Assessment of plutonium measurement in the femtogram range by ICP-MS;: correction from interfering polyatomic species

被引:38
作者
Pointurier, Fabien [1 ]
Hemet, Philippe [1 ]
Hubert, Amelie [1 ]
机构
[1] CEA, DAM DIF, DASE, SRCE, F-91680 Bruyeres Le Chatel, France
关键词
D O I
10.1039/b708568k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the frame of the low level plutonium measurements performed by ICP- MS on environmental samples in support of the International Atomic Energy Agency's safeguards program, we observe that background in the actinide mass range for the sample solutions is always higher than for blanks made of deionised water and ultra-pure grade nitric acid. This additional background is due to polyatomic species including heavy metals like Pb, Hg, Ir, etc., which remain in sample solutions despite the purification chemistry that is systematically carried out. As Pu content in the samples may be extremely low-in the femtogram (10(-15) g) range-it is of uttermost importance to estimate detection limits as accurately as possible and to minimize risks of false detections. We propose an approach that consists of systematically correcting for contributions of polyatomic species to the background. To accomplish this, it is necessary to estimate all the formation rates of polyatomic species consisting of a "heavy metal'' (from Hf to Bi) and one or more atoms, such as O, N, Ar, Cl, etc., that have total masses corresponding to those of Pu isotopes. Although the formation rates can vary largely with settings and analytical conditions, this study allows identification of the higher formation rates. The analytical procedure must also include, in addition to Pu and background masses, the measurement of one isotope for each "heavy metal''. Starting from examples of real sample measurements, we compare various calculation models for background and detection limits and prove that the one taking into account corrections from polyatomic interferences gives the most accurate results and minimises the risk of false detection for ultra low-level Pu measurements in the fg range.
引用
收藏
页码:94 / 102
页数:9
相关论文
共 21 条
[1]   Evaluation of a single collector, double focusing sector field inductively coupled plasma mass spectrometer for the determination of U and Pu concentrations and isotopic compositions at trace level [J].
Baglan, N ;
Hemet, P ;
Pointurier, F ;
Chiappini, R .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 261 (03) :609-617
[2]   Environmental monitoring of plutonium at ultratrace level in natural water (Sea of Galilee-Israel) by ICP-SFMS and MC-ICP-MS [J].
Becker, JS ;
Zoriy, M ;
Halicz, L ;
Teplyakov, N ;
Müller, C ;
Segal, I ;
Pickhardt, C ;
Platzner, IT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (09) :1257-1261
[3]   Application of double-focusing sector field ICP mass spectrometry with shielded torch using different nebulizers for ultratrace and precise isotope analysis of long-lived radionuclides - Invited lecture [J].
Becker, JS ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1493-1500
[4]  
Becker JS, 2002, SPECTROSC EUROPE, V14, P8
[5]   Optimisation and application of ICP-MS and alpha-spectrometry for determination of isotopic ratios of depleted uranium and plutonium in samples collected in Kosovo [J].
Boulyga, SF ;
Testa, C ;
Desideri, D ;
Becker, JS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (11) :1283-1289
[6]   240Pu/239Pu isotopic ratios and 239+240Pu total measurements in surface and deep waters around Mururoa and Fangataufa atolls compared with Rangiroa atoll (French Polynesia) [J].
Chiappini, R ;
Pointurier, F ;
Millies-Lacroix, JC ;
Lepetit, G ;
Hemet, P .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 238 :269-276
[7]   Resolving global versus local/regional Pu sources in the environment using sector ICP-MS [J].
Ketterer, ME ;
Hafer, KM ;
Link, CL ;
Kolwaite, D ;
Wilson, J ;
Mietelski, JW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) :241-245
[8]   Concentration of plutonium in squids collected from Japanese inshore measured by HR-ICP-MS, 1981-2000 [J].
Kishimoto, T ;
Sanada, T ;
Sato, K ;
Higuchi, H .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (02) :395-398
[9]  
MAGARA M, 2004, WINT C PLASM SPECTR
[10]   Determination of plutonium concentration and its isotopic ratio in environmental materials by ICP-MS after separation using ion-exchange and extraction chromatography [J].
Muramatsu, Y ;
Uchida, S ;
Tagami, K ;
Yoshida, S ;
Fujikawa, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) :859-865