Poly-D,L-Lactide interference screws for anterior cruciate ligament reconstruction

被引:24
作者
Barber, FA [1 ]
机构
[1] Plano Orthoped & Sports Med Ctr, Plano, TX 75093 USA
关键词
anterior cruciate ligament; biodegradable polymers; PDLLA; interference screw; patellar tendon autograft;
D O I
10.1016/j.arthro.2005.04.104
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Biodegradable interference fixation screws are widely used for anterior cruciate ligament surgery. This study evaluated 2 issues: the clinical effectiveness of a poly-D,L-lactide interference screw and the radiographic response. Type of Study: Prospective case series. Methods: A prospective series of anterior cruciate ligament reconstructions fixed with poly-D(2%),L(98%)-lactide screws were evaluated at annual intervals. Inclusion criteria were unilateral knee instability, positive Lachman and pivot-shift tests, minimum age of 16 years, and adequate bone density. Exclusionary criteria included posterior cruciate ligament tears and previous ligament surgery on the same knee. Tegner, Lysholm, International Knee Documentation Committee (IKDC) activity scores, Lachman and pivot-shift tests, and radiographs were obtained. Postoperative KT-2000 examinations were performed. Results: Sixty-one patients with 63 knees met these criteria (39 male, 22 female), at an average follow-up of 24 months (range, 12 to 42 months). The average postoperative Cincinnati score was 86 (45 preoperative), median Tegner score was 6 (2 preoperative), average Lysholm score was 89 (53 preoperative), and average IKDC activity score was 3.3 out of 4 (1.5 preoperative). Two patients had positive postoperative Lachman tests (+1) with no positive pivot-shift tests. The average KT-2000 manual-maximum difference was 0.7 mm. Only 1 KT-2000 value was greater than 3 mm (4 mm). No adverse events were encountered during screw insertion and postoperative radiographs showed bone plug consolidation and tunnel obliteration with bone in-growth increasingly apparent at 2 and 3 years (significantly earlier than published reports using pure poly-L-lactide screws). Conclusions: This is the first clinical report of a poly-D(2%),L(98%)-lactide interference fixation screw. This copolymer is zinc catalyzed, instead of the conventional tin, making the polymer more hydrophilic. The "D" isomer speeds the degradation process. These screws worked well with no adverse events. Graft tunnel obliteration was observed at 2 and 3 years. Level of Evidence: Level 4, no or historical control.
引用
收藏
页码:804 / 808
页数:5
相关论文
共 35 条
  • [1] Anderson AF., KNEE SURG, V1994, P275
  • [2] Orthopaedic applications for PLA-PGA biodegradable polymers
    Athanasiou, KA
    Agrawal, CM
    Barber, FA
    Burkhart, SS
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (07) : 726 - 737
  • [3] Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws:: MR imaging follow-up
    Bach, FD
    Carlier, RY
    Elis, JB
    Mompoint, DM
    Feydy, A
    Judet, O
    Beaufils, P
    Vallée, C
    [J]. RADIOLOGY, 2002, 225 (02) : 541 - 550
  • [4] Barber FA, 2000, BIOMATERIALS, V21, P2623
  • [5] PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW
    BARBER, FA
    ELROD, BF
    MCGUIRE, DA
    PAULOS, LE
    [J]. ARTHROSCOPY, 1995, 11 (05): : 537 - 548
  • [6] The effect of outlet fixation on tunnel widening
    Barber, FA
    Spruill, B
    Sheluga, M
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (05) : 485 - 492
  • [7] Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation
    Barber, FA
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (04) : 360 - 367
  • [8] Barber FA, 1999, TECH ORTHOP, V14, P34
  • [9] A new bioabsorbable interference screw: Preliminary results of a prospective, multicenter, randomized clinical trial
    Benedetto, KP
    Fellinger, M
    Lim, TE
    Passler, JM
    Schoen, JL
    Willems, WJ
    [J]. ARTHROSCOPY, 2000, 16 (01): : 41 - 48
  • [10] INTENSE GRANULOMATOUS INFLAMMATORY LESIONS ASSOCIATED WITH ABSORBABLE INTERNAL-FIXATION DEVICES MADE OF POLYGLYCOLIDE IN ANKLE FRACTURES
    BOSTMAN, OM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (278) : 193 - 199