Determination of ascorbic acid in serum samples by screen-printed carbon electrodes modified with gold nanoparticles

被引:45
作者
Asuncion Alonso-Lomillo, M. [1 ]
Dominguez-Renedo, Olga [1 ]
Saldana-Botin, Abraham [1 ]
Julia Arcos-Martinez, M. [1 ]
机构
[1] Univ Burgos, Fac Sci, Dept Analyt Chem, Pza Misael Banuelos S-N, Burgos 09001, Spain
关键词
Ascorbic acid; Dopamine; Uric acid; Screen-printed electrodes; Multivariate regressions; FLOW-INJECTION ANALYSIS; ELECTROCHEMICAL SENSOR; URIC-ACID; AMPEROMETRIC DETERMINATION; COBALT PHTHALOCYANINE; DOPAMINE; GRAPHENE; POLYMER;
D O I
10.1016/j.talanta.2017.07.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper shows the ability of simple modified screen-printed devices for the electrochemical detection of ascorbic acid in different samples, including serum samples. Even if the presence of uric acid does not greatly affect the analysis of ascorbic acid using screen-printed carbon electrodes modified by gold nanoparticles, dopamine must be considered an interferent. Thus, the joint determination of the three compounds has been set out using methods of multivariate calibration. The validated models, built by partial least squares regressions, have been used to determine the concentration of ascorbic acid, dopamine and uric acid of spiked serum samples, with successful results.
引用
收藏
页码:733 / 737
页数:5
相关论文
共 41 条
[1]   Direct In Situ Determination of Ascorbic Acid in Fruits by Screen-Printed Carbon Electrodes Modified with Nylon-6 Nanofibers [J].
Alberto Fuenmayor, Carlos ;
Benedetti, Simona ;
Pellicano, Alessandro ;
Cosio, Maria Stella ;
Mannino, Saverio .
ELECTROANALYSIS, 2014, 26 (04) :704-710
[2]   The application of conducting polymer nanoparticle electrodes to the sensing of ascorbic acid [J].
Ambrosi, Adriano ;
Morrin, Aoife ;
Smyth, Malcolm R. ;
Killard, Anthony J. .
ANALYTICA CHIMICA ACTA, 2008, 609 (01) :37-43
[3]  
[Anonymous], 1997, 11843 ISO 1
[4]  
[Anonymous], 2000, 11843 ISO 2
[5]  
[Anonymous], 1982, STRAT CENT 16
[6]  
[Anonymous], 1991, Diseno y analisis de experimentos
[7]   Cytochrome P450 2D6 based electrochemical sensor for the determination of codeine [J].
Asturias-Arribas, Laura ;
Asuncion Alonso-Lomillo, M. ;
Dominguez-Renedo, Olga ;
Julia Arcos-Martinez, M. .
TALANTA, 2014, 129 :315-319
[8]   Screen-printed biosensor based on the inhibition of the acetylcholinesterase activity for the determination of codeine [J].
Asturias-Arribas, Laura ;
Asuncion Alonso-Lomillo, M. ;
Dominguez-Renedo, Olga ;
Julia Arcos-Martinez, M. .
TALANTA, 2013, 111 :8-12
[9]   Sensitive enzyme-biosensor based on screen-printed electrodes for Ochratoxin A [J].
Asuncion Alonso-Lomillo, M. ;
Dominguez-Renedo, Olga ;
Ferreira-Goncalves, Liliana ;
Julia Arcos-Martinez, M. .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (06) :1333-1337
[10]  
Box G. E. P., 1989, ESTADISTICA INVESTIG