Experimental study of thermal comfort in a field environment chamber with stratum ventilation system in winter

被引:37
作者
Cheng, Fanghui [1 ,2 ,3 ]
Wu, Yuxin [4 ]
Gao, Shasha [1 ,2 ,3 ]
Liao, Chunhui [5 ]
Cheng, Yong [1 ,2 ,3 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
[2] Chongqing Univ, Minist Educ, Joint Int Res Lab Green Bldg & Built Environm, Chongqing, Peoples R China
[3] Chongqing Univ, Minist Sci & Technol, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing, Peoples R China
[4] Zhejiang Sci Tech Univ, Sch Civil Engn & Architecture, Hangzhou, Zhejiang, Peoples R China
[5] Chongqing Univ Sci & Technol, Inst Hlth & Environm, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Stratum ventilation; Winter heating; Thermal comfort; Local discomfort; Subjective evaluation; AIR CHANGE EFFECTIVENESS; MIXING VENTILATION; TEMPERATURE; PERFORMANCE; HUMIDITY; OPERATION; SENSATION; EXPOSURE; ROOMS; SKIN;
D O I
10.1016/j.buildenv.2021.108445
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stratum ventilation has potentials to be used for winter heating. Both local and overall thermal perceptions are essential for ensuring indoor satisfactory thermal environments. This study aimed to comprehensively investigate the subjective perceptions in a field environment chamber heated by stratum ventilation. The chamber was configured as a two-row classroom. Eleven cases were conducted with supply air velocities of 0.8-1.4 m/s and supply air temperatures of 23-30 degrees C. With room air temperatures of approximately 20-24 degrees C, thirty-six subjects were recruited to evaluate the thermal environments. The questionnaires concerned overall thermal sensation and comfort (OTS and OTC), local thermal sensation and comfort (LTS and LTC), draft sensation, and humidity sensation. The results showed that the OTS conformed to Category C in ISO 7730. The overall discomfort was related to the OTS cooler than thermal neutrality. The LTSs of body segments fluctuated within the range of -0.7 - 0.7. Among the body segments, the head had the most significant influence on OTC, and followed by the feet. The percentage of dissatisfied due to discomfort of warm head and/or cold feet (PD) might exceed 10%, which was mainly resulted from the discomfort risk of cold feet. The relationship between PD and LTS of the feet indicated that with LTS of the feet higher than -0.5, the PD could be below 10%. With stratum ventilation for winter heating, the air movement was acceptable with draft rate less than 20%. However, the humidity environment remained to be improved by additional measures.
引用
收藏
页数:13
相关论文
共 62 条
  • [1] Experimental study on air change effectiveness: Improving air distribution with all-air heating systems
    Amai, Hideyuki
    Liu, Shichao
    Novoselac, Atila
    [J]. BUILDING AND ENVIRONMENT, 2017, 125 : 515 - 527
  • [2] Experimental study on air change effectiveness in mixing ventilation
    Amai, Hideyuki
    Novoselac, Atila
    [J]. BUILDING AND ENVIRONMENT, 2016, 109 : 101 - 111
  • [3] [Anonymous], 2020, 552020 ANSIASHRAE
  • [4] [Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
  • [5] [Anonymous], 1998, ISO 7726 ERGONOMICS
  • [6] Awbi H., 2008, Ventilation of Buildings
  • [7] A review of the performance of different ventilation and airflow distribution systems in buildings
    Cao, Guangyu
    Awbi, Hazim
    Yao, Runming
    Fan, Yunqing
    Siren, Kai
    Kosonen, Risto
    Zhang, Jianshun
    [J]. BUILDING AND ENVIRONMENT, 2014, 73 : 171 - 186
  • [8] Experimental investigation of airflow pattern and turbulence characteristics of stratum ventilation in heating mode
    Cheng, Fanghui
    Zhang, Sheng
    Gao, Shasha
    Tian, Xue
    Liao, Chunhui
    Cheng, Yong
    [J]. BUILDING AND ENVIRONMENT, 2020, 186
  • [9] Experimental investigation into the interaction between the human body and room airflow and its effect on thermal comfort under stratum ventilation
    Cheng, Y.
    Lin, Z.
    [J]. INDOOR AIR, 2016, 26 (02) : 274 - 285
  • [10] [程勇 Cheng Yong], 2017, [建筑科学, Building Science], V33, P120