Calculation method for the torsional bearing capacity of composite girders with CSW-CFST truss chords

被引:7
作者
Huang, Hanhui [1 ]
Chen, Kangming [1 ]
Wu, Qingxiong [1 ]
Nakamura, Shozo [2 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, 2 Xueyuan Rd, Fuzhou 350108, Peoples R China
[2] Nagasaki Univ, Dept Civil & Environm Engn, 1-14 Bunkyo Machi, Nagasaki 8528521, Japan
基金
中国国家自然科学基金;
关键词
Composite girders; Corrugated steel webs; CFST truss chords; Compound stiffness; Torsional behavior; Bearing capacity; Calculating method; CORRUGATED STEEL WEBS; MULTICELL BOX-GIRDERS; BRIDGES; BEHAVIOR;
D O I
10.1016/j.engstruct.2022.114830
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Torsional behavior tests and a theoretical analysis were conducted on the composite girders with corrugated steel webs and concrete-filled steel tubular (CSW-CFST) truss chords. Their performance was compared with that of composite girders with circular hollow section (CSW-CHS) truss chords and composite box girders with CSW-CFST chords. The study revealed the influence of the concrete in the chord and the sectional form of the composite girders on their twist failure mode and torsional behavior. The test results showed that the sectional form of composite girders with CSW-CFST truss chords can perform as well as closed box cross-sections. The point of twist failure was found to be when the concrete roof obliquely cracked with an angle of 45 degrees between the crack and the girder axis and the rebar had already yielded. The concrete in the chord contributes to the torsional stiffness and bearing capacity of composite girders. The paper puts forward a method for calculating the compound stiffness of CFST specimens by superposing their linear stiffness. Then, on the basis of the four types of twist failure that can affect composite girders with CSW-CFST truss chords, a method for calculating their torsional bearing capacity is proposed. The deviation between the results acquired using the proposed method and the results from the tests and a finite element analysis is less than 8.5%.
引用
收藏
页数:16
相关论文
共 50 条
[11]   THE MULTI-FUNCTIONAL MODELLING SHEAR LAG METHOD FOR ACCURATE CALCULATION OF STATIC RESPONSE AND ACCORDION EFFECT OF IMPROVED COMPOSITE BOX GIRDERS [J].
Gan, Ya-nan ;
Zhang, Zi-chen ;
Wang, Gen-hui .
BALTIC JOURNAL OF ROAD AND BRIDGE ENGINEERING, 2023, 18 (01) :1-17
[12]   Experimental and analytical studies on bearing capacity of bolt connected composite plate girders [J].
Zhu, Yiyun ;
Zhao, Jincheng .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2017, 17 (04) :1317-1329
[13]   Experimental and analytical studies on bearing capacity of bolt connected composite plate girders [J].
Yiyun Zhu ;
Jincheng Zhao .
International Journal of Steel Structures, 2017, 17 :1317-1329
[14]   Calculation Method for Residual Bearing Capacity of Composite Beams with Studs Considering Fatigue Damage [J].
Xiang Y. ;
He B. .
Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2020, 47 (09) :33-39
[15]   A design model to determine the shear load capacity of reinforced concrete chords of composite girders in the area of large web openings [J].
Balzer, Christian ;
Schnell, Juergen .
BETON- UND STAHLBETONBAU, 2014, 109 (03) :158-169
[16]   Scour effects on the bearing capacity of monopile-wheel composite foundations under lateral and torsional loads [J].
Zou, Xinjun ;
Chen, Shun ;
Yang, Zijian ;
Tu, Xinyao .
OCEAN ENGINEERING, 2024, 292
[17]   Error analysis of superposition method in bearing capacity calculation [J].
Chen, Le-Yi .
PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 :3044-3047
[18]   A bearing capacity calculation method for soil reinforced with a geocell [J].
Avesani Neto, J. O. ;
Bueno, B. S. ;
Futai, M. M. .
GEOSYNTHETICS INTERNATIONAL, 2013, 20 (03) :129-142
[19]   An accessible calculation method of the bearing capacity of shallow foundations on anisotropic rock masses [J].
Galindo, R. A. ;
Millan, M. A. .
COMPUTERS AND GEOTECHNICS, 2021, 131
[20]   Negative bending capacity prediction of composite girders based on continuous strength method [J].
Yang, Fei ;
Liu, Yuqing ;
Xin, Haohui .
THIN-WALLED STRUCTURES, 2018, 129 :278-288