Ultrasound reduces the minimum effective local anaesthetic volume compared with peripheral nerve stimulation for interscalene block

被引:98
作者
McNaught, A. [1 ]
Shastri, U. [1 ]
Carmichael, N. [1 ]
Awad, I. T. [1 ]
Columb, M. [3 ]
Cheung, J. [1 ]
Holtby, R. M. [2 ]
McCartney, C. J. L. [1 ]
机构
[1] Univ Toronto, Dept Anaesthesia, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Sunnybrook Hlth Sci Ctr, Dept Orthopaed Surg, Toronto, ON M4N 3M5, Canada
[3] Univ S Manchester Hosp, Dept Anaesthesia, Manchester M20 8LR, Lancs, England
关键词
anaesthetic techniques; regional; brachial plexus; analgesics; postoperative; BRACHIAL-PLEXUS BLOCK; LOW-DOSE BUPIVACAINE;
D O I
10.1093/bja/aeq306
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Previous studies have demonstrated that lower local anaesthetic (LA) volumes can be used for ultrasound (US)-guided interscalene brachial plexus block (ISB). However, no study has examined whether US can reduce the volume required when compared with nerve stimulation (NS) for ISB. Our aim was to do this by comparing the minimum effective analgesic volumes (MEAVs). Methods. After ethics approval and informed consent, patients undergoing shoulder surgery were recruited to this randomized, double-blind, up-down sequential allocation study. The volume used for both US and NS was dependent upon the success or failure of the previous block. Success was defined as a verbal rating score of 0/10, 30 min after surgery. Ten needle passes were allowed before defaulting to the opposite group. Patients received general anaesthesia. Pain scores and analgesic consumption were assessed by a blinded observer. Statistical comparisons of continuous variables were performed using Student's t-test and Mann-Whitney U-test as appropriate. Categorical variables were analysed using chi(2) test. MEAV values were estimated using log-transformed up-down independent pairs analysis and probit regression. Significance was assumed at P < 0.05 (two-sided). Results. The MEAV required to provide effective analgesia was significantly (P=0.034) reduced to 0.9 ml [95% confidence interval (CI) 0.3-2.8] in the US group from 5.4 ml (95% CI 3.4-8.6) in the NS group. Fewer needle passes were needed to identify the brachial plexus with US (1 vs 3; P < 0.0001) and patients had less pain at 30 min after surgery (P=0.03). Conclusions. US reduces the number of attempts, LA volume, and postoperative pain when compared with NS for ISB.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 14 条
[1]   Analgesic effect of interscalene block using low-dose bupivacaine for outpatient arthroscopic shoulder surgery [J].
Al-Kaisy, A ;
McGuire, G ;
Chan, VWS ;
Bruin, G ;
Peng, P ;
Miniaci, A ;
Perlas, A .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 1998, 23 (05) :469-473
[2]   Respiratory effects of low-dose bupivacaine interscalene block [J].
Al-Kaisy, AA ;
Chan, VWS ;
Perlas, A .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (02) :217-220
[3]  
BRULL R, 2004, ACUTE PAIN, V6, P57
[4]   Minimal Local Anesthetic Volume for Peripheral Nerve Block: A New Ultrasound-Guided, Nerve Dimension-Based Method [J].
Eichenberger, Urs ;
Stoeckli, Stefan ;
Marhofer, Peter ;
Huber, Gudrun ;
Willimann, Patrick ;
Kettner, Stephan C. ;
Pleiner, Johannes ;
Curatolo, Michele ;
Kapral, Stephan .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (03) :242-246
[5]   Continuous interscalene brachial plexus block for postoperative pain control at home: A randomized, double-blinded, placebo-controlled study [J].
Ilfeld, BM ;
Morey, TE ;
Wright, TW ;
Chidgey, LK ;
Enneking, FK .
ANESTHESIA AND ANALGESIA, 2003, 96 (04) :1089-1095
[6]   Ultrasonographic guided axillary plexus blocks with low volumes of local anaesthetics: a crossover volunteer study [J].
Marhofer, P. ;
Eichenberger, U. ;
Stoeckli, S. ;
Huber, G. ;
Kapral, S. ;
Curatolo, M. ;
Kettner, S. .
ANAESTHESIA, 2010, 65 (03) :266-271
[7]   Evidence Basis for the Use of Ultrasound for Upper-Extremity Blocks [J].
McCartney, Colin J. L. ;
Lin, Lisa ;
Shastri, Uma .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2010, 35 (02) :S10-S15
[8]  
Moayeri Nizar, 2008, Anesthesiology, V108, P299, DOI 10.1097/01.anes.0000299433.25179.70
[9]   An Estimation of the Minimum Effective Anesthetic Volume of 2% Lidocaine in Ultrasound-guided Axillary Brachial Plexus Block [J].
O'Donnell, Brian D. ;
Iohom, Gabrielle .
ANESTHESIOLOGY, 2009, 111 (01) :25-29
[10]   The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound [J].
Perlas, Anahi ;
Niazi, Ahtsham ;
McCartney, Colin ;
Chan, Vincent ;
Xu, Daquan ;
Abbas, Sherif .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2006, 31 (05) :445-450