Individual kidney blood flow measured with contrast-enhanced first-pass perfusion MR imaging

被引:22
作者
Martin, Diego R. [1 ]
Sharma, Puneet [1 ]
Salman, Khalil [1 ]
Jones, Richard A. [1 ,2 ]
Grattan-Smith, J. Damien [1 ,2 ]
Mao, Hui [1 ]
Lauenstein, Thomas C. [1 ]
Burrow, Bobbie K. [1 ]
Tudorascu, Dana L. [1 ]
Votaw, John R. [1 ]
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Childrens Hosp Atlanta, Dept Radiol, Atlanta, GA USA
关键词
D O I
10.1148/radiol.2461062129
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study design was HIPAA-compliant and approved by the Institutional Review Board, with all participants providing signed informed consent prior to the study. The purpose of this study was to prospectively evaluate the feasibility of determining renal blood flow (RBF) by using a technique based on intravenous administration of gadolinium chelate and evaluation of first-pass gadolinium chelate perfusion by using highly accelerated three-dimensional (3D) gradient-echo magnetic resonance (MR) imaging of the kidney in freely breathing subjects. Flow is determined with Kety-Schmidt formalism by modeling the uptake of gadolinium chelate in the kidney prior to its leaving through the venous system. Validation of the gadolinium chelate perfusion technique is based on comparison of values determined for participants with phase-contrast gradient-echo imaging. The model fit to the measured data is excellent over the first 7-8 seconds of gadolinium chelate uptake and diverges after its appearance in the renal vein. The perfusion data analysis technique showed less than 10% interobserver variation. The average difference between phase-contrast and gadolinium chelate perfusion measurements was 0.08 mL/sec (95% confidence interval: -3.73, 3.58) for left and right kidneys. This study demonstrates feasibility of the gadolinium chelate perfusion method for RBF measurement and discusses potential applications. (c) RSNA, 2008.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 34 条
[1]   Renal allograft hemodynamic and diameter changes after living donor transplantation [J].
Ardalan, MR ;
Tarzamni, MK .
TRANSPLANTATION PROCEEDINGS, 2006, 38 (02) :388-389
[2]   Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: Normal values and reproducibility [J].
Bax, L ;
Bakker, CJG ;
Klein, WM ;
Blanken, N ;
Beutler, JJ ;
Mali, WPTRM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (06) :807-814
[3]   Measurement of spin-lattice relaxation times with FLASH for dynamic MRI of the breast [J].
Brookes, JA ;
Redpath, TW ;
Gilbert, FJ ;
Needham, G ;
Murray, AD .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819) :206-214
[4]   Estimation of extraction fraction (EF) and glomerular filtration rate (GFR) using MRI: Considerations derived from a new Gd-chelate biodistribution model simulation [J].
Buonocore, MH ;
Katzberg, RW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (05) :651-666
[5]   Phase-contrast magnetic resonance flow quantification in renal arteries -: Comparison with 133Xenon washout measurements [J].
de Haan, MW ;
van Engelshoven, JMA ;
Houben, AJHM ;
Kaandorp, DW ;
Kessels, AGH ;
Kroon, AA ;
de Leeuw, PW .
HYPERTENSION, 2003, 41 (01) :114-118
[6]   DYNAMIC GD-DTPA ENHANCED MRI MEASUREMENT OF TISSUE CELL-VOLUME FRACTION [J].
DONAHUE, KM ;
WEISSKOFF, RM ;
PARMELEE, DJ ;
CALLAHAN, RJ ;
WILKINSON, RA ;
MANDEVILLE, JB ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :423-432
[7]   Improving MR quantification of regional blood volume with intravascular T-1 contrast agents: Accuracy, precision, and water exchange [J].
Donahue, KM ;
Weisskoff, RM ;
Chesler, DA ;
Kwong, KK ;
Bogdanov, AA ;
Mandeville, JB ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :858-867
[8]   NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING [J].
DUMOULIN, CL ;
BUONOCORE, MH ;
OPSAHL, LR ;
KATZBERG, RW ;
DARROW, RD ;
MORRIS, TW ;
BATEY, C .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :370-378
[9]  
Fick A., 1855, Ann. der Phys. und Chemie, V170, P59, DOI [DOI 10.1002/ANDP.18551700105, 10.1002/andp.18551700105]
[10]   Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of gadolinium-DTPA [J].
Hackstein, N ;
Kooijman, H ;
Tomaselli, S ;
Rau, WS .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (03) :406-414