Sustainability Analysis of Green Data Centers With CCHP and Waste Heat Reuse Systems

被引:28
作者
Wan, Jianxiong [1 ,2 ]
Zhou, Jie [1 ,2 ]
Gui, Xiang [1 ,3 ]
机构
[1] Inner Mongolia Univ Technol & Inner Mongolia Auto, Hohhot 010062, Peoples R China
[2] Technol Res Ctr Big Data Based Software Serv, Hohhot 010062, Peoples R China
[3] Massey Univ, Dept Mech & Elect Engn, SF&AT, Palmerston North, New Zealand
来源
IEEE TRANSACTIONS ON SUSTAINABLE COMPUTING | 2021年 / 6卷 / 01期
基金
中国国家自然科学基金;
关键词
Data centers; Waste heat; Resistance heating; Trigeneration; Energy management; Data center sustainability; combined cooling; heating; and power (CCHP) system; waste heat reuse (WHR); energy management; OPERATION STRATEGY; OPTIMAL-DESIGN; POWER-SYSTEM; EXERGY ANALYSIS; ENERGY; RECOVERY; OPTIMIZATION; TEMPERATURE; MODEL; FEASIBILITY;
D O I
10.1109/TSUSC.2020.2979473
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Data centers worldwide consume a large amount of energy and pose serious threats to the environment. Combined cooling, heating, and power (CCHP) and waste heat reuse (WHR) systems are two effective approaches to improve the data center energy efficiency. However, whether and to what extent the combination of them can bring further performance improvement have not been explored yet. Moreover, it is unclear how to manage the energy flow in such a hybrid system. In this article, we try to answer these questions by proposing a data center energy architecture that includes both CCHP and WHR technologies. We formulate the energy management problem as two optimization problems with different objectives. By analytically solving the optimization problems, two energy management strategies, namely, Following the electrical load with waste heat reuse (FEL-WHR) and operating cost-aware energy management with waste heat reuse (OCM-WHR), are developed. We evaluate the performance of proposed solutions by extensive simulations using a real-world workload trace from a production data center. Numerical results suggest that the CCHP and WHR technologies generally reduce the operating cost and are more environmental friendly. If the power generation efficiency of CCHP system is high, the impact of WHR will be more conspicuous (up to 8 percent improvement) and FEL-WHR is recommended because it achieves better sustainability at an operating cost comparable to OCM-WHR. Otherwise, WHR only improves the sustainability trivially, and the energy management policy should be carefully chosen according to the data center operator's objective.
引用
收藏
页码:155 / 167
页数:13
相关论文
共 59 条
[1]   Optimal design, operation and analytical criteria for determining optimal operating modes of a CCHP with fired HRSG, boiler, electric chiller and absorption chiller [J].
Afzali, Sayyed Faridoddin ;
Mahalec, Vladimir .
ENERGY, 2017, 139 :1052-1065
[2]   Performance assessment of hybrid chiller systems for combined cooling, heating and power production [J].
Ahn, Hyeunguk ;
Rim, Donghyun ;
Freihaut, James D. .
APPLIED ENERGY, 2018, 225 :501-512
[3]   Optimal design and operation of district heating and cooling networks with CCHP systems in a residential complex [J].
Ameri, Mohammad ;
Besharati, Zahed .
ENERGY AND BUILDINGS, 2016, 110 :135-148
[4]  
[Anonymous], 2011, P 3 USENIX WORKSH HO
[5]  
Araya Sebastian, 2018, 2018 17th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm). Proceedings, P850, DOI 10.1109/ITHERM.2018.8419530
[6]  
Auth C, 2017, INT EL DEVICES MEET
[7]  
Brunschwiler T, 2010, PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 8, P429
[8]   TOFFEE: Task Offloading and Frequency Scaling for Energy Efficiency of Mobile Devices in Mobile Edge Computing [J].
Chen, Ying ;
Zhang, Ning ;
Zhang, Yongchao ;
Chen, Xin ;
Wu, Wen ;
Shen, Xuemin .
IEEE TRANSACTIONS ON CLOUD COMPUTING, 2021, 9 (04) :1634-1644
[9]   Energy Efficient Dynamic Offloading in Mobile Edge Computing for Internet of Things [J].
Chen, Ying ;
Zhang, Ning ;
Zhang, Yongchao ;
Chen, Xin ;
Wu, Wen ;
Shen, Xuemin .
IEEE TRANSACTIONS ON CLOUD COMPUTING, 2021, 9 (03) :1050-1060
[10]  
Chiriac VA, 2012, INTSOC CONF THERMAL, P814, DOI 10.1109/ITHERM.2012.6231510