Mechanical circulatory support devices experience a wide range of operating conditions during patient use. Since its first implant in June 2000, the Jarvik 2000 left ventricular assist device has witnessed systematic stepwise modifications to reduce the risk of serious adverse events and improve patient outcomes. Over time, clinical experience revealed a number of low-incidence failure modes that presented opportunities for improvement. Design changes have included, but are not limited to, a Y cable to permit battery changes without pump stoppage, increased pull strength of external cables from 35 to 200 lbs, an intermittent low-speed controller to improve aortic root washout, sintered titanium microsphere surface on the pump housing to prevent apical thrombus, and novel cone bearings to reduce thrombus formation. In summary, real world conditions challenge devices in ways that laboratory or animal experiments do not. Thorough case reviews have led to many improvements as the Jarvik 2000 continues through its second decade of implants.
引用
收藏
页码:827 / 830
页数:4
相关论文
共 18 条
  • [1] Initial experience with non-thoracic, extraperitoneal, off-pump insertion of the Jarvik 2000 Heart in patients with previous median sternotomy
    Frazier, O. H.
    Gregoric, Igor D.
    Cohn, William E.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (05) : 499 - 503
  • [2] Biventricular assistance with the Jarvik FlowMaker: A case report
    Frazier, OH
    Myers, TJ
    Gregoric, I
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (04) : 625 - 626
  • [3] Frazier OH, 2003, ANN SURG, V237, P631, DOI 10.1097/00000658-200305000-00005
  • [4] Frazier OH, 2003, ANN SURG, V237, P636
  • [5] Right coronary thrombosis in patient supported by Jarvik 2000 left ventricular assist device
    Gazzoli, Fabrizio
    Panzavolta, Marco
    Grande, Antonino Massimiliano
    Vigano, Mario
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 1076 - 1076
  • [6] Patient-Controlled Conditioning for Left Ventricular Assist Device-Induced Myocardial Recovery
    Healy, Aaron H.
    Koliopoulou, Antigoni
    Drakos, Stavros G.
    McKellar, Stephen H.
    Stehlik, Josef
    Selzman, Craig H.
    [J]. ANNALS OF THORACIC SURGERY, 2015, 99 (05) : 1794 - 1796
  • [7] Evaluation of platelet activation in patients supported by the Jarvik 2000 high-rotational speed impeller ventricular assist device
    Loeffler, Christoph
    Straub, Andreas
    Bassler, Nicole
    Pernice, Katharina
    Beyersdorf, Friedhelm
    Bode, Christoph
    Siegenthaler, Michael P.
    Peter, Karlheinz
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (03) : 736 - 741
  • [8] Comparison of Intraplatelet Reactive Oxygen Species, Mitochondrial Damage, and Platelet Apoptosis After Implantation of Three Continuous Flow Left Ventricular Assist Devices: HeartMate II, Jarvik 2000, and HeartWare
    Mondal, Nandan K.
    Sorensen, Erik N.
    Feller, Erika D.
    Pham, Si M.
    Griffith, Bartley P.
    Wu, Zhongjun J.
    [J]. ASAIO JOURNAL, 2015, 61 (03) : 244 - 252
  • [9] Off-pump insertion of continuous flow left ventricular assist devices
    Selzman, Craig H.
    Sheridan, Brett C.
    [J]. JOURNAL OF CARDIAC SURGERY, 2007, 22 (04) : 320 - 322
  • [10] University of Maryland Surgical Experience With the Jarvik 2000 Axial Flow Ventricular Assist Device
    Sorensen, Erik N.
    Pierson, Richard N., III
    Feller, Erika D.
    Griffith, Bartley P.
    [J]. ANNALS OF THORACIC SURGERY, 2012, 93 (01) : 133 - 140