Ultrasensitive electrochemical biosensor for microRNA-377 detection based on MXene-Au nanocomposite and G-quadruplex nano-amplification strategy

被引:35
作者
Wu, Qianqing [1 ,2 ]
Li, Zhenhui [3 ]
Liang, Qianwei [2 ]
Ye, Rongkai [2 ]
Guo, Shuzhou [2 ]
Zeng, Xiaobing [2 ]
Hu, Jianqiang [2 ]
Li, Aiqing [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Guangdong Prov Inst Nephrol, Natl Clin Res Ctr Kidney Dis,State Key Lab Organ F, Guangzhou 510515, Peoples R China
[2] South China Univ Technol, Sch Chem & Chem Engn, Key Lab Fuel Cell Technol Guangdong Prov, Guangzhou 510641, Peoples R China
[3] Shishi Gen Hosp, Dept Nephrol, Quanzhou 362700, Shishi, Peoples R China
关键词
MXene; Au nanocomposites; G-quadruplex; MicroRNA-377; Electrochemical biosensor; Nano; -amplification; NANOMATERIALS; BIOMARKERS; TARGET; CANCER; H2O2;
D O I
10.1016/j.electacta.2022.140945
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
MicroRNAs (miRNAs) are considered as potential biomarkers for early diagnosis and prognostic assessment of diabetic nephropathy. In this work, an electrochemical biosensor for ultrasensitive detection of miRNA-377 was constructed based on MXene-Au nanocomposites and G-quadruplex nano-amplification strategy. As a promising nanocarrier, taking advantage of leveraging synergistic effects between Au nanoparticles (AuNPs) and MXene nanosheet, MXene-Au nanocomposites exhibited excellent electronic conductivity and provided massive active sites for DNA capture probe immobilization by Au-S bonds. AuNPs modified with Guanine-rich sequence DNA detection probes were designed as signal amplification nano-labels. Specifically, by inducing the transition of Guanine-rich detection probes to G-quadruplex, the strong affinity interaction between methylene blue and G-quadruplex could not only reflect trace concentration information of miRNA-377, but also lead to the further enhancement of electrochemical signal (2.7-fold). As a result, this newly designed biosensor exhibited superior sensing performance with a wide linear range from 10 aM to 100 pM and the limit of detection was as low as 1.35 aM. Compared with biosensors based on other nanocomposites and reported miRNA-377 biosensors, the pro-posed sensing platform did not require any thermal cycling or reverse transcription process, meeting the miRNA sensing requirements of convenient, sensitive, specific and stable. Furthermore, the as-constructed biosensor also displayed good selectivity, which was applied to accurate detection of miRNA-377 in human serum samples with satisfactory sensitivity, suggesting the biosensor system has promising applications in biological researches and early clinical diagnosis for diabetic nephropathy.
引用
收藏
页数:8
相关论文
共 35 条
  • [1] A G-quadruplex DNA-based, Label-Free and Ultrasensitive Strategy for microRNA Detection
    Yan, Li
    Yan, Yiyong
    Pei, Lei
    Wei, Wei
    Zhao, Jing
    SCIENTIFIC REPORTS, 2014, 4
  • [2] An electrochemical biosensor for highly sensitive detection of microRNA-377 based on strand displacement amplification coupled with three-way junction
    Hu, Rong
    Wang, Ganglin
    Yuan, Rui
    Xu, Yongjie
    Yu, Tianxiao
    Zhong, Liang
    Zhou, Qin
    Ding, Shijia
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 789 : 160 - 166
  • [3] High specific microRNA detection based on G-quadruplex sensitive fluorescence under isothermal amplification
    Fu, Jiye
    Tu, Tiantian
    Wen, Tian
    Zhang, Qiongdan
    Huang, Chao
    Lu, Zuhong
    Tu, Jing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 51 (08)
  • [4] An electrochemical biosensor for the detection of Pb2+ based on G-quadruplex DNA and gold nanoparticles
    Xu, Shengpan
    Chen, Xiaojun
    Peng, Gang
    Jiang, Ling
    Huang, He
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (23) : 5879 - 5887
  • [5] An electrochemical biosensor for the detection of Pb2+ based on G-quadruplex DNA and gold nanoparticles
    Shengpan Xu
    Xiaojun Chen
    Gang Peng
    Ling Jiang
    He Huang
    Analytical and Bioanalytical Chemistry, 2018, 410 : 5879 - 5887
  • [6] A simple and ultrasensitive electrochemical biosensor for detection of microRNA based on hybridization chain reaction amplification
    Zhai, Qian
    He, Yun
    Li, Xiaolu
    Guo, Jing
    Li, Shengqiang
    Yi, Gang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 758 : 20 - 25
  • [7] An ultrasensitive electrochemical biosensor based on multifunctional hemin/G-quadruplex nanowires simultaneously served as bienzyme and direct electron mediator for detection of lead ion
    Qing, Min
    Yuan, Yali
    Cai, Wei
    Xie, Shunbi
    Tang, Ying
    Yuan, Ruo
    Zhang, Jin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 263 : 469 - 475
  • [8] A novel aptasensor strategy for protein detection based on G-quadruplex and exonuclease Ⅲ-aided recycling amplification
    Huan Shi
    Tian Jin
    Jiewen Zhang
    Xiaoting Huang
    Chunyan Tan
    Yuyang Jiang
    Ying Tan
    Chinese Chemical Letters, 2020, 31 (01) : 155 - 158
  • [9] Electrochemical biosensor for DNA methyltransferase detection based on DpnI digestion triggering the formation of G-quadruplex DNAzymes
    Liu, Pei
    Liu, Min
    Yin, Hunshun
    Zhou, Yunlei
    Ai, Shiyun
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 101 - 106
  • [10] Novel electrochemical biosensing platform for microRNA detection based on G-quadruplex formation in nanochannels
    Zhao, Fei
    Zhang, Hongfang
    Zheng, Jianbin
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 327