Experimental study of thermal comfort in a field environment chamber with stratum ventilation system in winter

被引:37
|
作者
Cheng, Fanghui [1 ,2 ,3 ]
Wu, Yuxin [4 ]
Gao, Shasha [1 ,2 ,3 ]
Liao, Chunhui [5 ]
Cheng, Yong [1 ,2 ,3 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
[2] Chongqing Univ, Minist Educ, Joint Int Res Lab Green Bldg & Built Environm, Chongqing, Peoples R China
[3] Chongqing Univ, Minist Sci & Technol, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing, Peoples R China
[4] Zhejiang Sci Tech Univ, Sch Civil Engn & Architecture, Hangzhou, Zhejiang, Peoples R China
[5] Chongqing Univ Sci & Technol, Inst Hlth & Environm, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Stratum ventilation; Winter heating; Thermal comfort; Local discomfort; Subjective evaluation; AIR CHANGE EFFECTIVENESS; MIXING VENTILATION; TEMPERATURE; PERFORMANCE; HUMIDITY; OPERATION; SENSATION; EXPOSURE; ROOMS; SKIN;
D O I
10.1016/j.buildenv.2021.108445
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stratum ventilation has potentials to be used for winter heating. Both local and overall thermal perceptions are essential for ensuring indoor satisfactory thermal environments. This study aimed to comprehensively investigate the subjective perceptions in a field environment chamber heated by stratum ventilation. The chamber was configured as a two-row classroom. Eleven cases were conducted with supply air velocities of 0.8-1.4 m/s and supply air temperatures of 23-30 degrees C. With room air temperatures of approximately 20-24 degrees C, thirty-six subjects were recruited to evaluate the thermal environments. The questionnaires concerned overall thermal sensation and comfort (OTS and OTC), local thermal sensation and comfort (LTS and LTC), draft sensation, and humidity sensation. The results showed that the OTS conformed to Category C in ISO 7730. The overall discomfort was related to the OTS cooler than thermal neutrality. The LTSs of body segments fluctuated within the range of -0.7 - 0.7. Among the body segments, the head had the most significant influence on OTC, and followed by the feet. The percentage of dissatisfied due to discomfort of warm head and/or cold feet (PD) might exceed 10%, which was mainly resulted from the discomfort risk of cold feet. The relationship between PD and LTS of the feet indicated that with LTS of the feet higher than -0.5, the PD could be below 10%. With stratum ventilation for winter heating, the air movement was acceptable with draft rate less than 20%. However, the humidity environment remained to be improved by additional measures.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Local thermal sensation and comfort study in a field environment chamber served by displacement ventilation system in the tropics
    Cheong, K. W. D.
    Yu, W. J.
    Sekhar, S. C.
    Tham, K. W.
    Kosonen, R.
    BUILDING AND ENVIRONMENT, 2007, 42 (02) : 525 - 533
  • [2] Experimental Study on Thermal Environment and Thermal Comfort of Passenger Compartment in Winter with Personal Comfort System
    Hu, Yuxin
    Zhao, Lanping
    Xu, Xin
    Wu, Guomin
    Yang, Zhigang
    ENERGIES, 2024, 17 (09)
  • [3] Experimental study of thermal comfort in an office environment with an underfloor ventilation system
    Wan, MP
    Chao, CY
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (05) : 250 - 265
  • [4] Experimental study of local thermal comfort and ventilation performance for mixing, displacement and stratum ventilation in an office
    Tian, Xue
    Li, Bozheng
    Ma, Yuxuan
    Liu, Dong
    Li, Yongcai
    Cheng, Yong
    SUSTAINABLE CITIES AND SOCIETY, 2019, 50
  • [5] Comparison of thermal comfort between convective heating and radiant heating terminals in a winter thermal environment: A field and experimental study
    Sun, Hongli
    Yang, Zixu
    Lin, Borong
    Shi, Wenxing
    Zhu, Yingxin
    Zhao, Haitian
    ENERGY AND BUILDINGS, 2020, 224 (224)
  • [6] Assessment of thermal environment using a thermal manikin in a field environment chamber served by displacement ventilation system
    Cheong, K. W. D.
    Yu, W. J.
    Kosonen, R.
    Tham, K. W.
    Sekhar, S. C.
    BUILDING AND ENVIRONMENT, 2006, 41 (12) : 1661 - 1670
  • [7] Experimental investigation of thermal comfort with stratum ventilation using a pulsating air supply
    Tian, Xue
    Zhang, Sheng
    Lin, Zhang
    Li, Yongcai
    Cheng, Yong
    Liao, Chunhui
    BUILDING AND ENVIRONMENT, 2019, 165
  • [8] Field study on occupant comfort and the office thermal environment in rooms with displacement ventilation
    Melikov, A
    Pitchurov, G
    Naydenov, K
    Langkilde, G
    INDOOR AIR, 2005, 15 (03) : 205 - 214
  • [9] Numerical study of Indoor Air Quality and thermal comfort under stratum ventilation
    Tian, Lin
    Lin, Zhang
    Liu, Jing
    Wang, Qiuwang
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2008, 8 (7-8): : 541 - 548
  • [10] An experimental case study of natural ventilation effects on the residential thermal environment and predicted thermal comfort in Kunming
    Chen, Huai
    Ding, Xiang
    Li, Rujian
    Gong, Shuai
    Liu, Baihong
    Li, Qiong
    Gao, Wenfeng
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 56