Voltammetric codetection of arsenic(III) and copper(II) in alkaline buffering system with gold nanostar modified electrodes

被引:31
作者
Sullivan, Connor [1 ]
Lu, Dingnan [1 ]
Brack, Eric [2 ]
Drew, Christopher [2 ]
Kurup, Pradeep [1 ]
机构
[1] Univ Massachusetts, Dept Civil & Environm Engn, Lowell, MA 01854 USA
[2] US Army, Natick Soldier Syst Ctr, Natick, MA 01760 USA
基金
美国国家科学基金会;
关键词
Carbon screen printed electrodes; Square wave stripping voltammetry; Gold nanostars; Arsenic; Copper; ANODIC-STRIPPING VOLTAMMETRY; SCREEN-PRINTED ELECTRODES; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL SENSING ARSENIC(III); TRACE AMOUNT; INTERFERENCE; SPECIATION; WATER; AS(III); GROUNDWATER;
D O I
10.1016/j.aca.2020.02.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the challenges preventing rapid, onsite voltammetric detection of arsenic(III) is the overlapping oxidation peak of copper(II). This paper describes a novel methodology for the voltammetric detection of trace levels of arsenic(III) in the presence of high copper(II) concentrations (up to the action level of 1.3 mg L-1 set by the US EPA for drinking water). Square wave stripping voltammetry tests were performed using disposable carbon screen printed electrodes modified with gold nanostars on samples buffered with Britton-Robinson buffer. The optimized parameters for accurate codetection of arsenic(III) and copper(II) were a buffer pH of 9.5, a loading of gold nanostars of 2.39(*)10(-5) nmol per electrode, a deposition voltage of -0.8 V, and a deposition time of 180 s. Based on calibration testing, the limits of detection for arsenic(III) and copper(II) were determined to be 2.9 mu g L-1 and 42.5 mu g L-1, respectively. Furthermore, the linear ranges for arsenic and copper were 0-100 mu g L-1 and 0-250 mu g L-1 with sensitivities of 0.101 mu A (mu g L-1)(-1) and 0.121 mu A (mu g L-1)(-1), respectively. Interference testing was performed with several common ionic species, sodium bicarbonate, sodium chloride, tannic acid, iron(iii) chloride, magnesium chloride, calcium nitrate, and sodium sulfate, with only sodium bicarbonate significantly affecting the response. Validation testing in real-world samples was performed by comparison with graphite furnace atomic absorption spectroscopy. The validation testing demonstrated good accuracy and precision, expressed as percent recovery and relative standard deviation (RSD), respectively, in river water and tap water, with mean percent recoveries of 87.7% (RSD = 4.20%) and 83.2% (RSD = 10.02%), respectively. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 73
页数:11
相关论文
共 58 条
  • [1] Arsenic speciation and toxicity in biological systems
    Akter, KF
    Owens, G
    Davey, DE
    Naidu, R
    [J]. REVIEWS OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, VOL 184, 2005, 184 : 97 - 149
  • [2] Simultaneous electrochemical determination of arsenic, copper, lead and mercury in unpolluted fresh waters using a vibrating gold microwire electrode
    Alves, Georgina M. S.
    Magalhaes, Julia M. C. S.
    Salauen, Pascal
    van den Berg, Constant M. G.
    Soares, Helena M. V. M.
    [J]. ANALYTICA CHIMICA ACTA, 2011, 703 (01) : 1 - 7
  • [3] Immobilization of acetylcholinesterase on screen-printed electrodes: comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides
    Andreescu, S
    Barthelmebs, L
    Marty, JL
    [J]. ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 171 - 180
  • [4] Electrochemical determination of arsenic in natural waters using carbon fiber ultra-microelectrodes modified with gold nanoparticles
    Carrera, Patricio
    Espinoza-Montero, Patricio J.
    Fernandez, Lenys
    Romero, Hugo
    Alvarado, Jose
    [J]. TALANTA, 2017, 166 : 198 - 206
  • [5] OXIDATION-REDUCTION REACTIONS OF METAL-IONS
    CARTER, DE
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1995, 103 : 17 - 19
  • [6] Compton RichardGuy., 2011, ELECTROCHEMICAL DETE
  • [7] ELIMINATION OF COPPER-ZINC INTERMETALLIC INTERFERENCES IN ANODIC-STRIPPING VOLTAMMETRY
    COPELAND, TR
    OSTERYOU.RA
    SKOGERBO.RK
    [J]. ANALYTICAL CHEMISTRY, 1974, 46 (14) : 2093 - 2097
  • [8] Evaluation of copper speciation and water quality factors that affect aqueous copper tasting response
    Cuppett, Jonathan D.
    Duncan, Susan E.
    Dietrich, Andrea M.
    [J]. CHEMICAL SENSES, 2006, 31 (07) : 689 - 697
  • [9] Detection of As(III) via oxidation to As(V) using platinum nanoparticle modified glassy carbon electrodes:: arsenic detection without interference from copper
    Dai, X
    Compton, RG
    [J]. ANALYST, 2006, 131 (04) : 516 - 521
  • [10] Gold nanoparticle modified electrodes show a reduced interference by Cu(II) in the detection of As(III) using anodic stripping voltammetry
    Dai, X
    Compton, RG
    [J]. ELECTROANALYSIS, 2005, 17 (14) : 1325 - 1330