow;
D O I
10.1002/ppul.10410
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Drug release from dry powder inhalers depends for a large part on a sufficiently high peak inspiratory flow (PIF). We determined the variation of PIF through two commonly prescribed dry powder inhalers in children with asthma. We analyzed the effect of inhaler device, age, and severity of asthma symptoms on variation of PIE Fifty-eight children with asthma (4-15 years old) recorded PIF values together with asthma symptoms in a diary twice daily for 4 weeks. PIF Nas measured with a portable PIF-meter (In-Check(TM)) equipped with adapters to simulate low resistance through the Accuhaler(TM) and Turbohaler(TM) inhalers. Children generated higher PIF values through an Accuhaler adapter than through a Turbohaler adapter (95% Cl for difference, 25.7-31.7). Mean PIF values increased with age, independent of type of inhaler. The mean (SD) variation of PIF (low%high) was 72.3 (8.1)% for patients using the Accuhaler adapter, and 67.0 (14.5)% for patients using the Turbohaler adapter (mean difference, 5.2%; 95% CI, -0.9 to 1' .4). Children less than or equal to7 years of age had a significantly greater variation of PIF in addition to a lower mean PIF (P = 0.0003). PIF decreased significantly when symptoms of asthma increased (mean maximal decrease 11 l/min; P < 0.01), but the correlation between PIF and morning and evening symptoms was weak (r = -0.18 and r = -0.16, respectively). Patients who reported moderate or severe symptoms during the study period had a significantly greater variation of PIF compared to patients who remained free of symptoms or reported mild symptoms. The majority of patients generated PIF >30 I/min during the study, even when they experienced symptoms of asthma. The variation of PIF through the Accuhaler and Turbohaler adapter was significantly greater for children less than or equal to7 years of age and for patients experiencing moderate or severe symptoms of asthma. (C) 2004 wiley-Liss, Inc.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 25 条
[1]  
[Anonymous], 1995, AM J RESP CRIT CARE, V152, P1107
[2]   Fine particle mass from the Diskus inhaler and Turbuhaler inhaler in children with asthma [J].
Bisgaard, H ;
Klug, B ;
Sumby, BS ;
Burnell, PKP .
EUROPEAN RESPIRATORY JOURNAL, 1998, 11 (05) :1111-1115
[3]   LUNG DEPOSITION OF BUDESONIDE INHALED VIA TURBUHALER(R) - A COMPARISON WITH TERBUTALINE SULFATE IN NORMAL SUBJECTS [J].
BORGSTROM, L ;
BONDESSON, E ;
MOREN, F ;
TROFAST, E ;
NEWMAN, SP .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (01) :69-73
[4]   Peak flow variation in childhood asthma: correlation with symptoms, airways obstruction, and hyperresponsiveness during long term treatment with inhaled corticosteroids [J].
Brand, PLP ;
Duiverman, EJ ;
Waalkens, HJ ;
van Essen-Zandvliet, EEM ;
Kerrebijn, KF .
THORAX, 1999, 54 (02) :103-107
[5]   Peak inspiratory flow rate and slope of the inhalation profiles in dry powder inhalers [J].
Broeders, MEAC ;
Molema, J ;
Vermue, NA ;
Folgering, HTM .
EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (05) :780-783
[6]   Effect of an external resistance to airflow on the inspiratory flow curve [J].
de Koning, JP ;
van der Mark, TW ;
Coenegracht, PMJ ;
Tromp, TFJ ;
Frijlink, HW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 234 (1-2) :257-266
[7]   Inhalation characteristics and their effects on in vitro drug delivery from dry powder inhalers .2. Effect of peak flow rate (PIFR) and inspiration time on the in vitro drug release from three different types of commercial dry powder inhalers [J].
deBoer, AH ;
Gjaltema, D ;
Hagedoorn, P .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 138 (01) :45-56
[8]   Flow early in the inspiratory manoeuvre affects the aerosol particle size distribution from a Turbuhaler [J].
Everard, ML ;
Devadason, SG ;
LeSouef, PN .
RESPIRATORY MEDICINE, 1997, 91 (10) :624-628
[9]   A comparison of the performance of two modern multidose dry powder asthma inhalers [J].
Hill, LS ;
Slater, AL .
RESPIRATORY MEDICINE, 1998, 92 (01) :105-110
[10]   Mass output and particle size distribution of glucocorticosteroids emitted from different inhalation devices depending on various inspiratory parameters [J].
Kamin, WES ;
Genz, T ;
Roeder, S ;
Scheuch, G ;
Trammer, T ;
Juenemann, R ;
Cloes, RM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2002, 15 (01) :65-73