Reduction in early dislocation rate with large-diameter femoral heads in primary total hip arthroplasty

被引:93
作者
Peters, Christopher L.
McPherson, Edward
Jackson, Jeffrey D.
Erickson, Jill A.
机构
[1] Univ Utah, Sch Med, Dept Orthoped Surg, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Orthopaed, Salt Lake City, UT USA
[3] Ctr Arthritis, Joint Implant Surg, Los Angeles, CA USA
关键词
total hip arthroplasty; large-diameter femoral heads; dislocation; posterior approach; anterolateral approach; metal on metal;
D O I
10.1016/j.arth.2007.04.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Large-diameter femoral heads, which may reduce dislocation, are used without extensive in vivo research. Two studies were done to determine relative dislocation rates. Study 1 compared dislocation rates in primary total hip arthroplasties (THAs) using 28- or 38-mm heads. Study 2 evaluated dislocation rates in large-diameter (38-56 mm) metal-on-metall heads. in study 1, 136 patients with 38-mm heads via posterior approach and 160 patients with 28-mm heads via Hardinge approach had an average of 52 months of follow-Lip (range, 32-106 months). In study 2, 469 patients had THA with large-diameter metal-on-metal heads, with an average of 36 months of follow-up (range, 24-46 months). Harris hip scores evaluated the clinical outcomes. Study 1 had no dislocations in the 38mm group and had 4 dislocations (2.5%) in the 28-mm group (P =.12). Study 2 had 2 dislocations (0.4%). Dislocation rates in primary THA with 38-mm bearings via posterior approach are the same as 28-mm bearings via Hardinge approach. Metal-on-metal THA with 38 to 56 mm heads is also associated with low dislocation rates (0.4%) at short-term follow-up.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 27 条
[1]   Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[2]   The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[3]   Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement [J].
Beaule, PE ;
Schmalzried, TP ;
Udomkiat, P ;
Amstutz, HC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02) :256-263
[4]   The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :9-14
[5]  
Chan FW, 1999, CLIN ORTHOP RELAT R, P10
[6]   Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty [J].
Clarke, MT ;
Lee, PTH ;
Arora, A ;
Villar, RN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06) :913-917
[7]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]  
DORR LD, 1983, CLIN ORTHOP RELAT R, V173, P151
[9]  
EFTEKHAR NS, 1976, CLIN ORTHOP RELAT R, V121, P120
[10]  
FACKLER CD, 1980, CLIN ORTHOP RELAT R, V151, P169