Development and evaluation of real-time polymerase chain reaction assays on whole blood and paraffin-embedded tissues for rapid diagnosis of human brucellosis

被引:64
作者
Kattar, Mireille M. [1 ]
Zalloua, Pierre
Araj, George F.
Samaha-Kfoury, Joumana
Shbaklo, Hadia
Kanj, Souha S.
Khalife, Simon
Deeb, Mary
机构
[1] Amer Univ Beirut, Dept Pathol & Lab Med, Beirut 11072020, Lebanon
[2] Amer Univ Beirut, Dept Internal Med, Div Infect Dis SSK, Beirut 11072020, Lebanon
[3] Amer Univ Beirut, Dept Epidemiol & Populat Hlth, Beirut 11072020, Lebanon
[4] Reg World Hlth Org Collaborating Ctr Human Brucel, Beirut, Lebanon
[5] Chron Care Ctr, Genet Res Lab, Beirut, Lebanon
关键词
human brucellosis; real-time PCR; whole blood; archived tissue;
D O I
10.1016/j.diagmicrobio.2007.04.002
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
This study aimed at developing a real-time polymerase chain reaction (PCR) assay for the rapid diagnosis of human brucellosis on clinical specimens. Three assays with hybridization probe detection on the LightCycler (TM) instrument were developed and compared targeting the 16S-23S internal transcribed spacer region (ITS) and the genes encoding for omp25 and omp31, All assays showed 100% analytical sensitivity and 100% specificity when tested on 28 consecutive clinical isolates of Brucella sp. and 19 clinical isolates of common Gram-negative and Gram-positive bacterial pathogens, respectively. The ITS assay was the most sensitive with a limit of detection of 2 genome equivalents per PCR reaction. This assay was then clinically validated prospectively with 354 samples (351 whole blood samples and 3 paraffin-embedded tissues) collected from 340 patients, 24 samples from patients with active brucellosis including 2 relapsing cases, 31 with treated brucellosis, and 299 seronegative patients where brucellosis was initially suspected. The clinical sensitivity, specificity, and positive and negative predictive values of the ITS assay were 66.7%, 99.7%, 94.1 %, and 97.6%, compared with culture at 77%, 100%, 100%, and 97.3%, respectively. The difference in sensitivity between culture and ITS-PCR was not statistically significant (P = 0.71). Both relapsing cases were PCR positive. Treated patients were PCR negative. All 3 assays were positive on tissue samples, but the omp25 and omp31 assays did not detect Brucella sp. DNA in blood samples. Because omp31 is not present in Brucella abortus, these data indicate that the 28 tested isolates are most likely Brucella melitensis. ITS-PCR is rapid and could augment the clinical laboratory diagnosis of human brucellosis. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 50 条
  • [41] RICHMOND YJ, 1999, BIOSAFETY MICROBIOLO, P90
  • [42] Direct detection of Brucella spp in raw milk by PCR and reverse hybridization with 16S-23S rRNA spacer probes
    Rijpens, NP
    Jannes, G
    VanAsbroeck, M
    Rossau, R
    Herman, LMF
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1996, 62 (05) : 1683 - 1688
  • [43] SPECIFIC DETECTION OF BRUCELLA DNA BY PCR
    ROMERO, C
    GAMAZO, C
    PARDO, M
    LOPEZGONI, I
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (03) : 615 - 617
  • [44] Vizcaino N, 1996, INFECT IMMUN, V64, P3744
  • [45] Minor nucleotide substitutions in the omp31 gene of Brucella ovis result in antigenic differences in the major outer membrane protein that it encodes compared to those of the other Brucella species
    Vizcaíno, N
    Kittelberger, R
    Cloeckaert, A
    Marín, CM
    Fernández-Lago, L
    [J]. INFECTION AND IMMUNITY, 2001, 69 (11) : 7020 - 7028
  • [46] Application of a polymerase chain reaction enzyme immunoassay in peripheral whole blood and serum specimens for diagnosis of acute human brucellosis
    Vrioni, G
    Gartzonika, C
    Kostoula, A
    Boboyianni, C
    Papadopoulou, C
    Levidiotou, S
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2004, 23 (03) : 194 - 199
  • [47] Continuous fluorescence monitoring of rapid cycle DNA amplification
    Wittwer, CT
    Herrmann, MG
    Moss, AA
    Rasmussen, RP
    [J]. BIOTECHNIQUES, 1997, 22 (01) : 130 - &
  • [48] The LightCycler(TM) a microvolume multisample fluorimeter with rapid temperature control
    Wittwer, CT
    Ririe, KM
    Andrew, RV
    David, DA
    Gundry, RA
    Balis, UJ
    [J]. BIOTECHNIQUES, 1997, 22 (01) : 176 - 181
  • [49] Detection of Brucellae in blood cultures
    Yagupsky, P
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (11) : 3437 - 3442
  • [50] Serum is the preferred clinical specimen for diagnosis of human brucellosis by PCR
    Zerva, L
    Bourantas, K
    Mitka, S
    Kansouzidou, A
    Legakis, NJ
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (04) : 1661 - 1664