Continuous acquisition scanner for whole-body multispectral optoacoustic tomography

被引:0
|
作者
Ma, Rui [1 ]
Ntziachristos, Vasilis [1 ]
Razansky, Daniel [1 ]
机构
[1] Tech Univ Munich, Inst Biol & Med Imaging, D-85764 Neuherberg, Germany
关键词
Photoacoustic imaging; Biomedical Optics; Multispectral and hyperspectral imaging; Medical and biological imaging; Medical optics instrumentation; IN-VIVO; HIGH-RESOLUTION; PHOTOACOUSTIC TOMOGRAPHY; MICROSCOPY;
D O I
10.1117/12.842776
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An essential problem dealing with three-dimensional optoacoustic imaging is the long data acquisition times associated with recording signals from multiple spatial projections, where signal averaging for each projection is applied to obtain satisfying signal-to-noise-ratio. This approach complicates acquisition and makes imaging challenging for most applications, especially for in vivo imaging and multispectral imaging. Instead we employ a herein introduced continuous data acquisition methodology that greatly shortens recording times over multiple projection angles and acquires high quality tomographic data without averaging. By this means a two dimensional image acquisition having 270 angular projections only takes about 9 seconds, while a full multispectral three dimensional image can normally take about 15 minutes to acquire with a single ultrasonic detector. The system performance is verified on tissue-mimicking phantoms containing known concentrations of fluorescent molecular agent as well as small animals.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] THE INDICATIONS OF THE WHOLE-BODY SCANNER WITH THE EXCEPTION OF ONCOLOGY
    LAVALJEANTET, M
    BUY, JN
    GAZETTE MEDICALE DE FRANCE, 1982, 89 (08): : 823 - &
  • [22] SPECIAL INDICATIONS FOR USING WHOLE-BODY SCANNER
    ROTHE, R
    SCHERER, U
    LISSNER, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1977, 127 (06): : 530 - 535
  • [23] EVALUATION OF TUMOR EXTENSION BY WHOLE-BODY SCANNER
    LAGERGREN, C
    UROLOGICAL RESEARCH, 1978, 6 (04): : 191 - 192
  • [24] EARLY EXPERIENCE WITH ELSCINT WHOLE-BODY SCANNER
    COALTER, GC
    MONKS, GK
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1976, 6 (03): : 274 - 274
  • [25] EVALUATION AND APPLICATION OF WHOLE-BODY SCINTIGRAPHIC SCANNER
    COOKE, MBD
    LOPEZMAJ.V
    KAPLAN, E
    JOURNAL OF NUCLEAR MEDICINE, 1971, 12 (06) : 426 - &
  • [26] COMPARISON OF A NEW WHOLE-BODY SCANNER WITH A LARGE CRYSTAL SCANNING CAMERA IN WHOLE-BODY IMAGING
    ELL, PJ
    MYERS, MJ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1977, 2 (04): : 281 - 284
  • [27] Teachability of multispectral optoacoustic tomography
    Li, Yi
    Grohl, Janek
    Haney, Briain
    Caranovic, Milenko
    Lorenz-Meyer, Eva
    Papatheodorou, Nikolaos
    Kempf, Julius
    Regensburger, Adrian P.
    Nedoschill, Emmanuel
    Buehler, Adrian
    Siebenlist, Gregor
    Lang, Werner
    Uder, Michael
    Neurath, Markus F.
    Waldner, Maximilian
    Knieling, Ferdinand
    Rother, Ulrich
    JOURNAL OF BIOPHOTONICS, 2024, 17 (07)
  • [28] Patient and scanner-specific variable acquisition times for whole-body PET/CT imaging
    Namias, M.
    Jeraj, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (20):
  • [29] Flash Scanning Volumetric Optoacoustic Tomography for High Resolution Whole-Body Tracking of Nanoagent Kinetics and Biodistribution
    Ron, Avihai
    Kalva, Sandeep Kumar
    Periyasamy, Vijitha
    Dean-Ben, Xose Luis
    Razansky, Daniel
    LASER & PHOTONICS REVIEWS, 2021, 15 (03)
  • [30] NEW WHOLE-BODY SCANNER - COMPARISON WITH A LARGE CRYSTAL SCANNING CAMERA IN ORGAN AND WHOLE-BODY MODE
    ELL, PJ
    MYERS, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1976, 1 (02): : 75 - 75