The Effects of Air Permeability, Background Ventilation and Lifestyle on Energy Performance, Indoor Air Quality and Risk of Condensation in Domestic Buildings

被引:10
作者
Hashemi, Arman [1 ]
Khatami, Narguess [2 ]
机构
[1] Univ Cambridge, Dept Engn, Ctr Sustainable Dev, Cambridge CB2 1PZ, England
[2] Univ Loughborough, Sch Civil & Bldg Engn, Loughborough LE11 3TU, Leics, England
关键词
Air permeability; Airtightness; Condensation; Domestic buildings; Energy efficiency; Indoor air quality; Lifestyle; Natural ventilation;
D O I
10.3390/su7044022
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effective and efficient ventilation is essential when improving energy performance and Indoor Air Quality (IAQ) of buildings. Reducing air permeability can considerably improve the energy performance of buildings; however, making the buildings more airtight may result in lower rates of natural ventilation which may in turn increase the risks of condensation and unacceptable IAQ. This study evaluates the effects of different air permeability rates, background ventilation and occupants' lifestyles on the energy performance as well as the risk of condensation and CO2 concentration in domestic buildings. Dynamic computer simulations were conducted in EnergyPlus. Results indicated direct relations between the ventilation rates, energy performance and IAQ. Higher air permeability along with background ventilation resulted in considerably better IAQ while energy consumption increased by up to four times. Occupants' lifestyles were identified as a major contributor to the risk of condensation.
引用
收藏
页码:4022 / 4034
页数:13
相关论文
共 50 条
  • [21] The impact of design ventilation rates on the indoor air quality in residential buildings: An Italian case study
    Moschetti, Roberta
    Carlucci, Salvatore
    [J]. INDOOR AND BUILT ENVIRONMENT, 2017, 26 (10) : 1397 - 1419
  • [22] A pre-diagnosis model for radon potential evaluation in buildings: A tool for balancing ventilation, indoor air quality and energy efficiency
    Silva, Joaquim
    Lopes, Nuno
    Curado, Antonio
    Nunes, Leonel J. R.
    Lopes, Sergio, I
    [J]. ENERGY REPORTS, 2022, 8 : 539 - 546
  • [23] Effects of thermal mass, ventilation, and glazing orientation on indoor air temperature in buildings
    Csaky, Imre
    Kalmar, Ferenc
    [J]. JOURNAL OF BUILDING PHYSICS, 2015, 39 (02) : 189 - 204
  • [24] Ventilation Methods for Improving the Indoor Air Quality and Energy Efficiency of Multi-Family Buildings in Central Europe
    Ferdyn-Grygierek, Joanna
    Grygierek, Krzysztof
    [J]. ENERGIES, 2024, 17 (09)
  • [25] Assessment of energy efficiency measures on indoor air quality and microclimate in buildings of Liepaja municipality
    Asere, Liva
    Mols, Toms
    Blumberga, Andra
    [J]. INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, CONECT 2015, 2016, 95 : 37 - 42
  • [26] Energy Consumption and Indoor Air Quality of Different Ventilation Possibilities in a New Apartment Building
    Zogla, Gatis
    Blumberga, Andra
    [J]. ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, 2010, 4 (01) : 130 - 135
  • [27] Performance of Windcatchers in Improving Indoor Air Quality, Thermal Comfort, and Energy Efficiency: A Review
    Ma, Qingsong
    Qian, Guangwei
    Yu, Menghui
    Li, Lingrui
    Wei, Xindong
    [J]. SUSTAINABILITY, 2024, 16 (20)
  • [28] Using a ventilation controller to optimise residential passive ventilation for energy and indoor air quality
    Turner, William J. N.
    Walker, Iain S.
    [J]. BUILDING AND ENVIRONMENT, 2013, 70 : 20 - 30
  • [29] The impact of the technical requirements of the renovation grant on the ventilation and indoor air quality in apartment buildings
    Mikola, Alo
    Hamburg, Anti
    Kuusk, Kalle
    Kalamees, Targo
    Voll, Hendrik
    Kurnitski, Jarek
    [J]. BUILDING AND ENVIRONMENT, 2022, 210
  • [30] Natural ventilation and indoor air quality in educational buildings: experimental assessment and improvement strategies
    Almeida, Ricardo M. S. F.
    Pinto, Manuel
    Pinho, Paulo G.
    de Lemos, Luis T.
    [J]. ENERGY EFFICIENCY, 2017, 10 (04) : 839 - 854